Unit UPO1000 Series User manual

Quick Guide
UPO1000 Series Digital Phosphor Oscilloscope

Quick Guide UPO1000 Series
2/17
Copyright
Copyright © Uni-Trend Technology (China) Co., Ltd. All rights reserved.
Trademark
UNI-T is the registered trademark of Uni-Trend Technology (China) Co., Ltd.
File Version
20230822-V1.00.0018
Statement
UNI-T products are protected by patent rights in China and foreign countries, including issued and
pending patents.
UNI-T reserves the rights to any product specification and pricing changes.
UNI-T reserves all rights. Licensed software products are properties of Uni-Trend and its subsidiaries
or suppliers, which are protected by national copyright laws and international treaty provisions.
Information in this manual supersedes all previously published versions.
Technical data are subject to change without prior notice.

Quick Guide UPO1000 Series
3/17
1. Safety Requirements
This section contains information and warnings that must be followed to keep the instrument operating
under safety conditions. In addition, user should also follow the common safety procedures.
Safety Precautions
Warning
Please follow the following guidelines to avoid possible electric shock and risk to
personal safety.
Users must follow the following conventional safety precautions in operation,
service and maintenance of this device. UNI-T will not be liable for any personal
safety and property loss caused by the user’s failure to follow the following safety
precautions. This device is designed for professional users and responsible
organizations for measurement purposes.
Do not use this device in any way not specified by the manufacturer. This device is
only for indoor use unless otherwise specified in the product manual.
Safety Statement
Warning
“Warning” indicates the presence of a hazard. It reminds users to pay attention to a
certain operation process, operation method or similar. Personal injury or death
may occur if the rules in the “Warning” statement are not properly executed or
observed. Do not proceed to the next step until you fully understand and meet the
conditions stated in the “Warning” statement.
Caution
“Caution” indicates the presence of a hazard. It reminds users to pay attention to a
certain operation process, operation method or similar. Product damage or loss of
important data may occur if the rules in the “Caution” statement are not properly
executed or observed. Do not proceed to the next step until you fully understand and
meet the conditions stated in the “Caution” statement.
Note
“Note” indicates important information. It reminds users to pay attention to
procedures, methods and conditions, etc. The contents of the “Note” should be
highlighted if necessary.
Safety Sign
Danger
It indicates possible danger of electric shock, which may cause
personal injury or death.
Warning
It indicates that you should be careful to avoid personal injury or
product damage.
Caution
It indicates possible danger, which may cause damage to this device
or other equipment if you fail to follow a certain procedure or
condition. If the “Caution” sign is present, all conditions must be met
before you proceed to operation.
Note
It indicates potential problems, which may cause failure of this device
if you fail to follow a certain procedure or condition. If the “Note” sign
is present, all conditions must be met before this device will function
properly.
AC
Alternating current of device. Please check the region’s voltage range.
DC
Direct current device. Please check the region’s voltage range.

Quick Guide UPO1000 Series
4/17
Grounding
Frame and chassis grounding terminal
Grounding
Protective grounding terminal
Grounding
Measurement grounding terminal
OFF
Main power off
ON
Main power on
Power
Supply
Standby power supply: when the power switch is turned off, this
device is not completely disconnected from the AC power supply.
CAT I
Secondary electrical circuit connected to wall sockets through transformers or
similar equipment, such as electronic instruments and electronic equipment;
electronic equipment with protective measures, and any high-voltage and
low-voltage circuits, such as the copier in the office.
CAT II
CATII: Primary electrical circuit of the electrical equipment connected to the indoor
socket via the power cord, such as mobile tools, home appliances, etc. Household
appliances, portable tools (e.g. electric drill), household sockets, sockets more than
10 meters away from CAT III circuit or sockets more than 20 meters away from CAT
IV circuit.
CAT III
Primary circuit of large equipment directly connected to the distribution board and
circuit between the distribution board and the socket (three-phase distributor
circuit includes a single commercial lighting circuit). Fixed equipment, such as
multi-phase motor and multi-phase fuse box; lighting equipment and lines inside
large buildings; machine tools and power distribution boards at industrial sites
(workshops).
CAT IV
Three-phase public power unit and outdoor power supply line equipment.
Equipment designed to “initial connection”, such as power distribution system of
power station, power instrument, front-end overload protection, and any outdoor
transmission line.
Certific
ation
CE indicates a registered trademark of EU.
Certific
ation
UKCA indicates a registered trademark of the United Kingdom.
Certific
ation
It conforms to UL STD 61010-1, 61010-2-030, CSA STD C22.2 No.61010-1 and
61010-2-030.
Waste
This product complies with the marking requirements of WEEE Directive
(2002/96/EC). This additional label indicates that this electrical / electronic product
must not be discarded in household waste.
EFUP
This environment-friendly use period (EFUP) mark indicates that dangerous or toxic
substances will not leak or cause damage within this indicated time period. The
environment-friendly use period of this product is 40 years, during which it can be
used safely. Upon expiration of this period, it should enter the recycling system.
Safety Requirements
Warning

