manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Savant
  6. •
  7. Control Unit
  8. •
  9. Savant VOM-VP01F User manual

Savant VOM-VP01F User manual

Other Savant Control Unit manuals

Savant CLI-8000 Series User manual

Savant

Savant CLI-8000 Series User manual

Savant SAV-LMP-0300 User manual

Savant

Savant SAV-LMP-0300 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant Pro Host SVR-5200S-00 User manual

Savant

Savant Pro Host SVR-5200S-00 User manual

Savant CLI-PTAC1K1 User manual

Savant

Savant CLI-PTAC1K1 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant VOM-VP02H User manual

Savant

Savant VOM-VP02H User manual

Savant CLI-1WIRE2 User manual

Savant

Savant CLI-1WIRE2 User manual

Savant Smart Host Rack Mountable User manual

Savant

Savant Smart Host Rack Mountable User manual

Savant SmartView VOM-SV02 User manual

Savant

Savant SmartView VOM-SV02 User manual

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant

Savant IP Audio 125 with Savant Music 2.0 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Savant SKL-3040-00 User manual

Savant

Savant SKL-3040-00 User manual

Savant GPM-CP2R20120-21 User manual

Savant

Savant GPM-CP2R20120-21 User manual

Savant CLI-10K4IN-00 User manual

Savant

Savant CLI-10K4IN-00 User manual

Savant SSC-P008 User manual

Savant

Savant SSC-P008 User manual

Savant ITP-E8000 Series User manual

Savant

Savant ITP-E8000 Series User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

This digital video module (VOM-VP01F) is used in the Savant family of modular matrix
switchers and controllers including the SSP-XXXX platforms. It enables Savant’s
TrueCommand™ (On-Screen Display) technology.
Box Contents
(1) VOM-VP01F with (1) Fiber Protective Cap
(1) HDMI locking cable (CBL-3LHDMI-xx)
(1) Mini DisplayPort to HDMI cable (064-0222-xx)
(1) Quick Reference Guide (this document)
Accessories
(1) HDMI™ over Fiber Receiver (HRX-F001)
(1) Fiber Receiver and Room Controller (FRC-P100)
Specifications
Environmental
Environmental
Refer to the SSP-XXXX chassis specifications.
If applicable, refer to the SSP-1200E, SSP-2400 or SSP-3600 chassis specification
Refer to the SSP-XXXX chassis specifications.
If applicable, refer to the SSP-1200E, SSP-2400 or SSP-3600 chassis specification
Power
Power
Power supplied from the SSP-XXXX chassis.
If applicable, refer to the SSP-1200E, SSP-2400 or SSP-3600 chassis specification
Power supplied from the SSP-XXXX chassis.
If applicable, refer to the SSP-1200E, SSP-2400 or SSP-3600 chassis specification
Compliance
Compliance
Safety and Emissions
FCC Part 15 | CE Mark | C-Tick
RoHS
Compliant
Grounding Procedure
To avoid damage from electrostatic discharge (ESD) when handling modules, use a grounding
strap as shown below:
Observe the following precautions to prevent ESD discharge damage:
1. Use an approved ESD wrist grounding strap or an approved wrist or ankle strap. Ensure
the grounding strap makes good skin contact.
2. Before installing or removing a Savant module, connect the clip end of the ground strap
to the threaded grounding stud on the chassis.
If you plan to return a replaced module to Savant Systems LLC, while wearing the grounded
strap, place the module in the clamshell package that it was originally shipped in or a static
shielding bag to avoid ESD damage to the card.
NOTE: The wrist strap only protects the component from ESD voltages on the body; ESD
voltages on clothing can still cause damage.
Interconnecting Information
After unpacking and installing the module, interconnect the units by referring to the tables and
procedure below.
Front Panel Connectors
Front Panel Connectors
Fiber Output
Fiber output connections to HRX-F001.
Uses SC-terminated OM3 fiber cable 1000 feet (300 meter)
maximum distance.
Graphics Input
HDMI input video connections from the SVR-4100/4100S.
NOTE: The Savant fiber solutions use a single strand of OM3 fiber optic cable per connection.
Savant recommends that at minimum two fiber strands are run and available for redundancy
and expansion.
Fiber Optic Best Practices
Warning: Do not look directly into a fiber optic transceiver or into the ends of fiber optic cables.
Fiber optic transceivers and fiber optic cables connected to transceivers emit laser light that
can damage your eyes.
Warning: Do not stare into the laser beam or view it directly with optical instruments even if
the interface has been disabled.
Caution: Do not bend fiber optic cables beyond their maximum bend radius. Bending the
cables beyond their maximum bend radius can damage the cables and cause problems that
are difficult to diagnose.
Caution: Do not let fiber optic cables hang free from the connector. Do not allow fastened
loops of cables to dangle, which stress the cables at the fastening point.
Fiber Optic Protective Caps
Before plugging a fiber cable into the port on the VOM-VP01F module, you must remove the
protective caps, shown in the next image.
Note: Always keep the protective caps on unplugged fiber connections.
Audio/Video Modules Installation and Removal
This section provides information about installing and removing a VOM-VP01F.
Equipment/Tools Required
The following items are not supplied and are needed to complete the installation:
•Phillips screwdriver
•Module removal tool
Module Installation and Removal
To remove and install audio and video modules from the rear of the Controller, perform the
procedures below.
Caution:Before removing or installing any of the modules, remove power from the
SSP-XXXX chassis by setting the power switch to Off (O) and removing the AC power cord.
Failure to do so will result in damage to the equipment.
Installation
Note: Only install into output slots on chassis.
1. At the rear of the chassis set the power switch to Off (O) and remove the AC power
cord.
2. Align the module edges with the grooves near the bottom of the SSP-XXXX chassis
opening.
3. Slide the module in and push the lower edge of the faceplate until the panel bottoms out
against the rear face of the chassis.
4. Fasten the module to the chassis frame using the two Phillips retaining screws inserted
through the two outer holes.
Removal
1. At the rear of the chassis set the power switch to Off (O) and remove the AC power
cord.
2. Remove the two outer retaining screws.
Retaining
Screw
Retaining
Screw
Slot for
Removal Tool
3. Insert card removal tool into the rectangular slot in the center of the module.
4. Lift up to ensure the tool is hooked behind the faceplate and pull the module gently
towards you.
Note: The Card Removal Tool comes with the chassis.
Video Output Module
(VOM-VP01F)
Quick Reference Guide
009-0487-01
VOM-VP01F
Typical Configuration
Additional Documentation
Additional documentation is available at: SavantSystems.com and navigate as follows
Dealer Login > Knowledge Base.
•Refer to Products > HRX-F001 Quick Reference Guide
•Refer to Products > FRC-P100 Quick Reference Guide
•Click link: RacePoint Blueprint™
Video Output Module
(VOM-VP01F)
Quick Reference Guide
009-0487-01
VOM-VP01F
090612
Copyright © 2012 Savant Systems LLC, SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice