manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxby Lighting
  6. •
  7. Lighting Equipment
  8. •
  9. Saxby Lighting Sight Plus User manual

Saxby Lighting Sight Plus User manual

Battery Replacement
• Switch off the electricity at the mains, both switched and permanent supply.
• Allow batteries to fully discharge then reconnect to supply and allow to
charge for 24 hours.
• Test again for 3 hours, if light does not remain lit change the battery pack
as follows:
- Disconnect from the mains supply both permanent and switched supply.
- Undo two screws at the end of the product then pushing the two quick
release tabs on the one side of the front cover to separate the front cover,
diffuser from product. Keep screws in safe place for refitting later.
- Undo the two screws holding the gear tray and fold down.
- Unplug the battery lead from the lead coming from the PCB. Remove any
cable ties around the cables.
- Remove the battery pack and lift the battery pack out of the fitting. Waste
electrical products should not be disposed of with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
- Replace the battery with a LiFePO4 3.2V 1500mAh only. Use of a
different type of battery will damage the product.
- Write current date on the new battery pack.
- Fit new battery pack in position and re-secure using the screws set aside
earlier. Refit the cable ties in position and then plug battery pack into the
PCB.
- Plug battery pack into circuit board.
- Close and secure gear tray and replace diffuser.
- Restore power and allow to charge for 24 hours.
- Perform full operation check and update test record.
If after routine operation check, the lamp does not remain lit for the three
hour period, a new battery pack may be required.
Live Voltages may be present in this unit even when turned off or when completely disconnected. We recommend cleaning with a soft dry cloth. Do not use
solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before cleaning.
This bulb is protected by a shade. This part must be replaced immediately should the shade become cracked or damaged. This fitting must
not be used without the shade in place.
Replace Cracked Shade
Self-Test Function
This product has self testing function. Visual inspection of
the battery charge LED as below:
www.saxbylighting.com
Instruction manual
97817
Sight Plus Self Test
Care and Safety
Wiring
• This product is double insulated and must not be earthed. If there are any incoming
earth cables, they must be joined together and well insulated with good quality
insulation tape. This is to ensure earth continuity throughout your property.
• Having correctly identified the wiring from your existing light fitting, connect to the
quick fit connection block in the following way, using the supplied link cables
where necessary.
LIGHT FITTING
SUPPLY
INSERT CABLE
PUSH DOWN
Check that...
• You have correctly identified the wires.
• The connections are tight.
PL SL N
LINK CABLE
Maintained (Unswitched) Wiring:
The product is on permanently and comes on during a power failure.
PERMANENT LIVE
NEUTRAL BLUE(N)
BLACK(L)
BROWN(L)
LIGHT FITTING
SUPPLY
Non-Maintained Wiring:
The product is normally off and comes on during a power failure.
PL SL N
PERMANENT LIVE
NEUTRAL BLUE(N)
BLACK(L)
BROWN(L)
LIGHT FITTING
SUPPLY
Maintained (Switched) Wiring:
The product is used as a normal light - switch on/off, light turns on/off.
comes on during a power failure.
PL SL N
PERMANENT LIVE
NEUTRAL BLUE(N)
BLACK(L)
BROWN(L)
SWITCH LIVE
LIGHT FITTINGSUPPLY
Automatic Monthly (Every 30 Days): (in addition to the daily check)
The results of the short duration test shall be recorded.
Automatic Annually (Every 180 & 360 Days): (in addition to the daily check)
The results of the full duration tests shall be recorded.
Manual Testing - Can only be completed under mains conditions
Manual Simulated Power Failure
Manual 30 Day Test
Manual 180/360 Day Test
Manual Fast Test (24 minutes)
Hold test button until you hear 1 beep
Hold test button until you hear 2 beeps
Hold test button until you hear 3 beeps
Hold test button until you hear 4 beeps
Abort Test
