Nibe HTS 40 User guide

HTS 40
Installatörshandbok
SE Fukt- och temperaturgivare
Installer manual
GB Humidity and temperature sensor
Installateurhandbuch
DE Feuchtigkeits- und Temperaturfühler
Asentajan käsikirja
FI Kosteus- ja lämpötila-anturi
LEK
IHB 2213-7
331693

Svenska
4Viktig information
5Allmänt
5Montering
6Elinkoppling
8Programinställningar
9Tekniska data
English
10Important information
11General
11Mounting
12Electrical connection
14Program settings
15Technical specifications
Deutsch
16Wichtige Informationen
17Allgemeines
18Montage
19Elektrischer Anschluss
21Programmeinstellungen
22Technische Daten
Suomeksi
23Tärkeää
24Yleistä
24Asennus
25Sähköasennukset
27Ohjelman asetukset
27Tekniset tiedot
59Kontaktinformation
3HTS 40
S
Table of Contents
S-serien

Viktig information
SÄKERHETSINFORMATION
Denna handbok beskriver installations- och servicemoment
avsedda att utföras av fackman.
Handboken ska lämnas kvar hos kunden.
Apparaten får användas av barn över 8
år och av personer med fysisk, sensorisk
eller mental funktionsnedsättning samt
av personer som saknar erfarenhet eller
kunskap under förutsättning att de får
handledning eller instruktioner om hur
man använder apparaten på ett säkert
sätt och informeras så att de förstår
eventuella risker. Barn får inte leka med
apparaten. Låt inte barn rengöra eller
underhålla apparaten utan handledning.
Detta är en originalhandbok. Översättning
får inte ske utan godkännande av NIBE.
Med förbehåll för konstruktionsändringar.
©NIBE 2022.
SYMBOLER
OBS!
Denna symbol betyder fara för människa eller ma-
skin.
TÄNK PÅ!
Vid denna symbol finns viktig information om vad
du ska tänka på när du installerar eller servar an-
läggningen.
TIPS!
Vid denna symbol finns tips om hur du kan under-
lätta handhavandet av produkten.
MÄRKNING
Förklaring till symboler som kan förekomma på produktens
etikett/etiketter.
Fara för människa eller maskin.
!
Läs installatörshandboken.
HTS 40 S-serien | SE4
S
Svenska

Allmänt
HTS 40 är ett tillbehör som registrerar luftfuktighet och
temperatur. Det finns olika användningsområden för HTS 40.
Fuktgivare benämns som BM1 i manualen.
ANVÄNDNINGSOMRÅDEN
TÄNK PÅ!
Vilket klimatsystem som HTS 40 ska påverka, ställs
in i huvudproduktens meny 7.2.15.
VÄRME
Begränsa relativ luftfuktighetsnivå (RH) i värmedrift.
•Om menyinställning "Begränsa RH" är vald så påverkas
anläggningen genom parallellförskjutning av värme/kyl-
kurvan.
KYLA
Begränsa relativ luftfuktighetsnivå (RH) i lokalen som kyls.
•Om menyinställning "Begränsa RH" är vald så påverkas
anläggningen genom parallelljustering av värme/kylkur-
van.
Begränsa kylframledning så fuktfällning på rör och kompo-
nenter i kylsystem förhindras.
•Om menyinställning "Förhindra utfällning" är vald så påver-
kas anläggningen genom parallelljustering av kylkurvan.
BEHOVSSTYRD VENTILATION
Vid aktivering av behovsstyrd ventilation tillåts HTS 40 på-
verka ventilationen för att uppnå önskad relativ luftfuktighet.
Om luftfuktigheten inomhus avviker från det inställda värdet
ökas eller minskas tillförseln av luft utifrån beroende på an-
läggningens beräkningar.
•Om behovstyrd ventilation är aktiverad kan man välja hur
mycket frånluftsfläktens hastighet ska påverkas. Tillufts-
fläktens hastighet kommer att påverkas med lika många
procentenheter för att behålla korrekt ventilation.
•Först när den relativa fuktigheten inomhus avviker med
mer än 5% (RH) från inställt värde tillåts förändring av
ventilationen.
•När flera HTS 40 är installerade kommer medelvärdet från
dessa att användas för att styra ventilationen.
TÄNK PÅ!
Felaktiga inställningar av HTS 40 kan medföra
sämre utbyte från installationen samt orsaka
sämre luftkvalitet på grund av dålig ventilation.
FÖRUTSÄTTNINGAR
Det går att ansluta upp till fyra HTS 40 per anläggning och
man kan välja vilken/vilka klimatsystem, 1 till 8, som ska
påverkas.
KOMPATIBLA PRODUKTER
•S735
•S1155
•S1255
•VVM S320
•VVM S325
•SMO S40
INNEHÅLL
Fuktgivare1 st
Fästskruvar2 st
KOMPONENTPLACERING
LEK
AA28-S2AA28
X1
ELKOMPONENTER
Anslutningsplint, spänningsmatningX1
FuktgivarkortAA28
DIP-switchAA28-S2
Montering
HTS 40 ska hängas på vägg.
Montera givaren på lämplig plats, exempelvis en fri innervägg
i hall ca 1,5 m över golv. Det är viktigt att givaren inte hindras
från att mäta korrekt luftfuktighet och rumstemperatur,
exempelvis genom placering i nisch, mellan hyllor, bakom
gardin, ovanför eller nära värmekälla, i drag från ytterdörr
eller i direkt solinstrålning.
OBS!
HTS 40 får inte monteras utomhus.
5HTS 40 S-serien | SE
S

