NIOSH APPROVAL INFORMATION
Cautions and Limitations
A- Not for use in atmospheres con-
taining less than 19.5% oxygen.
B- Not for use in atmospheres imme-
diately dangerous to life or health.
C- Do not exceed maximum use con-
centrations established by regula-
tory standards.
D- Airline respirators can be used
only when the respirators are sup-
plied respirable air meeting the
requirements of CGA G-7.1 Grade
D or higher quality.
E- Use only the pressure ranges and
hose lengths specified in the users
instructions.
G- If airflow is cut off, switch to filter
and/or cartridge or canister and
immediately exit to clean air.
H- Follow established cartridge and
canister change schedules or
observe ESLI to ensure that car-
tridges and canisters are replaced
before breakthrough occurs.
J- Failure to properly use and main-
tain this product could result in
injury or death.
L- Follow the manufacturers users
instructions for changing car-
tridges, canisters and/or filters.
M- All approved respirators shall be
selected, fitted, used, and main-
tained in accordance with MSHA,
OSHA, and other applicable regu-
lations.
N- Never substitute, modify, add, or
omit parts. Use only exact replace-
ment parts in the configuration as
specified by the manufacturer.
O- Refer to users instructions, and/or
maintenance manuals for informa-
tion on use and maintenance of
these respirators.
S- Special or critical users instruc-
tions and/or specific limitations
apply. Refer to users instructions
before donning.
S - SPECIAL OR CRITICAL USERS
INSTRUCTIONS
The wearer must comply with the fol-
lowing MSA respirator use limitations:
1. The limitations outlined in the
applicable NIOSH approval.
2. Any applicable limitation contained
in a standard established by a reg-
ulatory agency (such as OSHA)
with jurisdiction over the wearer.
3. Do not wear protection against
substances with poor warning
properties or those which gener-
ate high rates or reaction with sor-
bent material in the canister.
4. If using the Duo-Flo combination
type Abrasi-Blast respirator, make
certain conditions of exposure are
within the limits for which the
device is approved or within the
limits established by MSA for
organic iodides and iodine vapor
(if using the GMR-I-P100 canister).
5. Users must wear suitable protective
clothing and precautions must be
taken so that the respirator is not
worn in atmospheres that may be
harmful to the device (see page 4).
6. This approval applies only when
the device is supplied with res-
pirable air through 8 to 300 feet of
air supply hose within the pres-
sure range of 65 to 85 pounds per
square inch gage.
7. Below 32°F add the following
nosecups to the facepiece:
a. Ultravue nosecups: 471539,
471540, or 471541.
b. Ultra Elite nosecups: 495188,
495189 or 7-901-1. Remove
the 805018 or 7-1384-1 baffle
before installing nosecup. The
baffle must be used if nosecup
is not in place.
8. A maximum of 12 sections of air
supply hose may be used in mak-
ing up the maximum working
length of hose. Each section of
coiled hose, regardless of length,
is considered 50 feet in length
(max.: 6 sections).
RESPIRATOR USE LIMITATIONS
Maximum Use Concentration
Do not exceed ANY of the applicable
maximum use concentrations listed in
the table on the following page.
Mixtures of Contaminants —
NIOSH allows this respirator to be
used for protection against a mixture of
contaminants that are present simulta-
neously or used alternately against one
contaminant then another (using the
same cartridges or filters) if the mixture
meets the following conditions:
Contents/NIOSH Approval Information
TABLE OF CONTENTS
NIOSH APPROVAL INFORMATION ................2
Cautions and Limitations ........................2
SPECIAL USER INSTRUCTIONS ..................2
RESPIRATOR USE LIMITATIONS ..................2
GENERAL DESCRIPTION .......................3
REQUIRED TOOLS ............................4
UNPACKING and INSPECTION ...................5
COMPONENT ASSEMBLY .......................5
DONNING the RESPIRATOR .....................6
USING the RESPIRATOR ....................... 9
Cleaning and Disinfecting ......................11
MAINTAINING the RESPIRATOR .................12
ACCESSORIES ..............................13
ABRASI-BLAST HOOD STYLES and ACCESSORIES . .15
FACEPIECE ASSEMBLIES ......................16
FLOW CONTROL DEVICES .....................17
PRESSURE GAUGE ASSEMBLY .................19
INTERCONNECTING AIR-LINE HOSES ............20
QUICK DISCONNECTS ........................21