manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Savant
  6. •
  7. Control Unit
  8. •
  9. Savant SKL-3040-00 User manual

Savant SKL-3040-00 User manual

Other Savant Control Unit manuals

Savant VOM-VP01F User manual

Savant

Savant VOM-VP01F User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant SmartView VOM-SV02 User manual

Savant

Savant SmartView VOM-SV02 User manual

Savant SSC-P008 User manual

Savant

Savant SSC-P008 User manual

Savant CLI-1WIRE2 User manual

Savant

Savant CLI-1WIRE2 User manual

Savant SAV-LMP-0300 User manual

Savant

Savant SAV-LMP-0300 User manual

Savant CLI-PTAC1K1 User manual

Savant

Savant CLI-PTAC1K1 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant GPM-CP2R20120-21 User manual

Savant

Savant GPM-CP2R20120-21 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant CLI-8000 Series User manual

Savant

Savant CLI-8000 Series User manual

Savant VOM-VP02H User manual

Savant

Savant VOM-VP02H User manual

Savant CLI-10K4IN-00 User manual

Savant

Savant CLI-10K4IN-00 User manual

Savant Pro Host SVR-5200S-00 User manual

Savant

Savant Pro Host SVR-5200S-00 User manual

Savant Smart Host Rack Mountable User manual

Savant

Savant Smart Host Rack Mountable User manual

Savant ITP-E8000 Series User manual

Savant

Savant ITP-E8000 Series User manual

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant

Savant IP Audio 125 with Savant Music 2.0 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SKL-3040-00 Quick Reference Guide | 009-1796-00
190228 | Copyright 2019 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
1 of 2
Box Contents
(1x) 40 Keypad Power and Control Module
(5x) 4-pin Screw Down Plug-in Connectors
(1x) Quick Reference Guide (this document)
Additional Required Items
• (1x) 3-Unit Power Module Enclosure (SHA-PEN3C/PWM-ENC3)
per every 3 SKL-3040-00 modules.
• Up to 40x Savant®Echo™ Low-Voltage Keypads per module.
Specifications
Environmental
Temperature 32° to 104° F (0° to 40°C)
Humidity 10% to 90% (non-condensing)
Dimensions and Weights
Height 12.35 (31.37 cm)
Width 3.43 in (8.71 cm)
Depth 2.25 in (5.72 cm) - including connectors
Weight Net: 2.30 lbs (1.04 kg)
Shipping: 3.30 lbs (1.50 kg)
Power
Input 120-240V AC 50/60Hz (7.2 A)
Output Power 24V DC 2A per keypad bus
Maximum Wiring Distance (per keypad bus)
#14 AWG Max = 1000 ft (304.8 m)
Regulatory
RoHS Compliant
Minimum Supported Release
Savant OS da Vinci 9.0
Power Module to Keypad Wiring
Savant® 40 Keypad Power and Control Module [SKL-3040-00]
Quick Reference Guide
Front View
A
Keypad Bus (1-5) - The 40 Keypad Power and Control
Module supports up to 10 low-voltage keypads per bus,
wired in series/daisy-chained with a total of up to 40
keypads per module. (See Keypad Wiring Notes section
for more information).
Keypad Bus Status LED - Green: normal, Amber: Keypad
Address Discovery mode
B
Main Power LED - Green light indicates power is
connected, o indicates power has been removed.
Reset - Using a paperclip or similar, press to reset unit
and discover keypads, press and hold (5 seconds) to
default network settings.
Status LED • No Network Connection - .5 second
blink, 1.5 second o:
• No Host Connection - 2 rapid blinks.
• Host Connected - On (solid green).
• Firmware Upgrade in Progress - long
blink with short o.
D
Ethernet - Connect to network via CAT5/5E/6.
E
When installing 40 Keypad Power and Control Module
into enclosure, use tabs to align. Refer to Keypad Module
Installation section for further details.
C
1.5s0.5s
Repeat
Main Power
Keypad Bus 1
Keypad Bus 2
Keypad Bus 3
Ethernet
Keypad Bus 4
Keypad Bus 5
Reset
Status
A
C
D
E
B
+To keypad pin 1 (power)
—To keypad pin 2 (ground)
A+To keypad pin 3
B-To keypad pin 4
+
-
A+ B-
For Further Product Information:
Scan QR code, or visit the URL below:
http://dealers.savantav.com/portal/redirector.php?id=1165
SKL-3040-00 Quick Reference Guide | 009-1796-00
190228 | Copyright 2019 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
ELECTRIC SHOCK! The 120/240V AC source power poses