Quick Guide UPO1000 Series
5/17
Preparation
before use
Please connect this device to AC power supply with the power cable provided;
The AC input voltage of the line reaches the rated value of this device. See the
product manual for specific rated value.
The line voltage switch of this device matches the line voltage;
The line voltage of the line fuse of this device is correct;
Not use to measure the main circuit.
Check all
terminal rated
values
Please check all rated values and marking instructions on the product to avoid fire
and impact of excessive current. Please consult the product manual for detailed
rated values before connection.
Use the power
cord properly
You can only use the special power cord for the instrument approved by the local
and state standards. Please check whether the insulation layer of the cord is
damaged or the cord is exposed, and test whether the cord is conductive. If the cord
is damaged, please replace it before using the instrument.
Instrument
Grounding
To avoid electric shock, the grounding conductor must be connected to the ground.
This product is grounded through the grounding conductor of the power supply.
Please be sure to ground this product before it is powered on.
AC power supply
Please use the AC power supply specified for this device. Please use the power cord
approved by your country and confirm that the insulation layer is not damaged.
Electrostatic
prevention
This device may be damaged by static electricity, so it should be tested in the
anti-static area if possible. Before the power cable is connected to this device, the
internal and external conductors should be grounded briefly to release static
electricity. The protection grade of this device is 4KV for contact discharge and 8KV
for air discharge.
Measurement
accessories
Measurement accessories are of lower class, which are definitely not applicable to
main power supply measurement, CAT II, CAT III or CAT IV circuit measurement.
Probe assemblies and accessories within the scope of IEC 61010-031 and current
sensors within the scope of IEC 61010-2-032 shall meet their requirements.
Use the input /
output port of
this device
properly
Please use the input / output ports provided by this device in a properly manner. Do
not load any input signal at the output port of this device. Do not load any signal that
does not reach the rated value at the input port of this device. The probe or other
connection accessories should be effectively grounded to avoid product damage or
abnormal function. Please refer to the product manual for the rated value of the
input / output port of this device.
Power fuse
Please use power fuse of specified specification. If the fuse needs to be replaced, it
must be replaced with another one that meets the specified specifications by the
maintenance personnel authorized by UNI-T.
Disassembly and
cleaning
There are no components available to operators inside. Do not remove the
protective cover.
Maintenance must be carried out by qualified personnel.
Service
environment
This device should be used indoors in a clean and dry environment with ambient
temperature from 0 ℃- 40 ℃.
Do not use this device in explosive, dusty or humid air.
Do not operate
in humid
environment
Do not use this device in a humid environment to avoid the risk of internal short
circuit or electric shock.
Do not operate
in flammable
and explosive
environment
Do not use this device in a flammable and explosive environment to avoid product
damage or personal injury.
Caution