Hold the test button for 15 seconds, when you
hear the long sound, the self-test function will
restore the defaults
Fault Indicators:
Red LED flashing once a second, Green LED off,
Beeps twice every minute until fault rectified
Red LED flashing twice a second, Green LED off,
Beeps twice every minute until fault rectified
Battery/Charging Fault
Lamp Fault
Failed Duration Test Red LED solid, Green LED off, Beeps twice every
minute until fault rectified
Performance Indicators:
Normal Operation
Automatic 30 Day Test
Automatic 180/360 Day Test
Manual Simulated Power Failure
Manual 30 Day Test
Manual 180/360 Day Test
Manual Fast Test (24 minutes)
Red LED off, Green LED Solid
Red LED off, Green LED flashing once a second
Red LED off, Green LED flashing twice a second
Red LED off, Green LED off
Red LED off, Green LED four times a second
Red LED off, Green LED flashing once a second
Red LED off, Green LED flashing twice a second
• No loose strands have been left
out of the connection block.
V1 21/07/2021
EU Manufacturer: 1 Gnarrenburg, 27442
UK Manufacturer: BH17 7BY
These products should not be fitted to PIR circuits or short duration timed switches.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
This light fitting is double insulated and does
not require connection to an Earth circuit.
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables away from areas where they may be
at risk from being cut, trapped or damaged
The mains supply cable must have a minimum cross section area of 1.0mm2.
This product is designed to be fitted into a suspended ceiling or wall mounted.
This product has special protection against the ingress of moisture and is IP65 rated.
220-240V~, 50Hz
Supply
Voltage:
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole
luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
Any faulty, broken or damaged modules should be replaced immediately.
Waste electrical products should not be disposed of with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
Do not use Megger or similar high voltage instruments. Due to the fact this
Emergency pack contains electronic components that maybe damaged by high test
voltages, they must be disconnected from the circuit before testing.
To prevent damage to the Emergency pack, do not mix with conventional magnetic
ballasts on the same electrical circuit.
Please read these instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the connections.
This product is not suitable for dimming.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.
Bulb
Type:
4.5W LED (SMD), 6500K
Duration: 3 hours (180 minutes)
Operating Temperature: -20ºC to 45ºC
Maximum Operatin Humidity: 10-90%
This product is rated at IP65.
IP
65
Change over Time: Approximately 1s
Battery Specification: LiFePO4 3.2V 1500mAh
Battery Charge Time: 24 hours
Battery warranty: 2 years
This product is rated at IK08.
IK08
• Undo two screws at the end of the product then pushing the two quick release tabs on the one side of the front cover to
separate the rear casing from product. Keep screws in safe place for refitting later.
• Choose the cable entry holes on the rear casing and drill out the conduit knockouts accordingly.
• This unit can be mounted on the wall or ceiling. After deciding the mounted way accordingly, Using the rear casing as a
template mark the position to drill out the fixing holes. Take care to avoid damaging any concealed wiring and pipes.
The correct fixings should be used, depending upon the surface to be mounted.
• Fix the rear casing into the position with the installation plugs and screws (supplied).
• Pull the cable through the cable entry hole and seal to maintain the IP rating. Wire as detailed Wiring Diagram and plug battery pack into the circuit board.
Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Layout
Installation
Technical data
• Re-clip the front panel in place and re-secure the diffuser using the screws. Ensure that the seal is correctly fitted.
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.
See Wiring diagram
1
4 5
2 3
6 7
Plug battery pack
into the circuit board
Conformity with all relevant UKCA Directive requirements.

