3 Unpacking
US 6
BothrespiratorsfromMSAareapprovedbytheNationalInstituteforOccupationalSafetyandHealth(NIOSH)foruseas
anescapedevicefromhazardousatmospheres,includingthosewhichareimmediatelydangeroustolifeorhealth(IDLH).
AnIDLHatmosphereisdefinedas:
“ ... conditions that pose an immediate threat to life or health or conditions that pose an immediate threat of severe
exposure to contaminants, such as radioactive materials, which are likely to have adverse cumulative or delayed effects on
health.” [Title 42 CFR, Part 84, Subpart A, par. 84.2 (q)].”
TransAireEscapeapparatusconsistofacarriercontainingaloose-fittinghood,aflow-controlregulatorandhose
assembly,andanaircylinderandvalveassembly.TheTransAire5MinuteEscapeHoodRespiratoraircylindercontainsa
5-minutesupplyofairatFULLpressure(2216psig).TheTransAire10MinuteEscapeHoodRespiratoraircylinder
containsa10-minutesupplyofairatFULLpressure(3000psig).
TherearesignificantdifferencesbetweenESCAPEapparatus(liketheTransAire)andself-containedbreathingapparatus
(SCBA).
Table 2 Comparison: TransAire Escape Apparatus vs Self-Contained Breathing Apparatus (SCBA)
5-Minute Escape Apparatus 10-Minute Escape Apparatus SCBA
Airflowsfromthecylindertothehood
constantlyuntilthecylinderisempty(5
minutes)
Airflowsfromthecylindertothehood
constantlyuntilthecylinderisempty
(10minutes)
Airflowsfromthecylindertothehood
followinguser'sbreathingrate(30
minutesto60minutes)
Noaudiblealarmwhenthecylinderis
nearlyempty
Noaudiblealarmwhenthecylinderis
nearlyempty
Audiblealarmwarnstheuserthatthe
cylinderisnearlyempty
Loose-fittinghood Loose-fittinghood Tight-fittingpressure-demand
facepiece.Servicetime:30to60
minutes(dependsonthemodel).
Theapparatuscanbewornonthechest,hiporwaist,andmaybecarriedintoorstoredinanareathatmaybepotentially
hazardous.Thehoodisdesignedtobeareservoirofbreathingair.Itisnotdesignedtoprovidesplashprotectionor
withstandexposuretodirectflameorhighheat.
3 Unpacking
Whenyoureceivetheapparatus,inspectittobesureithasnotbeendamagedinshipment.Inmaycases,youwillnotbe
thefirsttohandletheapparatus.So,checkthatitisassembledcorrectly.ChecktheaircylindertobesureitisFULL.The
pressuregaugeshouldread3000psiat70°Fforthe10-minuteunitand2216forthe5-minuteunit.
4 Donning
NOTE: Thecylindermaybewornthreeways:Chest-mounted,hip-mounted,orwaist-mounted.
4.1 Donning the Cylinder and Carrier
1. Chest-Mounted
a. CheckthatthestraphookisattachedtothebottomD-ring.
b. Adjustthecarrierstraptofitcomfortablyoveryourhead.