Quick Guide UPO1000 Series
6/17
Abnormality
If this device may be faulty, please contact the authorized maintenance personnel of
UNI-T for testing. Any maintenance, adjustment or parts replacement must be done
by the relevant personnel of UNI-T.
Cooling
Do not block the ventilation holes at the side and back of this device;
Do not allow any external objects to enter this device via ventilation holes;
Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides,
front and back of this device.
Safe
transportation
Please transport this device safely to prevent it from sliding, which may damage the
buttons, knobs or interfaces on the instrument panel.
Proper
ventilation
Poor ventilation will cause the device temperature to rise, thus causing damage to
this device. Please keep proper ventilation during use, and regularly check the vents
and fans.
Keep clean and
dry
Please take actions to avoid dust or moisture in the air affecting the performance of
this device. Please keep the product surface clean and dry.
Note
Calibration
The recommended calibration period is one year. Calibration should only be carried
out by qualified personnel.
1.1 Environmental Requirements
This instrument is suitable for the following environment:
Indoor use
Pollution degree 2
In operating: altitude lower than 3000 meters; in non-operating: altitude lower than 15000 meters
Unless otherwise specified, operating temperature is 0 to +40℃; storage temperature is -20 to﹢70℃
In operating, humidity temperature below to +35℃, ≤90%relative humidity;
In non-operating, humidity temperature +35℃to +40℃, ≤60%relative humidity
There are ventilation opening on the rear panel and side panel of the instrument. So please keep the air
flowing through the vents of the instrument housing. To prevent excessive dust from blocking the vents,
please clean the instrument housing regularly. The housing is not waterproof, please disconnect the power
supply first and then wipe the housing with a dry cloth or a slightly moistened soft cloth.
1.2 Connecting Power Supply
The specification of input AC power.
Voltage Range
Frequency
Maximum Power
100-240 VAC (fluctuant: ±10%)
50/60 Hz
75 W
100-120 VAC (fluctuant: ±10%)
400 Hz
Please use the attached power cable to connect to the power port.
Connecting to service cable
This instrument is a Class I safety product. The supplied power lead has good performance in terms of case
ground. This spectrum analyzer is equipped with a three-prong power cable that meets international safety
standards. It provides good case grounding performance for the specification of your country or region.

Quick Guide UPO1000 Series
7/17
Please install AC power cable as follows.
Ensure the power cable is in a good condition.
Leave enough space for connecting the power cord.
Plug the attached three-prong power cable into a well-grounded power socket.
1.3 Electrostatic Protection
Electrostatic discharge may cause damage to component. Components can be damaged invisibly by
electrostatic discharge during transportation, storage and use.
The following measure can reduce the damage of electrostatic discharge:
Testing in anti-static area as far as possible.
Before connecting the power cable to the instrument, inner and outer conductors of the instrument
should be briefly grounded to discharge static electricity.
Ensure all the instruments are properly grounded to prevent the accumulation of static.

Quick Guide UPO1000 Series
8/17
2. Introduction of UPO1000
UPO1000 series digital phosphor oscilloscope includes three models.
Model
Analog Bandwidth
Analog Channel
Sampling Rate
UPO1204
200 MHz
4
2 GSa/s
UPO1104
100 MHz
4
2 GSa/s
UPO1054
50 MHz
4
2 GSa/s
UPO1000 series digital phosphor oscilloscope adopts UNI-T 3D technique Ultra Phosphor 2.0 with new
appearance upgrade and the function of deep storage, high waveform capture rate, real-time
waveform recording and playback and 256-level grayscale display.
The series is equipped with three levels of bandwidth of 50 MHz/100 MHz/200 MHz, real-time sampling
rate up to 2 GSa/s. The whole series are equipped with 4 channels, the maximum storage depth is
56Mpts, up to 500,000wfms/s in Fast Acquire mode. Hardware real-time waveform uninterrupted
recording and waveform analysis up to 120,000 waveform frames; support DVM module, rich trigger
and bus decoding functions, and support full memory hardware real-time decoding.
It widely used in many fields, including communication, semiconductor, computer, IC design,
instrumentation, industrial electronics, consumer electronics, automotive electronics, field
maintenance and R&D/education.

Quick Guide UPO1000 Series
9/17
3. Getting Started Guide
This chapter is to introduce on using the oscilloscope for the first time, the front and rear panels, the user
interface, as well as the built-in help system.
3.1 General Inspection
It is recommended to inspect the instrument follow the steps below before using the UPO1000 series for
the first time.
(1) Check for Damages caused by Transport
If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T
distributor of this product immediately.
(2) Check Attachment
Please check appendix for the list of accessories. If any of the accessories are missing or damaged,
please contact UNI-T or local distributors of this product.
(3) Machine Inspection
If the instrument appears to be damaged, not working properly, or has failed the functionality test,
please contact UNI-T or local distributors of this product.
If the equipment is damaged due to shipping, please keep the packaging and notify both the
transportation department and UNI-T distributors, UNI-T will arrange maintenance or replacement.
3.2 Before Use
To perform a quick verification of the instrument’s normal operations, please follow the steps below.
(1) Connecting to the Power Supply
AC power specification of UPO1000 series digital storage oscilloscope refers to Connecting Power
Supply section. Use the assembled power line or other power line that meets the local country
standards to connect the oscilloscope. The power soft indicator in the left bottom on front
panel is extinguished and this soft switch key is no-effect when the power switch on rear panel is not
opened. The power soft indicator in the left bottom on front panel is illuminated with red and
then press the soft switch key to enable the oscilloscope.
(2) Boot Check
Press the soft power key and the indicator should change from red to green. The oscilloscope
will show a boot animation, and then enter the normal interface.
(3) Connecting Probe
Use BNC of the port to connect to BNC of CH1 of the oscilloscope. Connecting the probe to the “probe
compensation signal connection clip” and connecting the ground alligator clip to the “ground terminal”
under the “probe compensation signal connection clip”. The output of probe compensation signal
connection clip is the amplitude about 3Vpp and the frequency defaults to 1 kHz.