Elinkoppling
OBS!
All elektrisk inkoppling ska ske av behörig elektri-
ker.
Elektrisk installation och ledningsdragning ska ut-
föras enligt gällande nationella bestämmelser.
Inomhusmodulen ska vara spänningslös vid instal-
lation av HTS 40.
•För att undvika störningar får givarkablar till externa an-
slutningar inte förläggas i närheten av starkströmsledning-
ar.
•Minsta area på kommunikations- och givarkablar till extern
anslutning ska vara 0,5 mm² upp till 50 m, till exempel
EKKX, LiYY eller liknande.
ANSLUTNING AV KOMMUNIKATION
Detta tillbehör innehåller ett kretskort (AA28) som ska anslu-
tas direkt till huvudproduktens ingångskort.
Om flera HTS 40 ska anslutas, eller redan finns installerade,
måste de efterföljande korten anslutas i serie med föregåen-
de kort.
Använd kabeltyp LiYY, EKKX eller likvärdig med minst
0,5 mm² kabelarea.
ANSLUTNING AV FLERA HTS 40
2
3
4
5
6
7
8
1
AA28-X1
AA28-X1
1
X1
2 3 4 5 6 7 8
1
X1
2345678
X1
X1
2
3
4
5
6
7
8
1
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
F r inkopplingar mot huvudprodukt se kommande bilder.
Huvudprodukt
HTS 40
HTS 40
Kompatibel huvudprodukt
Se inkopplingen för respektive
huvudprodukt.
ANSLUTNING MELLAN HTS 40 OCH ANDRA
TILLBEHÖR
HTS 40 kan anslutas i serie med andra tillbehör som har ett
AA5-kort. HTS 40 ska alltid anslutas först i serien.
2
3
4
5
6
7
8
1
AA28-X1
1
X1
2 3 4 5 6 7 8
X1
AA5-X4
2
3
4
5
6
7
8
1
A
B
GND
A
B
GND
A
B
GND
A
B
GND
12V
A
B
GND
12V
AA5-X4
ON
1 2 3 4 5 6 7 8
-X9
-X2
24 20212223 1516171819 1011121314 56789 1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
234
-X8
-X4
-X10
-X1
Se inkopplingen för respektive
huvudprodukt.
Kompatibel huvudprodukt
HTS 40
Tillbehör med AA5
BERGVÄRMEPUMPAR
Plint X1 på fuktgivarkortet (AA28) i HTS 40 ansluts till plint
AA2-X30:1-4 i värmepumpen.
S1155/S1255
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Värmepump
AA2-X30
AA28-X1
HTS 40 S-serien | SE6
S

LUFT/VATTENVÄRMEPUMPAR
INOMHUSMODULER
Plint X1 på fuktgivarkortet (AA28) i HTS 40 ansluts till plint
AA2-X30:1-4 i inomhusmodulen.
VVM S320, VVM S325
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Inomhusmodul
AA2-X30
AA28-X1
STYRMODULER
SMO S40
Plint X1 på fuktgivarkortet (AA28) i HTS 40 ansluts till plint
AA100-X9:7-10 i styrmodulen.
HTS 40
+12V
GND
B
A
1
4
3
2
Styrmodul
7
9
10 GND
B
+12V
8 A
AA100-X9
AA28-X1
HTS40
Styrmodul
AA100-X9
AA28-X1
FLERA GIVARE
Om RMU S40 ska anslutas till huvudprodukten, går det att
vidarekoppla från anslutningsplinten (AA28-X1) i HTS 40.
Huvudprodukt HTS40 RMU S40
GND
B
A
+12V
6
7
8
HTS 40RMU S40
B
AA28-X1
5
GND
A
+12V
1 2 3 4
HTS40
RMU S40
AA28-X1
GIVARENS TOLERANSNIVÅ
00 10 20 30 40 50 60 70 80 90 100
±2
±4
±6
±8
±10
RH
(%RH)
Relativ luftfuktighet
(%RH)
Relativ luftfuktighet
(%RH)
ΔRH
(%RH)
DIP-SWITCH
DIP-Switchen (S2) på fuktgivarkortet (AA28) ska ställas in
enligt nedan.
Fuktmätare 2
ON
1 2 3 4
Fuktmätare 1
ON
1 2 3 4
Fuktmätare 4
ON
1 2 3 4
Fuktmätare 3
ON
1 2 3 4
7HTS 40 S-serien | SE
S

