Top Panel
A
Blinking Green RS-485 communications is not established.
Once powered is applied, it can take up to
20 seconds to establish communications.
HELPFUL! If communications was
established and subsequently lost,
the LED will stay solid for about 1
minute before it starts blinking.
.5s1s 1s
Repeat
.5s
Solid Green RS-485 communication is established and
module is communicating with thermostat.
BThermistor inputs 1-4 - Connect one thermistor per port (1-
4). When wiring the thermistors, polarity is not observed.
C24V AC input - Connect 24V AC from HVAC transformer or
similar to power the module. Input power is an AC signal so
polarity is not observed.
A
RS-485 port - As shown in the image above, the right three
pins connect to the RS-485 connections in the thermostat.
No connections are made to the leftmost 3 pins. Refer to the
RS-485 Connections section for more information on wiring.
(1) HVAC 10K Sensor Module - (CLI-10K4IN)
(2) 3 Position Screw Down Plug-In Terminal Block (028-0736)
(1) 6 Position Screw Down Plug-In Terminal Block (028-0737)
(1) 6 Position Screw Down Plug-In Terminal Block (028-9352)
(1) Product and Regulatory Insert (009-1703)
Remote Temperature Sensor - Flush Mount (SST-TEMP1)
Outdoor Remote Temperature Sensor (SST-0TEMP1)
PLENOM Remote Sensor - Commercial (CLI-PLEN1C)
PLENOM Remote Sensor - Residential (CLI-PLEN1R)
SLAB Remote Sensor (CLI-SLAB1)
Box Contents
Supported Sensors (available on the Savant Store)
Specifications
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 10% to 90% Rel Humidity (non-condensing)
Power
Input Power 24V AC (19.2 - 28.8V AC)
Max Current Draw .1 amps (rms)
Minimum Supported Release
Climate Config App Version 1.1.2
Regulatory
Safety and
Emissions
FCC Part 15
Contains FCC ID: 2AEHU-MESHTEK-H52
Contains IC: 20059-MESHTEK52
RoHS Compliant
Dimensions and Weights
Height Width Depth Weight
CLI-10K4IN 3.77 inch
(9.58 cm)
3.16 inch
(8.03 cm)
.91 inch
(2.3114 cm)
< 1 lbs
(< .5 kg)
Shipping 6.25 inch
(15.88 cm)
4.8 inch
(12.19 cm)
1.25 inch
(3.175 cm)
< 1 lbs
(< .5 kg)
10K
Status
24VAC
4
3
2
1
CLI-10K4IN-00
S/N:
UID:
SHK180200331
001AAE09C62D2453
A
B
C
~
~
Left Side Panel
A
GndN/C
N/C
N/C B
A
Maximum Wiring Distances
RS-485 Up to 1000 feet (304.8 meters) cumulative.
Power
#24 AWG - 20 feet (6.10 meters)
#20 AWG - 57 feet (17.37 meters)
#18 AWG - 90 feet (27.43 meters)
#16 AWG - 143 feet (43.59 meters)
#14 AWG - 228 feet (69.49 meters)
Sensor Module with Four 10K Thermistor Inputs
Quick Reference Guide
CLI-10K4IN-00 | 009-1798-00 | 190613
Copyright 2019 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
Use the diagram below when wiring the 10K temperature sensors.
Thermistor ConnectionsMaking Connections
Power Connections
RS-485 Connections
Refer to the following documents located on the Savant Customer
Community for additional information.
– Multistat Smart Thermostat Deployment Guide (009-1636)
– Multistat Thermostat with Touchscreen (009-1593)
Additional Information
< 1/8 inch of
bare wire
exposed
When making connections, follow the guidelines set below to ensure a
safe and secure connection.
Use the diagrams below when making the power connections be-
tween the thermostat and the CLI-10K4IN climate module.
Use the diagrams below when making the RS-485 connections be-
tween the thermostat and CLI-10K4IN climate module.
– Power can be daisy-chained between modules.
– The cable lengths vary depending on the size of the wire. See the
specifications table on page 1 for more information.
– Supports a maximum of four sensors per CLI-10K4IN module.
– There is no polarity to the 10K temperature sensors.
– Max cable length = 500 feet (152.4 meters).
– Minimum size wire = 24 AWG.
– A twisted pair is recommended (e.g. Cat 5e/6/7).
– Any 10K type temperature sensor is supported. See the Supported
Sensors section on page 1.
– Climate modules can be daisy-chained to increase the number of
sensors.
– Two or more ports can be combined and the average of these
sensors taken.
1. With a small slotted screwdriver,
turn the screws on the connector
counterclockwise (CCW) until the
silver crimps open enough to slide
a wire into the square slots.
2. Strip back insulation on each wire
to / inch and insert the stripped
wire into the proper connection.
3. Turn the screw clockwise (CW)
until the crimps tighten around
each wire. Tug on each wire a bit
to verify they are secure.
o
G
AUX OUT
AUX IN
RS2
RS1
GND
GND
RX-
RX+
GND
1-WIRE
5V DC
Y2
Y1
W2
W1
RC
RH
TX+
TX-
24C
10K
Status
CLI-10K4IN-00
S/N:
UID:
SHR180600332
001AAE09C6240000
1
2
3
4
24VAC
~
~
+
+
+
+
Power can be
daisy-chained
to other modules
24V AC
from HVAC
o
G
AUX OUT
AUX IN
RS2
RS1
GND
GND
GND
RX-
RX+
GND
1-WIRE
5V DC
Y2
Y1
W2
W1
RC
RH
TX+
(TX+)
TX-
(TX-)
24C
Left Side View
RS-485 Cable
CLI-10K4IN
10K Remote
Sensors
10K
Status
CLI-10K4IN-00
S/N:
UID:
SHR180600332
001AAE09C6240000
1
2
3
4
24VAC ~
~
+
+
+
+
– Max cable length is 1000 feet (304.8 meters).
– Savant recommends using standard RS-485 cable for wire runs.