Quick Guide UPO1000 Series
10/17
Figure 4-1 Probe Compensation Signal Connection Clip and Ground Terminal
(4) Function Check
Press the AUTO key, a 3 Vpp, 1 kHz square wave should appear on the screen. Repeat step 3 to check all
channels.
(5) Probe Compensation
When the probe is connected to any input channel for the first time, this step might be adjusted to
match the probe and the input channel. Probes that are not compensated may lead to measurement
errors or mistake. Please follow the following steps.
Set the attenuation coefficient in the probe menu to 10x and the switch of the probe at 10x, and
connecting the probe of the oscilloscope to CH1. If use the probe’s hook head, make sure it stably
touch to the probe. Connecting the probe to the “probe compensation signal connection clip” and
connecting the ground alligator clip to the “ground terminal” under the “probe compensation signal
connection clip”. Open CH1 and press the AUTO key.
View the displayed waveform, as shown in Figure 4-2.
Excessive Compensation Correct Compensation Insufficient Compensation
Figure 4-2 Compensating Calibration of Probe
If the displayed waveform is look like the above “Insufficient Compensation” or “Excessive
Compensation”, use a non-metallic screwdriver to adjust the probe’s variable capacitance until the
display matches the "Correct compensation" waveform.
Warning:To avoid electric shock when using the probe to measure high voltage, please ensure that the
probe insulation is in good condition and avoid physical contact with any metallic part of the probe.
Ground terminal
Probe compensation
signal connection clip

Quick Guide UPO1000 Series
11/17
4. Front Panel
Figure 3 Front Panel
Table 1 Function Key of Front Panel
No,
Function Key
No,
Function Key
1
Screen display area
9
Horizontal control area
(HORIZONTAL)
2
Multipurpose rotary knob
10
Analog channel input port
3
Navigation function area
11
Vertical control area (VERTICAL)
4
Functional menu key
12
Menu control soft key
5
Run/Stop control key
13
Probe compensation signal
connection clip and ground
terminal
6
Single trigger control key
14
USB HOST port
7
Auto setting control key
15
Power switch soft key
8
Trigger control area (TRIGGER)
8
4
1
2
3
10
13
9
○
13
11
12
14
15
5
7
6

Quick Guide UPO1000 Series
12/17
5. Rear Panel
Figure 4 Rear Panel
Table 1 Function Key of Rear Panel
No,
Function Key
No,
Function Key
1
EXT Trig
5
Power switch
2
AUX Out (output port) and
arbitrary waveform signal output
6
AC Power input socket,refer to
Connecting Power Supply
3
LAN interface
7
Safety lock
4
USB Device interface

Quick Guide UPO1000 Series
13/17
6. User Interface
Figure 5 User Interface
Table 3 Icon of User Interface
No.
Description
No.
Description
1
Trigger status
9
Next page /System time/USB
icon/LAN icon
2
Horizontal time base
10
CH4 state label
3
Horizontal offset
11
CH3 state label
4
Waveform indicator
12
CH2 state label
5
Trigger position
13
CH1 state label
6
Sampling rate and Storage depth
14
Analog channel label and waveform
7
Trigger information
15
Time base scale, volts/div scale
popup
8
Operation menu
1
2
3
4
6
7
5
8
9
13
14
12
11
10
15

7. Menu Symbol
Press any soft key to activate the corresponding menu, the following symbol may display in the menu.
represents use the multipurpose rotary knob to select the parameter and adjust the parameter
value.
represents the current menu have several options.
represents the current menu has a next menu.
represents use numerical keyboard to input the parameter.
represents the current page can be page up and page down.
represents use the multipurpose rotary knob or press the in the Navigation bar to open the
numerical keyboard and adjust the parameter value.