Programinställningar
MENYSYSTEMET
Om du inte gör alla inställningar via startguiden, eller behöver
ändra någon inställning, kan du göra detta i menysystemet.
STARTGUIDEN
Startguiden visas vid första uppstart efter värmepumpsin-
stallationen, men finns även i meny 7.7.
TÄNK PÅ!
Se även installatörshandboken för den kompatibla
produkten.
MENY 7.2.1 - LÄGG TILL/TA BORT TILLBEHÖR
Här talar du om för den kompatibla produkten vilka tillbehör
som är installerade.
För att automatiskt identifiera anslutna tillbehör, välj "Sök
tillbehör". Det är även möjligt att manuellt välja tillbehör i
listan.
MENY 1.1 TEMPERATUR
Meny 1.1 - Temperatur
Här gör du temperaturinställningar för anläggningens klimat-
system.
MENY 1.2.4 - BEHOVSSTYRD VENTILATION
Önskad RH%
Inställningsområde: 35 – 75 %
Ytterligare inställningar görs i menyn för ditt ventilationstill-
behör.
MENY 1.3 - RUMSGIVARINSTÄLLNINGAR
Här gör du dina inställningar för rumsgivare och zoner.
Rumsgivarna grupperas per zon.
Här väljer du vilken zon en givare ska tillhöra, det går att
ansluta flera rumsgivare till varje zon. Varje rumsgivare kan
ges ett unikt namn.
Styrning av värme, luftfuktighet och ventilation aktiveras
genom att bocka i respektive alternativ. Vilka alternativ som
visas beror på vilken typ av givare som installeras. Om styr-
ning inte är aktiverad kommer givaren att vara visande.
TÄNK PÅ!
Ett trögt värmesystem som t.ex. golvvärme kan
vara olämpligt att styra med rumsgivare.
MENY 7.2.2 - FRÅNLUFTSMODUL (FLM)
(NIBE FLM/FLM S45)
Lägsta fläkthastighet
Inställningsområde: 45 – 65 %
Högsta fläkthastighet
Inställningsområde: 65 – 85 %
Tidsintervall ändring av fläkthastighet
Inställningsområde: 1 – 60 min
Styrande givare 1 – 2
Inställningsområde: off/HTS 1 – 4
Lägsta fläkthastighet: Här ställer du in minsta tillåtna fläkt-
hastighet under behovsstyrd ventilation.
Högsta fläkthastighet: Här ställer du in högsta tillåtna
fläkthastighet under behovsstyrd ventilation.
Tidsintervall ändring av fläkthastighet: Här ställer du in den
tid det tar för frånluftsmodulen att stegvis öka/minska
fläkthastigheten tills önskad relativ luftfuktighet är uppnådd.
Vid fabriksinställning justeras fläkthastigheten med en pro-
centenhet var tionde minut.
Styrande givare 1 – 2: Här väljer du vilken/vilka frånluftsmo-
duler som ska påverkas av vilken/vilka HTS-enheter. Om två
eller flera HTS-enheter styr en frånluftsmodul justeras
ventilationen efter enheternas medelvärde.
MENY 7.2.15 - FUKTGIVARE (HTS)
Klimatsystem 1 HTS
Inställningsområde: 1 – 4
begr. RH i rummet, syst.
Inställningsområde: av/på
förhindra fuktutfällning, syst.
Inställningsområde: av/på
Upp till fyra fuktmätare (HTS 40) kan installeras.
Här väljer du om ditt/dina system ska begränsa den relativa
luftfuktighetsnivån (RH) i värme- eller kyldrift.
Du kan även välja att begränsa min. kylframledning och be-
räknad kylframledning för att förhindra fuktutfällning på rör
och komponenter i kylsystem.
HTS 40 S-serien | SE8
S

