Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Class 1 and must be connected to
an Earth circuit
Please read these instructions carefully before
commencing any work.
Thisunitmustbefittedbyacompetentandqualified
electrician.
Install in accordance with IEE Wiring regulations and
currentBuildingRegulations.
Topreventelectrocutionswitchoffatmainssupply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
pleaseconsultaqualifiedelectrician.
Thislightfittingshouldbeconnectedtoacircuitwitha
30mARCDfitted.
If replacing an existing fitting, make a careful note of
the connections.
Thissystemcontainsnon-replaceablepartsand
cannot be serviced. If damage occurs the part should
be scrapped.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
TheseproductsareratedatIP44.
Theseproductsarenotsuitablefordimming.
Theseproductsarenotsuitableforlocationinornear
a marine or sea environment.
Theentireunitsgethotwhilstonforaperiodoftime.
Specification
Voltage: 240V 50Hz a.c.
Lamp: 30W LED module - 2200lm
IP rating: 44
Layout
Installation
Having correctly identified the wiring from your existing
light fitting and connect to the connection block inside
the product in the following way:
Wiring - 67176
Check that...
• Youhavecorrectlyidentifiedthewires.
• Theconnectionsaretight.
• No loose strands have been left out of the connection
block.
• Planthedesiredlayoutofthisfittingcarefully,
ensuring the cables will reach the distance between
the junction box and the light fitting
• Avoidlocatinganycablesinpositionsthatwould
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged
• Cablesinwallsmustbeprotectedusingsuitable
conduit or plastic trunking.
• Themainssupplycablemusthaveaminimumcross
sectional area of 1.0mm²
• Theseproductshavespecialprotectionagainstthe
ingress of moisture and are IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
• Theshadeontheseproductsishinged.Toopenit,
unscrew the 7 screws around the edge of the shade
and keep them safe for refitting later (Fig.1)
• Thefixingholesarelocatedinthecornersofthewall
back and they need to be punched or drilled through.
Therecommendedholesizeis4.5mm(Fig.2).
• Usingthewallbackasatemplate,markanddrillthe
fixing holes and fit supplied wall plugs (suitable for
masonry only - for other surfaces use appropriate
fixings).Useasharpobjectsuchasascrewdriver
to pierce the rubber grommet in the wall back and
feed the incoming mains supply cable through the
grommet entry hole. Fix the wall back to the wall
using the supplied fixings.
• Wireasdetailedbelow..
NEUTRAL
EARTH(GREEN/YELLOW)
SWITCHEDLIVE
BLUE(N)
GREEN/YELLOW
BROWN(L)
Fig. 2