-5-
(1) Adjustment procedure
1) Detach the cover FB, cover RBC, cover RBR and cover RBL.
2) Loosen three hexagonal screws of adjuster. (Make sure that the adjuster moves
freely.)
3) Lift the adjuster in the order of q,e ,w ,r ,q ,...as shown inFigure3.2. Youcan
easily lift the main unit.
4) Leveling the main unit in the front and rear directions.
Put the level vial on the point indicated as a dotted line, and adjust the adjusters q
and wor eand rto set the level vial within –1 division of the scale specified on
the supplied level setting table.
5) Leveling the main unit in the left and right directions.
Put the level vial on the point indicated as an actual line, adjust the adjusters qand
ror wand eto set the level vial within –1 division of the scale specified on the
supplied level setting table.
6) Repeat Steps 4) and 5) to set the level vial on the base bar B within –division of
the scale specified on the supplied level setting table.
7) Lock the adjust nut.
Make sure that the level vial is set within –1 division of the scale specified on the
supplied level setting table while being in lock.
8) Tighten three hexagonal screws of adjuster.