Tekniska data
HTS 40
85x85x35(mm)Plastdistans BxHxD
85x85x14(mm)Mått BxHxD
12 VDC 40 mA
(matas från värmepumpen/inomhusmodul-
en)
Märkspänning
067 538Art nr
9HTS 40 S-serien | SE
S

Important information
SAFETY INFORMATION
This manual describes installation and service procedures
for implementation by specialists.
The manual must be left with the customer.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and under-
stand the hazards involved. Children shall
not play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
This is an original manual. It may not be
translated without the approval of NIBE.
Rights to make any design or technical
modifications are reserved.
©NIBE 2022.
SYMBOLS
NOTE
This symbol indicates danger to person or machine.
Caution
This symbol indicates important information about
what you should consider when installing or servi-
cing the installation.
TIP
This symbol indicates tips on how to facilitate us-
ing the product.
MARKING
Explanation of symbols that may be present on the product’s
label(s).
Danger to person or machine.
!
Read the Installer Manual.
HTS 40 S-serien | GB10
S
English

General
HTS 40 is an accessory that registers humidity and temper-
ature. There are also different areas of use for HTS 40.
Humidity sensor is designated BM1 in the manual.
AREAS OF APPLICATION
Caution
Which climate system will be affected by HTS 40
is set in the main product’s menu 7.2.15.
HEATING
Limit relative humidity level (RH) during heating operation.
•If menu setting "Limit RH" is selected, the installation is
affected via parallel displacement of the heating/cooling
curve.
COOLING
Limit relative humidity level (RH) in the cooled premises.
•If menu setting "Limit RH" is selected, the installation is
affected via parallel adjustment of the heating/cooling
curve.
Limit cooling supply to prevent condensation on pipes and
components in the cooling system.
•If menu setting "Prevent condensation" is selected, the
installation is affected via parallel adjustment of the
cooling curve.
DEMAND-CONTROLLED VENTILATION
When activating demand-controlled ventilation, HTS 40 is
allowed to affect the ventilation in order to achieve the de-
sired relative humidity.
If the humidity indoors differs from the set value, the supply
of air is increased or decreased depending on the installa-
tion’s calculations.
•If demand-controlled ventilation is activated, you can se-
lect how much the exhaust air fan’s speed will be affected.
The supply air fan’s speed will be affected by the same
number of percentage points to maintain the correct
ventilation.
•A change to the ventilation is only permitted when the
relative humidity indoors deviates by more than 5% (RH)
from the set value.
•When several HTS 40 are installed, the average value from
these will be used to control the ventilation.
Caution
Incorrect settings of HTS 40 may lead to reduced
installation efficiency and cause poorer air quality
due to poor ventilation.
CONDITIONS
It possible to connect up to four HTS 40 per installation, and
you can also choose which climate system(s), 1 to 8, will be
affected.
COMPATIBLE PRODUCTS
•S735
•S1155
•S1255
•VVM S320
•VVM S325
•SMO S40
CONTENTS
Humidity sensor1 x
Mounting screws2 x
COMPONENT POSITIONS
LEK
AA28-S2AA28
X1
ELECTRICAL COMPONENTS
Terminal block, power supplyX1
Humidity sensor boardAA28
DIP switchAA28-S2
Mounting
HTS 40 must be hung on a wall.
Install the sensor in a suitable location, for example on a free
internal wall in a hall approx. 1.5 m above the floor. It is im-
portant that the sensor is not prevented from measuring
the correct humidity and room temperature, for example by
being located in a recess, between shelves, behind a curtain,
above or close to a heat source, in a draught from an external
door or in direct sunlight.
NOTE
HTS 40 must not be installed outdoors.
11HTS 40 S-serien | GB
S

