Installation and Technical Information
BEGA
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
Replacement Parts
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2018
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
LED Facade Floodlight 77 153
Tools Required:
5mm hex key
Adjustable wrench
Weight: 12.1 lbs.
Dimensions
A: 39-3/8 ”
B: 4-1/2 ”
C: 2-1/4 ”
Relamping/Maintenance
No relamping required.
Lamp: 39.2W LED
77 153
7/10/2018
Page 1 of 2
Description
LED (3000K) (2x)
LED (4000K) (2x)
Driver (120-277V)
Part No
LED-0612/830
LED-0612/840
75969-02
Notice to Installer for 77 153:
1. See page 2 for specic product safety warnings.
2. Integral LED module and driver provided by BEGA within luminaire housing.
3. Leader cable must be secured to a wet location rated junction box with UL Listed or CSA
Certied liquid tight cord grip suitable for exible leader cable provided. Outer diameter
of the 5-wire 77 284 leader cable: 0.35” - 0.38”.
77 153 - installation:
1. Loosen (2) 5mm captive hex screws and detach mounting base from luminaire.
2. Attach base to nished mounting surface with (2) screws and washers (by others).
3. Adjust aiming, if desired, by removing (2) hex nuts and washers to detach mounting base
from mounting plate. Move mounting base on ribbed track of mounting plate to desired
aiming location. Reattach mounting base to mounting plate with hex nuts.
4. Remove end cap from 5-pin connector and connect luminaire cables to leader and/or
jumper cables. Leave endcap on 5-pin connector if not attached to either a leader or
jumper cable.
5. Direct connected cables through openings on either end of mounting base and replace
luminaire. Tighten (2) hex screws to secure.
6. Make leader cable wiring connections in wet location wiring box (by others):
MAIN VOLTAGE SUPPLY WIRE TO BLACK LEADER WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LEADER WIRE
GREEN GROUND WIRE TO GREEN LEADER WIRE
Dimming (if applicable):
DIMMING CONTROL WIRE (+) TO POSITIVE LEADER DIM WIRE
DIMMING CONTROL WIRE (-) TO NEGATIVE LEADER DIM WIRE
Figure 1:
Mounting Base
Mounting Plate
Luminaire