Dual 20 Amp Relay Companion Module - QRG | 009-2129-00 1 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220408 Savant.com | 508.683.2500
120V 20A DUAL RELAY
GPM-C2R20120
MODULE INPUT:
LOAD INPUT:
LOAD OUTPUT:
INDOOR USE ONLY
#12-8 AWG Cu ONLY
HOME AUTOMATION EQUIP
IC ID: 10798A-QP2R20120
FCC ID: PUU-QP2R20120
EXXXXXX
YYWW
120VAC 20A/1HP MAX/CHAN
RES, MOTOR
120VAC 60Hz
120VAC 60Hz
LOAD TYPE:
INPUT OUTPUT
AA
INPUT OUTPUT
BB
PAIR
DO NOT
PRESS ON
SCREEN
REMOVE AFTER
INSTALLATION
CIRCUIT POWER
B
A
A
B
C
E
F
G
D
A
Multi-Page LCD screen that can display the following:
–Power draw and energy usage at each output.
–Firmware, Mac Address, and Regulatory Info.
–UID of the Host that the module is communicating with.
–Real-time Bluetooth status connectivity icon.
BManual Load Switches - Toggle to the ON position to switch
the load on. Toggle to AUTO for normal operation. Switch A
controls output A, Switch B controls output B.
C
PAIR Button - The PAIR button is a multi-use button. The
duration that the button is pressed and held determines the
function that gets initiated:
Press and Release - Cycles through the screens available on
the LCD (POWER > ENERGY > INFO 1 > INFO 2).
Press and hold - Press and hold for 2 second to put the
module into pairing mode. Press and hold for 5 seconds to
reset.
DInput Power Connections - Connect the outputs from two
feeder breakers to inputs A and B on the module. See the
Wiring section below.
EOutput Power Connections - Connect output A and output B
to separate loads. See the Wiring section below.
F120V AC Connection - Plugs into the 120V AC bus bar in the
breaker panel. The voltage on this connection powers the
module.
G
Neutral - The model number of the Companion Module
determines the type of neutral connection available:
– Plug-On Neutral - Positioned on the bottom of the module
is a neutral clip that plugs directly onto the neutral bar.
– Pigtail Neutral - A neutral wire protrudes from the
module’s rear and gets wired to the neutral bar in the
breaker panel.
Minimum Supported Release
Savant OS da Vinci 10.1
Electrical and Safety Characteristics
Screw Tighten Torque 3.0 Nm
Wire Type Copper (Cu) only
Pollution Degree 2
Purpose of Control Operating Control, Smart Relay Control
Module or equivalent
Software Class A
Impulse Voltage 2500V
Supported Load Types
Standard Configuration Relay On/O type loads (home automation)
Standards
Wireless Bluetooth 5 Low Energy (BLE)
–2.4 GHz radio frequency
Regulatory
Safety and Emissions
FCC Part 15 UL ICES 003
Contains FCC ID: PUU-QP2R20120
Contains IC: 10798A-QP2R20120
RoHS Compliant
Recommended Load Center Types
All Eaton CH style modules fit into a ¾inch Eaton CH load center.
Power
Input Power
(powers the module) 120V AC (+/- 10%) @ 60 Hz, 0.1A (max)
Input Power
(from feeder breaker) 120V AC @ max power load
Load Power 2400VA max per channel
(20A resistive load / 1 HP max per channel)
Features of Automatic
Action Type 1.B action
Dimensions and Weights
Length Width Height Weight
Module 4.96 inch
(12.6 cm)
1.46 inch
(3.7 cm)
3.39 inch
(8.61 cm)
.54 lbs
(.24 kg)
Shipping 7.48 inch
(19.0 cm)
4.17 inch
(10.60 cm)
1.69 inch
(4.29 cm)
1.0 lbs.
(.45 kg)
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 85% Relative Humidity (non-condensing)
Location Indoor Use Only
Features
–Control capability for loads up to 2400VA per channel.
–All Eaton CH style relay modules are compatible with Eaton CH ¾
inch load centers.
–Dynamic management of loads.
–Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec
sample time.
–Communicates over the air using Bluetooth Low Energy (BLE)
technology.
–Manual load switches, available on the front panel, can toggle
power to the outputs On and O.
–Color LCD display for easy identification and load status.
Dual 20 Amp Relay Companion Module (120V AC) (Supports Eaton CH Load Centers)
Quick Reference and Installation Guide
Specifications
Box Contents Descriptions
(1) Dual 20 Amp Relay Companion Module (Eaton CH)
–GPM-CP2R20120-21 w/Plug-on Neutral -or-
–GPM-C2R20120-21 w/Pigtail
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document)
Construction of Control
Open Type Independently mounted for flush mounting