Electrical connection
NOTE
All electrical connections must be carried out by
an authorised electrician.
Electrical installation and wiring must be carried
out in accordance with national provisions.
The indoor module must not be powered when in-
stalling HTS 40.
•To prevent interference, sensor cables to external connec-
tions must not be laid close to high voltage cables.
•The minimum area of communication and sensor cables
to external connections must be 0.5 mm² up to 50 m, for
example EKKX, LiYY or equivalent.
CONNECTING COMMUNICATION
This accessory contains a circuit board (AA28) that must
be connected directly to the main product’s input board.
If several HTS 40 are to be connected, or are already in-
stalled, the subsequent boards must be connected in series
with the previous board.
Use cable type LiYY, EKKX or similar with a cable area of at
least 0.5 mm².
CONNECTING SEVERAL HTS 40
2
3
4
5
6
7
8
1
AA28-X1
AA28-X1
1
X1
2 3 4 5 6 7 8
1
X1
2345678
X1
X1
2
3
4
5
6
7
8
1
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
F r inkopplingar mot huvudprodukt se kommande bilder.
Huvudprodukt
HTS 40
HTS 40
Compatible main product
See how to connect each main product.
CONNECTION BETWEEN HTS 40 AND OTHER
ACCESSORIES
HTS 40 can be connected in series with other accessories
that have a AA5 board. HTS 40 has always to be connected
first in the series.
2
3
4
5
6
7
8
1
AA28-X1
1
X1
2 3 4 5 6 7 8
X1
AA5-X4
2
3
4
5
6
7
8
1
A
B
GND
A
B
GND
A
B
GND
A
B
GND
12V
A
B
GND
12V
AA5-X4
ON
1 2 3 4 5 6 7 8
-X9
-X2
24 20212223 1516171819 1011121314 56789 1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
234
-X8
-X4
-X10
-X1
See how to connect each main product.
Compatible main product
HTS 40
Accessory with AA5
GROUND-SOURCE HEAT PUMPS
Terminal block X1 on the humidity sensor board (AA28) in
HTS 40 is connected to terminal block AA2-X30:1-4 in the
heat pump.
S1155/S1255
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Heat pump
AA2-X30
AA28-X1
HTS 40 S-serien | GB12
S

AIR/WATER HEAT PUMPS
INDOOR MODULES
Terminal block X1 on the humidity sensor board (AA28) in
HTS 40 is connected to terminal block AA2-X30:1-4 in the
indoor module.
VVM S320, VVM S325
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Indoor module
AA2-X30
AA28-X1
CONTROL MODULES
SMO S40
Terminal block X1 on the humidity sensor board (AA28) in
HTS 40 is connected to terminal block AA100-X9:7-10 in the
control module.
HTS 40
+12V
GND
B
A
1
4
3
2
Styrmodul
7
9
10 GND
B
+12V
8 A
AA100-X9
AA28-X1
HTS40
Control
module
AA100-X9
AA28-X1
MULTIPLE SENSORS
If RMU S40 is to be connected to the main product, it can
be connected from terminal block (AA28-X1) in HTS 40.
Main product HTS40 RMU S40
GND
B
A
+12V
6
7
8
HTS 40RMU S40
B
AA28-X1
5
GND
A
+12V
1 2 3 4
HTS40
RMU S40
AA28-X1
THE SENSOR'S TOLERANCE LEVEL
00 10 20 30 40 50 60 70 80 90 100
±2
±4
±6
±8
±10
RH
(%RH)
Relativ luftfuktighet
(%RH)
Relative humidity
(%RH)
ΔRH
(%RH)
DIP SWITCH
The DIP switch (S2) on the humidity sensor board (AA28)
must be set as follows.
Humidity sensor 2
ON
1 2 3 4
Humidity sensor 1
ON
1 2 3 4
Humidity sensor 4
ON
1 2 3 4
Humidity sensor 3
ON
1 2 3 4
13HTS 40 S-serien | GB
S