Quick Guide UPO1000 Series
15/17
8. Remote Control
UPO1000 series digital phosphor oscilloscope supports communicate with computer through USB
interface and LAN interface, so as to realize remote control. Remote control is based on SCPI (Standard
Commands for Programmable Instruments) to realize.
UPO1000 series digital phosphor oscilloscope supports three methods for remote control.
(1) User-defined programming
User can program control the instrument by SCPI. The details can refer to UPO Series Programming
Manual.
(2) PC software (instrument manager)
User can send the command via PC software to remote control the instrument. It is recommended to
use UNI-T PC software instrument manager.
You can log in UNI-T official website (https://www.uni-trend.com) to download the software.
Operation Steps
Setup the communication between instrument and computer
Running the instrument manager and search instrument source
Open remote command control panel to send command. This instrument supports
communication with the computer via USB, LAN and RS232 interface, so as to realize remote
control. Remote control is based on SCPI to realize.
(3) Web Control
Open Web via IP, use user name and password to log in and remote control the instrument. It supports
remote control the instrument by using local network or outer network.

Quick Guide UPO1000 Series
16/17
9. Troubleshooting
(1) When press the button, the oscilloscope is black screen.
a. Check whether the power is correctly connected, power supply is normal or not.
b. Check whether the power switch is really on, press the front panel power key and confirm green
light and a relay sound is present.
c. If there is a relay sound, it indicates that the oscilloscope starts normally. Try the following
operations: press the DEFAULT key, then press F1, if device returns to normal, it means backlight
brightness is too low.
d. After completing the above steps, restart the oscilloscope.
e. If you still cannot use this product normally, please contact UNI-T.
(2) After signal acquisition, the waveform of the signal does not appear in picture.
a. Check whether the two ends of BNC line are connected properly.
b. Check whether the output channel of signal source is opened.
c. Check whether the intput channel of the oscilloscope is opened.
d. Check whether the signal in signal source has DC offset.
e. Plug out the input signal, check whether the baseline is in the center of the screen (if the baseline
is not in the center of the screen, it should be self-calibration.)
f. If you still cannot use this product normally, please contact UNI-T.
(3) The measured voltage amplitude value is 10 times larger or 10 times smaller than the actual value:
Check whether the channel probe attenuation coefficient settings are consistent with the used probe
attenuation rate.
(4) There is a waveform display but not stable.
a. Check the trigger settings in trigger menu whether is consistent with the actual signal input
channel.
b. Check the trigger type: general signals should use “Edge” trigger. Only when the proper trigger
type is used, the waveform can be displayed stably.
c. Try to change trigger coupling to HF rejection or LF rejection to filter out he high-frequency or
low-frequency noise that interfere the trigger.
(5) No waveform display after press RUN/STOP key.
a. Check whether the trigger mode in the trigger menu is on “Normal” or “Single” and whether the
trigger level exceeds the waveform range.
b. If it exceeds, set the trigger level to the middle or set the mode to “Auto”.
c. The above settings can be completed automatically by pressing AUTO key.
(6) Waveform refresh is very slow.
a. Check whether the acquisition method is average and the average times are large.
b. Check whether the storage depth is the maximum.
c. Check whether the trigger hold-off time is greater.
d. Check whether the trigger is normal and the current time base is slow.
e. All he above reasons will lead to slow refresh of waveform. It is recommended to restore the
factory settings, and the waveform can be refreshed normally.

Quick Guide UPO1000 Series
17/17
10. Appendix Contact Us
If the use of this product has caused any inconvenience, if you in mainland China you can contact UNI-T
company directly.
Service support: 8am to 5.30pm (UTC+8), Monday to Friday or via email. Our email address is
infosh@uni-trend.com.cn
For product support outside mainland China, please contact your local UNI-T distributor or sales center.
Many UNI-T products have the option of extending the warranty and calibration period, please contact
your local UNI-T dealer or sales center.
To obtain the address list of our service centers, please visit our website at URL:
http://www.uni-trend.com
Other manuals for UPO1000 Series
1
This manual suits for next models
3
Table of contents
Other Unit Test Equipment manuals

Unit
Unit UT673A User manual

Unit
Unit UTD1025CL User manual

Unit
Unit UTL8200 Series User manual

Unit
Unit UT521 User manual

Unit
Unit utd2000 User manual

Unit
Unit UPO1000 Series User manual

Unit
Unit UT521 User manual

Unit
Unit UPO1000CS Series User manual

Unit
Unit UT581 User manual

Unit
Unit UTD1000 Series User manual