manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Savant
  6. •
  7. Control Unit
  8. •
  9. Savant Smart Host Rack Mountable User manual

Savant Smart Host Rack Mountable User manual

SHR-2000-00 | 009-1909-01 | 200123
Copyright 2020 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
1 of 2
Front Panel
Power Status
A B C
APower LED
Green: System has power and is operating
normally.
O: System is not receiving power.
B
Status LED
O: Disconnected from power supply.
Amber: Host is booting/rebooting and is
disconnected from the network.
Green: Connected to the local network and is
assigned an IP Address.
CMounting
Points
Threaded insert for use with optional rack
mounts
Box Contents
(1) Savant® Smart Host Rack Mountable - (SHR-2000-00)
(1) Install Kit (075-0223-xx)
(1) 5V DC 3A Power Supply
with Quick Change AC Adapters ( 025-0216-xx)
(2) 6-pin Screw Down Plug-in Connector Black (028-9352-xx)
(2) 3-pin Screw Down Plug-in Connector Black (028-9351-xx)
(1) Product and Regulatory Insert (009-1781-xx)
Specifications
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 10% to 90% Relative Humidity (non-condensing)
Cooling 10 CFM
Maximum BTU 34.1 BTU/hr
Dimensions and Weights
Height 1.6 in (4.15 cm)
Width 8.5 in (21.50 cm)
Depth 3.7 in (9.33 cm)
Weight Net: 1.4 lb (0.64 kg)
Shipping 2.3 lb (1.05 kg)
Rack Space 1U
Power
Input Power 5V DC 3A
Maximum Power 15 watts
Power over
Ethernet (PoE) IEEE 802.3af
Regulatory
Safety and
Emissions
FCC Part 15 CE C-Tick
RoHS Compliant
Minimum Supported Release
Savant Software da Vinci 9.2
Chassis Installation
The Smart Host can be installed on a solid, flat, level surface such as a
table, cabinet, or shelf. The location should be dry, well ventilated, and
out of direct sunlight.
Rack
The optional RMB-PAVAM2F-xx or RMB-PAVAM2-xx allows two
devices to be mounted side by side. For example a Smart Host can
be mounted next to a PAV-AIM7C. This rack is compatible with all
standard 19-inch National Electrical Manufacturers Association (NEMA)
rack mounts.
The instructions below show the RMB-PAVAM2F-xx, both brackets
install the same way they just face dierent directions.
1. Align the bracket with the Smart Host mounting points.
2. Attach using the screws provided with the bracket.
Network Configuration
To ensure the IP Address will not change due to a power outage, a
static IP Address or DHCP reservation should be configured. Savant
recommends using DHCP reservation within the router. By using this
method, static IP Addresses for all devices can be managed from a
single UI, avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.
Refreshing the IP Connection
After connecting to a new network, changing routers, or if the IP
Address range in the router was changed, the IP connection should be
refreshed. To refresh the IP connection, do one of the following:
–Hot Plug the Ethernet (LAN) Connection
–Cycle power
Savant® Smart Host Rack Mountable
Quick Reference Guide
SHR-2000-00 | 009-1909-01 | 200123
Copyright 2020 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
Control Connections
RS-232 Wiring
Pin 1: No Connection Pin 5: RXD (Receive)
RJ-45 Connector
(Gold pins facing up)
Pin 1 Pin 8
Pin 2: No Connection Pin 6: TXD (Transmit)
Pin 3: No Connection Pin 7: CTS (Flow Control)
Pin 4: GND (Ground) Pin 8: RTS (Flow Control)
IMPORTANT!
–Wire colors are included to identify the pins used for this
connection. Colors shown do not represent any wiring standard.
–When wiring, DO NOT connect any wires within the cable that are
not required for communications.
–Pins 7 & 8 are only required for CTS/RTS handshaking.
–CTS/RTS handshaking is supported for flow control based on the
profile used in the Blueprint configuration.
–RS-422/485 is not supported
–Refer to the RS-232 Conversion to DB9 and RS-422/485 Pin-out
Application Note on the Savant Customer Community for more
information on RJ-45 to DB9 adapters oered by Savant.
Relay Wiring
Both Normally Open
and Normally Closed
outputs are available.
Pin 1: NC
(Normally Closed)
32
1
NC NOC
/ /
Pin 2: Common
Pin 3: NO
(Normally Open)
GPIO - General Purpose Input/Output
–GPIO’s configured
as an output can
be used to trigger
an action within
the system such as
switching a device.
–GPIO configured
as an input can
detect a state
change and trigger
a workflow.
Pin 1: GND (Ground)
32
1
GPIO 1
Standard
GPIO Using
PD Jumper
Gnd
I/O
PD
Pin 2: GPIO 1
Pin 3: PD (Pulldown)
–GPIO pins configured as an input are pulled high to (+12V) during
the boot process. To force the GPIO signal low during a boot-up.
Connect the PD pin to the GPIO pin. This forces the GPIO output to
(< 0.8V) during the processor boot times.
IR Wiring (Infrared)
–Ensure the all IP emitters
are within 15 feet (4.6
meters) from the
controllers location.
–Use of 3rd party
flashing IR emitters
with Talk Back is not
recommended. These
types of emitters can
draw voltage away from
the IR signal that can
degrade IR performance.
Pin 1: IR 1 -
1
IR1
+-+-+-
2
IR2
3
IR3
4 5 6
Use White Stripe
for Positive (+)
Pin 2: IR 1 +
Pin 3: IR 2 -
Pin 4: IR 2 +
Pin 5: IR 3 -
Pin 6: IR 3 +
–IR connections IR4 to IR6 (not shown in diagram) follow the same
wiring as connections IR1 to IR3.
Rear Panel
Reset
Ethernet USB
Audio
RS232-1 RS232-2
1
-+ +
IR
-2+
-3
Relay
CNC NO
4
-+ +
5
-6
-+
GPIO
1G PD
5VDC
IHG
FEDC
BA
AReset
Resets the network settings of the device.
Hold Reset Button for 5 seconds while powered
on to clear network settings. Status LED will
rapidly blink red when reset is complete.
B
USB Not Used
C
Audio
96k / 24 bit fixed volume TOSLink (Optical)
digital audio output. Connect to digital optical
audio input on switcher for using the Audio
Interrupt Service (AIS).
D
RS-232
8-pin RJ-45 female.
Used to transmit and receive serial binary data to
and from serial controllable devices.
Ports 1-2 RS-232 - CTS/RTS handshaking. CTS
RTS handshaking availability is based on the
component profile.
See RS-232 Wiring section for pin-outs.
E
IR
6-pin Screw Down Plug-in Connector. Used to
send IR signals to control devices with an IR input
or IR receiver via an IR flasher (5V tolerant only).
See IR Wiring section for important precautions
regarding IR functionality before making
connections.
F
Relay
3-pin Screw Down Plug-in Connector. See Relay
Wiring section for pin-outs.
Normally Open (NO) / Normally Closed (NC) to
control devices requiring basic on/o operation.
DC Voltage Max: 30V DC 1A
GEthernet
8-pin RJ-45 female.
10/100/1000 Base-T auto negotiating port.
Connecting to this port will disable Wi-Fi
settings.
HGPIO
3-pin Screw Down Plug-in Connector. See GPIO
Wiring section for pin-outs.
GPIO Input - When configured as an input, the
processor will look for a low (<0.8V DC) or a high
(>2.4V DC) state. Minimum 0V DC / Maximum
12V DC.
GPIO Output - When configured as an output,
the port provides a binary output of 0-12V DC
150mA max.
I5V DC
5V DC 3A - Connect included wall wart power
supply between the 5V DC connection and a 115-
240V AC surge protected outlet.
Further Product Information
To view available documentation, detailed product specs, and more:
–Visit the Savant Knowledge tab via the Savant Customer
Community to search all Savant documentation.