Other Savant Control Unit manuals

Savant VOM-VP01F User manual

Savant

Savant VOM-VP01F User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant GPM-CP2R20120-21 User manual

Savant

Savant GPM-CP2R20120-21 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant SmartView VOM-SV02 User manual

Savant

Savant SmartView VOM-SV02 User manual

Savant SSC-P008 User manual

Savant

Savant SSC-P008 User manual

Savant Pro Host SVR-5200S-00 User manual

Savant

Savant Pro Host SVR-5200S-00 User manual

Savant ITP-E8000 Series User manual

Savant

Savant ITP-E8000 Series User manual

Savant CLI-1WIRE2 User manual

Savant

Savant CLI-1WIRE2 User manual

Savant Smart Host Rack Mountable User manual

Savant

Savant Smart Host Rack Mountable User manual

Savant CLI-8000 Series User manual

Savant

Savant CLI-8000 Series User manual

Savant VOM-VP02H User manual

Savant

Savant VOM-VP02H User manual

Savant CLI-PTAC1K1 User manual

Savant

Savant CLI-PTAC1K1 User manual

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant SAV-LMP-0300 User manual

Savant

Savant SAV-LMP-0300 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Popular Control Unit manuals by other brands

Ropam elektronik OptimaGSM AP-IP User & installation manual

Ropam elektronik

Ropam elektronik OptimaGSM AP-IP User & installation manual

Supermicro SBI-7147R-S4X user manual

Supermicro

Supermicro SBI-7147R-S4X user manual

Pignology Piglet user guide

Pignology

Pignology Piglet user guide

ETAS ES582.1 user guide

ETAS

ETAS ES582.1 user guide

Arbor Technology EmETXe-a10M0 Quick installation guide

Arbor Technology

Arbor Technology EmETXe-a10M0 Quick installation guide

M-system R7G4FML3-6-DC16A instruction manual

M-system

M-system R7G4FML3-6-DC16A instruction manual

GEM 537 instructions

GEM

GEM 537 instructions

LEGRAND 4 121 71 instructions

LEGRAND

LEGRAND 4 121 71 instructions

MD mXion MZSpro 8A Booster user manual

MD

MD mXion MZSpro 8A Booster user manual

Burkert EPS 21 ATEX 1 234 X operating instructions

Burkert

Burkert EPS 21 ATEX 1 234 X operating instructions

KERAFLO AYLESBURY KAX installation guide

KERAFLO

KERAFLO AYLESBURY KAX installation guide

Hewlett Packard Enterprise aruba SFP+ installation guide

Hewlett Packard Enterprise

Hewlett Packard Enterprise aruba SFP+ installation guide

Midtronics MDX ZIGBEE RADIO user manual

Midtronics

Midtronics MDX ZIGBEE RADIO user manual

Burkert 8691 operating instructions

Burkert

Burkert 8691 operating instructions

Cypress EZ-BLE PRoC AN9684 Getting started

Cypress

Cypress EZ-BLE PRoC AN9684 Getting started

Daikin EKCB07CAV3 installation manual

Daikin

Daikin EKCB07CAV3 installation manual

Hydrolevel Company VXT-24 quick guide

Hydrolevel Company

Hydrolevel Company VXT-24 quick guide

Texas Instruments TRF7960TB user guide

Texas Instruments

Texas Instruments TRF7960TB user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.