Program settings
MENU SYSTEM
If you do not make all settings via the start guide, or if you
need to change any of the settings, this can be done in the
menu system.
START GUIDE
The start guide appears at first start-up after the heat pump
installation, but can also be found in menu 7.7.
Caution
See also the Installer Manual for the compatible
product.
MENU 7.2.1 - ADD/REMOVE ACCESSORIES
Here, you state which accessories are installed for the
compatible product.
To identify connected accessories automatically, select
"Search for accessories". It is also possible to select accessor-
ies manually from the list.
MENU 1.1 TEMPERATURE
Menu 1.1 - Temperature
Here, you make temperature settings for your installation’s
climate system.
MENU 1.2.4 - DEMAND CONTR. VENTILATION
Desired RH%
Setting range: 35 – 75%
Additional settings are made in the menu for your ventilation
accessories.
MENU 1.3 - ROOM SENSOR SETTINGS
Here, you make your settings for room sensors and zones.
The room sensors are grouped by zone.
Here, you select the zone to which a sensor will belong. It is
possible to connect multiple room sensors to each zone.
Each room sensor can be given a unique name.
The control of heating, humidity and ventilation are activated
by checking each option. Which options are shown depends
on which type of sensor is installed. If control is not activ-
ated, the sensor will be the displaying sensor.
Caution
A slow heating system such as underfloor heating
may be inappropriate for controlling with room
sensors.
MENU 7.2.2 - EXHAUST AIR MODULE (FLM)
(NIBE FLM/FLM S45)
Lowest fan speed
Setting range: 45 – 65%
Highest fan speed
Setting range: 65 – 85%
Time interval change of fan speed
Setting range: 1 – 60 min
Controlling sensor 1 – 2
Setting range: off/HTS 1 – 4
Lowest fan speed: Here, you set the lowest permitted fan
speed under demand-controlled ventilation.
Highest fan speed: Here, you set the highest permitted fan
speed under demand-controlled ventilation.
Time interval change of fan speed: Here, you set the time
it takes for the exhaust air module to increase/decrease the
fan speed step-by-step until the desired relative humidity
is achieved. At the factory setting, the fan speed is adjusted
by one percentage point every ten minutes.
Controlling sensors 1–2: Here, you select which exhaust air
module(s) will be affected by which HTS unit(s). If two or
more HTS units control an exhaust air module, the ventilation
is adjusted according the units’ average value.
MENU 7.2.15 - HUMIDITY SENSOR (HTS)
Climate system 1 HTS
Setting range: 1 – 4
limit RH in the room, syst.
Setting range: on/off
prevent condensation, syst.
Setting range: on/off
Up to four humidity sensors (HTS 40) can be installed.
Here you select whether your system(s) is/are to limit the
relative humidity level (RH) during heating or cooling opera-
tion.
You can also choose to limit min. cooling supply and calcu-
lated cooling supply to prevent condensation on pipes and
components in the cooling system.
HTS 40 S-serien | GB14
S

Technical specifications
HTS 40
85x85x35(mm)Plastic spacer WxHxD
85x85x14(mm)Dimensions WxHxD
12 VDC 40 mA
(supplied from the heat pump/indoor mod-
ule)
Rated voltage
067 538Part No.
15HTS 40 S-serien | GB
S

Wichtige Informationen
SICHERHEITSINFORMATIONEN
In diesem Handbuch werden Installations- und Servicevor-
gänge beschrieben, die von Fachpersonal auszuführen sind.
Dieses Handbuch verbleibt beim Kunden.
Dieses Gerät darf von Kindern ab einem
Alter von 8 Jahren sowie von Personen
mit eingeschränkten physischen, senso-
rischen oder geistigen Fähigkeiten oder
mangelnden Erfahrungen und Wissen nur
dann verwendet werden, wenn diese
unter Aufsicht stehen oder eine Anlei-
tung zur sicheren Benutzung des Geräts
erhalten haben und sich der vorhande-
nen Risiken bewusst sind. Kinder dürfen
nicht mit dem Gerät spielen. Eine Reini-
gung und Wartung durch den Benutzer
darf nicht von Kindern ohne Aufsicht
ausgeführt werden.
Dies ist ein Originalhandbuch. Eine Über-
setzung darf nur nach Genehmigung
durch NIBE stattfinden
Technische Änderungen vorbehalten!
©NIBE 2022.
SYMBOLE
HINWEIS!
Dieses Symbol kennzeichnet eine Gefahr für Per-
sonen und Maschinen.
ACHTUNG!
Dieses Symbol verweist auf wichtige Angaben
dazu, was bei Installation oder Wartung der Anlage
zu beachten ist.
TIPP!
Dieses Symbol kennzeichnet Tipps, die den Um-
gang mit dem Produkt erleichtern.
KENNZEICHNUNG
Erklärung der Symbole, die auf den Produktetiketten abge-
bildet sein können.
Gefahr für Personen und Maschinen.
!
Lesen Sie das Installateurhandbuch.
HTS 40 S-serien | DE16
S
Deutsch

Allgemeines
HTS 40 ist ein Zubehör, das die Feuchtigkeits- und Tempe-
raturwerte erfasst. Es gibt verschiedene Einsatzbereiche
für HTS 40.
Der Feuchtigkeitssensor wird im Handbuch mit BM1 bezeich-
net.
EINSATZBEREICHE
ACHTUNG!
Welches Klimatisierungssystem HTS 40 beeinflus-
sen soll, wird im Menü 7.2.15 des Hauptproduktes
eingestellt.
HEIZUNG
Begrenzung der relativen Luftfeuchtigkeit (RH) im Heizbe-
trieb.
•Bei aktivierter Menüoption für eine RH-Begrenzung wirkt
sich eine Parallelverschiebung der Heiz-/Kühlkurve auf
die Anlage aus.
KÜHLUNG
Begrenzung der relativen Luftfeuchtigkeit (RL) in Bereichen
mit Kühlung.
•Bei aktivierter Menüoption für eine RH-Begrenzung wirkt
sich eine Parallelverschiebung der Heiz-/Kühlkurve auf
die Anlage aus.
Begrenzung der Kühlvorlauftemperatur, um eine Feuchtig-
keitsbildung an Rohren und Komponenten im Kühlsystem
zu verhindern.
•Bei aktivierter Menüoption für eine Kondensationsverhin-
derung wirkt sich eine Parallelverschiebung der Kühlkurve
auf die Anlage aus.
BEDARFSGESTEUERTE VENTILATION
Bei Aktivierung der bedarfsgesteuerten Ventilation darf
HTS 40 die Ventilation beeinflussen, um die gewünschte
relative Luftfeuchtigkeit zu erreichen.
Wenn die Luftfeuchtigkeit im Raum vom eingestellten Wert
abweicht, wird die Zufuhr von Außenluft entsprechend den
Berechnungen der Anlage erhöht oder abgesenkt.
•Wenn die bedarfsgesteuerte Ventilation aktiviert ist, kön-
nen Sie wählen, wie stark die Abluftventilatordrehzahl
beeinflusst werden soll. Die Drehzahl des Zuluftventilators
wird genauso stark verändert, damit eine korrekte Ventila-
tion gewährleistet ist.
•Erst wenn die relative Luftfeuchtigkeit im Raum mehr als
5 % (rel.) vom eingestellten Wert abweicht, wird eine Ände-
rung der Ventilation zugelassen.
•Wenn mehrere HTS 40 installiert sind, wird deren Mittel-
wert zur Regelung der Ventilation verwendet.
ACHTUNG!
Fehlerhafte Einstellungen von HTS 40 können zu
einer schlechteren Ausbeute der Anlage führen
und wegen schlechter Ventilation die Luftqualität
senken.
VORAUSSETZUNGEN
Es können bis zu vier HTS 40 pro Anlage angeschlossen
werden, und Sie können festlegen, welche Klimatisierungs-
systeme, von 1 bis 8, beeinflusst werden sollen.
KOMPATIBLE PRODUKTE
•S735
•S1155
•S1255
•VVM S320
•VVM S325
•SMO S40
INHALT
Feuchtigkeitssensor1 St.
Befestigungsschrauben2 St.
POSITION DER KOMPONENTEN
LEK
AA28-S2AA28
X1
ELEKTRISCHE KOMPONENTEN
Anschlussklemme, SpannungsversorgungX1
FeuchtigkeitssensorplatineAA28
DIP-SchalterAA28-S2
17HTS 40 S-serien | DE
S

Montage
HTS 40 ist an die Wand zu hängen.
Montieren Sie den Sensor an einer geeigneten Position, z.B.
an einer freien Innenwand im Flur ca. 1,5 m über dem Fußbo-
den. Der Sensor darf an der Messung einer korrekten Luft-
feuchtigkeit und Raumtemperatur, z.B. durch die Anbringung
in einer Nische, zwischen Regalen, hinter einer Gardine, über
bzw. in der Nähe einer Wärmequelle, in einem Luftzugbereich
von der Außentür oder in direkter Sonneneinstrahlung, nicht
gehindert werden.
HINWEIS!
HTS 40 darf nicht im Außenbereich montiert wer-
den.
HTS 40 S-serien | DE18
S