This manual suits for next models

1

Other Savant Control Unit manuals

Savant Pro Host SVR-5200S-00 User manual

Savant

Savant Pro Host SVR-5200S-00 User manual

Savant VOM-VP02H User manual

Savant

Savant VOM-VP02H User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant SSC-P008 User manual

Savant

Savant SSC-P008 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant VOM-VP01F User manual

Savant

Savant VOM-VP01F User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant SmartView VOM-SV02 User manual

Savant

Savant SmartView VOM-SV02 User manual

Savant CLI-10K4IN-00 User manual

Savant

Savant CLI-10K4IN-00 User manual

Savant SAV-LMP-0300 User manual

Savant

Savant SAV-LMP-0300 User manual

Savant GPM-CP2R20120-21 User manual

Savant

Savant GPM-CP2R20120-21 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant ITP-E8000 Series User manual

Savant

Savant ITP-E8000 Series User manual

Savant CLI-8000 Series User manual

Savant

Savant CLI-8000 Series User manual

Savant CLI-1WIRE2 User manual

Savant

Savant CLI-1WIRE2 User manual

Savant CLI-PTAC1K1 User manual

Savant

Savant CLI-PTAC1K1 User manual

Popular Control Unit manuals by other brands

Rockwell Automation Allen-Bradley SynchLink 1756-DM Series Design guide

Rockwell Automation

Rockwell Automation Allen-Bradley SynchLink 1756-DM Series Design guide

DeZurik PPE Series Instruction

DeZurik

DeZurik PPE Series Instruction

Renesas RYZ014A Integration guide

Renesas

Renesas RYZ014A Integration guide

TGW CRUZCONTROL GENERATION 2 FOR NBC Installation, operation & maintenance manual

TGW

TGW CRUZCONTROL GENERATION 2 FOR NBC Installation, operation & maintenance manual

Parallel Audio RX8D Operation manual

Parallel Audio

Parallel Audio RX8D Operation manual

BERMAD 700 Series Installation

BERMAD

BERMAD 700 Series Installation

SAFI DN15 manual

SAFI

SAFI DN15 manual

Kutai electronics ATS-380 Operator's manual

Kutai electronics

Kutai electronics ATS-380 Operator's manual

Exodraft EFC21 user guide

Exodraft

Exodraft EFC21 user guide

Aliaxis Friatec Frialen DAV RED SNAP Assembly instruction

Aliaxis

Aliaxis Friatec Frialen DAV RED SNAP Assembly instruction

LOVATO ELECTRIC FF128EP Series Installation, operation and maintenance manual

LOVATO ELECTRIC

LOVATO ELECTRIC FF128EP Series Installation, operation and maintenance manual

Lenze AC Tech POSITIONSERVO quick start guide

Lenze AC Tech

Lenze AC Tech POSITIONSERVO quick start guide

Harvia XENIO CX45J Instructions for installation and use

Harvia

Harvia XENIO CX45J Instructions for installation and use

ASC Global InterCom GSM user manual

ASC Global

ASC Global InterCom GSM user manual

Comau Robotics C5G Instruction handbook

Comau Robotics

Comau Robotics C5G Instruction handbook

DOLD SAFEMASTER C UG 6980 Translation of the original instructions

DOLD

DOLD SAFEMASTER C UG 6980 Translation of the original instructions

Bentel Security OmniaMOD-V2 Installation and use manual

Bentel Security

Bentel Security OmniaMOD-V2 Installation and use manual

Sony CCU-900 Installation and maintenance manual

Sony

Sony CCU-900 Installation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.