This manual suits for next models

1

Other Saxby Lighting Lighting Equipment manuals

Saxby Lighting 81572 User manual

Saxby Lighting

Saxby Lighting 81572 User manual

Saxby Lighting 73666 Manual

Saxby Lighting

Saxby Lighting 73666 Manual

Saxby Lighting HeroPro CCT Emergency User manual

Saxby Lighting

Saxby Lighting HeroPro CCT Emergency User manual

Saxby Lighting Tribeca Wall Manual

Saxby Lighting

Saxby Lighting Tribeca Wall Manual

Saxby Lighting IkonPRO RGB LED Kit User manual

Saxby Lighting

Saxby Lighting IkonPRO RGB LED Kit User manual

Saxby Lighting SHIELDPRO CCT 90376 User manual

Saxby Lighting

Saxby Lighting SHIELDPRO CCT 90376 User manual

Saxby Lighting 74824 Manual

Saxby Lighting

Saxby Lighting 74824 Manual

Saxby Lighting Orion20 User manual

Saxby Lighting

Saxby Lighting Orion20 User manual

Saxby Lighting 13801 User manual

Saxby Lighting

Saxby Lighting 13801 User manual

Saxby Lighting ICARUS PIR 2LT WALL User manual

Saxby Lighting

Saxby Lighting ICARUS PIR 2LT WALL User manual

Saxby Lighting 48700 Manual

Saxby Lighting

Saxby Lighting 48700 Manual

Saxby Lighting Picco User manual

Saxby Lighting

Saxby Lighting Picco User manual

Saxby Lighting 72641 Manual

Saxby Lighting

Saxby Lighting 72641 Manual

Saxby Lighting SMART IKON User manual

Saxby Lighting

Saxby Lighting SMART IKON User manual

Saxby Lighting 78965 User manual

Saxby Lighting

Saxby Lighting 78965 User manual

Saxby Lighting Kios 2 User manual

Saxby Lighting

Saxby Lighting Kios 2 User manual

Saxby Lighting Sight Plus Manual

Saxby Lighting

Saxby Lighting Sight Plus Manual

Saxby Lighting Sight 3 in 1 Manual

Saxby Lighting

Saxby Lighting Sight 3 in 1 Manual

Saxby Lighting Sight ECO User manual

Saxby Lighting

Saxby Lighting Sight ECO User manual

Saxby Lighting 13889 User manual

Saxby Lighting

Saxby Lighting 13889 User manual

Saxby Lighting Albus CCT User manual

Saxby Lighting

Saxby Lighting Albus CCT User manual

Saxby Lighting Odyssey 78667 User manual

Saxby Lighting

Saxby Lighting Odyssey 78667 User manual

Saxby Lighting EL-20079 Manual

Saxby Lighting

Saxby Lighting EL-20079 Manual

Saxby Lighting 43810 Manual

Saxby Lighting

Saxby Lighting 43810 Manual

Popular Lighting Equipment manuals by other brands

LUXMUX Single-SLED ISB1 user manual

LUXMUX

LUXMUX Single-SLED ISB1 user manual

Larson Electronics LED3W-LT-IR instructions

Larson Electronics

Larson Electronics LED3W-LT-IR instructions

Beurer TL 55 Instructions for use

Beurer

Beurer TL 55 Instructions for use

Champlain ACM-192 quick guide

Champlain

Champlain ACM-192 quick guide

Ansult 425-433 operating instructions

Ansult

Ansult 425-433 operating instructions

ProLights Astra Wash19PixIP user manual

ProLights

ProLights Astra Wash19PixIP user manual

Prilux LED PAD AVANT RGBW instruction manual

Prilux

Prilux LED PAD AVANT RGBW instruction manual

RH BECKMAN PENDANT 16 quick start guide

RH

RH BECKMAN PENDANT 16 quick start guide

Procopi BEL 180 Series Instructions for installation and use

Procopi

Procopi BEL 180 Series Instructions for installation and use

Ansult 005579 operating instructions

Ansult

Ansult 005579 operating instructions

Martin LIGHTING DIRECTOR user manual

Martin

Martin LIGHTING DIRECTOR user manual

Sinvest VGE Blue Lagoon AOP COMPACT OZONE & UV-C 75W manual

Sinvest

Sinvest VGE Blue Lagoon AOP COMPACT OZONE & UV-C 75W manual

Whelen Engineering Company WAT GSE Junior Executive installation guide

Whelen Engineering Company

Whelen Engineering Company WAT GSE Junior Executive installation guide

Emos ZY2101 manual

Emos

Emos ZY2101 manual

Craftsman CMMT25166 instruction manual

Craftsman

Craftsman CMMT25166 instruction manual

Pond Technics Copper ElectrolyzeR manual

Pond Technics

Pond Technics Copper ElectrolyzeR manual

Azuro Pools 3EXX0295 Instructions for assembly and use

Azuro Pools

Azuro Pools 3EXX0295 Instructions for assembly and use

Carmanah EG320 user manual

Carmanah

Carmanah EG320 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.