Elektrischer Anschluss
HINWEIS!
Alle elektrischen Anschlüsse müssen von einem
befugten Elektriker ausgeführt werden.
Bei der elektrischen Installation und beim Verlegen
der Leitungen sind die geltenden nationalen Vor-
schriften zu berücksichtigen.
Das Innenmodul darf bei der Installation von
HTS 40 nicht mit Spannung versorgt werden.
•Um Störungen zu vermeiden, dürfen Fühlerkabel für exter-
ne Schaltkontakte nicht in der Nähe von Starkstromleitun-
gen verlegt werden.
•Der minimale Kabelquerschnitt der Kommunikations- und
Fühlerkabel für einen externen Schaltkontakt muss 0,5
mm² bis zu 50 m betragen, z.B. EKKX, LiYY o.s.ä.
ANSCHLUSS DER KOMMUNIKATIONSLEITUNG
Dieses Zubehör umfasst eine Platine (AA28), die direkt mit
der Eingangsplatine des Hauptprodukts zu verbinden ist.
Wenn mehrere HTS 40 angeschlossen werden sollen oder
bereits installiert sind, müssen die nächsten Platinen mit
den vorherigen in Reihe geschaltet werden.
Verwenden Sie Kabeltyp LiYY, EKKX oder gleichwertig mit
einem Kabelquerschnitt von 0,5 mm².
ANSCHLUSS MEHRERER HTS 40
2
3
4
5
6
7
8
1
AA28-X1
AA28-X1
1
X1
2 3 4 5 6 7 8
1
X1
2345678
X1
X1
2
3
4
5
6
7
8
1
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
A
B
GND
12V
F r inkopplingar mot huvudprodukt se kommande bilder.
Huvudprodukt
HTS 40
HTS 40
Kompatibles Hauptprodukt
Siehe Anschluss an das jeweilige
Hauptprodukt.
ANSCHLUSSZWISCHENHTS40UNDANDEREM
ZUBEHÖR
HTS 40 kann mit anderem Zubehör in Serie geschaltet wer-
den, das eine AA5-Platine hat. HTS 40 muss in der Serie
stets als Erstes geschaltet werden.
2
3
4
5
6
7
8
1
AA28-X1
1
X1
2 3 4 5 6 7 8
X1
AA5-X4
2
3
4
5
6
7
8
1
A
B
GND
A
B
GND
A
B
GND
A
B
GND
12V
A
B
GND
12V
AA5-X4
ON
1 2 3 4 5 6 7 8
-X9
-X2
24 20212223 1516171819 1011121314 56789 1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
234
-X8
-X4
-X10
-X1
Siehe Anschluss an das jeweilige
Hauptprodukt.
Kompatibles Hauptprodukt
HTS 40
Zubehör mit AA5
ERDWÄRMEPUMPEN
Anschlussklemme X1 an der Feuchtigkeitssensorplatine
(AA28) in HTS 40 wird mit Anschlussklemme AA2-X30:1-4
in der Wärmepumpe verbunden.
S1155/S1255
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Wärmepumpe
AA2-X30
AA28-X1
19HTS 40 S-serien | DE
S

LUFT/WASSER-WÄRMEPUMPEN
INNENEINHEITEN
Anschlussklemme X1 an der Feuchtigkeitssensorplatine
(AA28) in HTS 40 wird mit Anschlussklemme AA2-X30:1-4
in der Inneneinheit verbunden.
VVM S320, VVM S325
HTS 40
Värmepump
AA28-X1
AA2-X30
B
A
GND
+12V
+12V
GND
B
A
1 2 3 4
1
4
3
2
HTS40
Innenmodul
AA2-X30
AA28-X1
REGELGERÄTE
SMO S40
Anschlussklemme X1 an der Feuchtigkeitssensorplatine
(AA28) in HTS 40 wird mit Anschlussklemme AA100-X9:7-
10 im Regelgerät verbunden.
HTS 40
+12V
GND
B
A
1
4
3
2
Styrmodul
7
9
10 GND
B
+12V
8 A
AA100-X9
AA28-X1
HTS40
Steuermodul
AA100-X9
AA28-X1
MEHRERE FÜHLER
Soll RMU S40 mit dem Hauptprodukt verbunden werden, ist
ein Durchschleifen von der Anschlussklemme (AA28-X1) in
HTS 40 möglich.
Hauptprodukt HTS40 RMU S40
GND
B
A
+12V
6
7
8
HTS 40RMU S40
B
AA28-X1
5
GND
A
+12V
1 2 3 4
HTS40
RMU S40
AA28-X1
FÜHLERTOLERANZ
00 10 20 30 40 50 60 70 80 90 100
±2
±4
±6
±8
±10
RH
(%RH)
Relativ luftfuktighet
(%RH)
Relative Luftfeuchtigkeit
(%RH)
ΔRH
(%RH)
DIP-SCHALTER
Der DIP-Schalter (S2) an der Feuchtigkeitssensorplatine
(AA28) ist wie folgt einzustellen.
Feuchtigkeitsmesser
2
ON
1 2 3 4
Feuchtigkeitsmesser
1
ON
1 2 3 4
Feuchtigkeitsmesser
4
ON
1 2 3 4
Feuchtigkeitsmesser
3
ON
1 2 3 4
HTS 40 S-serien | DE20
S
Other manuals for HTS 40
3
Table of contents
Languages:
Other Nibe Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

DOTECH
DOTECH TX3 Series operating instructions

Ropex
Ropex RESISTRON RES-5027 operating instructions

Gemo
Gemo LT102HT quick start guide

Carbolite
Carbolite 201 operating instructions

REGLOPLAS
REGLOPLAS 300L operating instructions

Viessmann
Viessmann VITOSOLIC 100 Installation and service instructions for contractors