an electrical shock hazard that has the potential to cause serious
injury to installers and end users.
IMPORTANT!
• A licensed electrician is required to make AC electrical
connections to the keypad modules. Isolate and turn o power
at the main breaker panel prior to installing any electrical
devices.
• For supply, neutral, and ground connections, use only #14 AWG
or larger solid copper wire.
Prepping Enclosure
Refer to the diagram just below these instruction for reference
1. Remove power at the circuit breaker.
2. Remove the lid from enclosure if one is installed.
3. Turn the captive screw on the AC compartment panel
counterclockwise (CCW) until the screw pops up.
4. Slide the cover up and out away from the enclosure.
Put aside.
5. Remove the two WAGO 6 position push connectors
that were shipped in the AC compartment and set
aside.
6. Remove one of the electrical knockouts at the bottom
of the enclosure and install a 1/2 inch electrical cable
clamp.
7. Remove electrical knockout from module slot 1 and
install 1/2 inch nylon insulating bushing. If installing
more than one module, repeat for slots 2 and 3 as
needed.
Connecting Power
Module
Slot 1
Slide up and
then out
Module
Slot 2
Module
Slot 3
4
3
6
7
Keypad Module Installation
1. Remove the keypad module(s) and corresponding
120/240V AC cable(s) from shipping box.
2. Flip keypad module over so the power supply is
accessible.
3. Plug the keypad module PS to 120/240V AC cable into
the 2 pin connector located on the bottom edge of
the power supply board. The connector is keyed to aid
installation. See diagram below:
Keypad Module Power Supply
Neutral (White)
Hot (Black)
Green (Gnd)
4. Position keypad module over the knockout removed
during step 7 of Prepping Enclosure.
5. Insert the wires through the insulated bushing installed
during step 7 of Prepping Enclosure.
6. Slide the tabs on the bottom of the keypad module
into the slots to the left and right of the electrical
knockout hole.
7. To secure keypad module to enclosure, turn the captive
screw on top of module clockwise (CW).
8. Repeat steps 1 - 8 to install any additional keypad
modules in slots 2 and 3 of enclosure.
With all keypad modules installed, connect the white (neutral),
black (hot), and green (ground) wires from each module to a
120/240V AC circuit. Use the diagram for reference.
1. Verify the 120/240V AC feed from circuit breaker is o.
2. Strip approximately 10 inches of the outer jacketing
from the electrical cable and insert wires through the
electrical clamp installed in step 6 of the Prepping
Enclosure section. Tighten clamp.
3. Using the 6-position WAGO connector mounted to the
green ground wire screwed to the enclosure, connect
all ground wires together.
4. Using one of the WAGO 6-position push connectors
included with the enclosure, connect all the neutral
wires together.
5. Using one of the WAGO 6-position push connectors
supplied with the enclosure, connect all the hot wires
together.
6. Insert all wires into the AC compartment, and reinstall
AC compartment cover.
7. Apply power by switching the breaker at the circuit
breaker box to the On position.
Making Connections
Module
Slot 1
Module
Slot 2
Module
Slot 3
BUSHING
GND
ON PS
GND
ON PS
GND
ON PS
WAG O
CONNECTORS
BUSHING BUSHING
FROM 15 AMP BREAKER
GND
• 4-pin keypad bus is wired straight to pins 1-4 of rst keypad,
with up to 10 keypads daisy-chained per bus, total of up to 40
per module at 1000 ft maximum wiring distance per bus.
• Adding more than 10 keypads per bus is possible, but the
maximum wiring distance per bus must be reduced from 1000
ft down to 500 ft at 20 keypads/bus.
• Keypads sharing a bus must be wired in series (daisy-chained).
Star congurations are not supported.
• Dolphin B Super Crimp connectors or similar are recommended
when splicing keypad wiring.
• For additional wiring diagrams, refer to documentation for the
specic model of low-voltage keypad in use; available on the
Savant Customer Community.
Keypad Wiring Notes