Installation
Aerada™1200 Series
CS Faucet
S53-315 Battery Operated
Capacitive Sensing Faucet
Centershank with 4-inch Trim Plate
(Optional: 8-inch or no Trim Plate)
215-1582 Rev. H; ECN 18-02-003
© 2018 Bradley
1 of 7 6/13/2018
P.O. Box 309
Menomonee Falls, WI 53052 USA
800-BRADLEY (800 272 3539
bradleycorp.com
IMPORTANT!
Read this entire installation manual to ensure proper installation, then file
this manual with the owner or maintenance department. Compliance and
conformity to local codes and ordinances is the responsibility of the installer.
Pressurized plumbing fixtures must be installed in accordance with
manufacturer’s recommendations. The supply piping to these devices must
be securely anchored to the building structure to prevent unnecessary
movement of the installed device when operated by the user. Use extreme
caution when installing the device to prevent damage to the exposed
significant surface.
Separate parts from packaging and make sure all parts are accounted for
before discarding any packaging material. If any parts are missing, do not
begin installation until you obtain the missing parts.
Flush water supply lines before making connections. DO NOT use pipe dope
on any faucet or supply connections. Possible valve contamination could
occur which will void any warranty. Teflon tape is the recommended sealant.
Product warranties may be found in the “Products” section of our web site at
www.bradleycorp.com.
THIS
SIDE
UP
Packing List
•
•
•
•
Installation
S53-315 Installation
2
6/13/2018 Bradley • 215-1582 Rev. H; ECN 18-02-003
Table of Contents
Faucet Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation
Spout Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mount the Faucet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Connect Valve Control Module . . . . . . . . . . . . . . . . . . . . . . . .5
Faucet Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Connect Drain Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Components for Model S53-315
BATTERY BOX S08-386
4'' TRIM PLATE KIT
159-429 (included)
DRAIN
GROUNDING
WIRE
EARTH
GROUNDING
WIRE
SENSOR
WASHER
VALVE
CONTROL
MODULE
SINK GROUND KIT
(INCL. GROUNDING
WIRES, SPOUT
LOCK WASHER AND
NUT, AND SENSOR
WASHER)
Optional AC Adapters
(in lieu of Battery Box)
SINGLE-UNIT ADAPTER
153-443 6-UNIT ADAPTER BOX
153-444
WIRE ASSEMBLY FOR
6-UNIT ADAPTER BOX
269-1841
(ORDER ONE PER FAUCET)
3'
ref.
5'
ref.
269-1889
GROUNDING
KIT
Aerator Kit S05-177 includes:
• Aerator
• Aerator Key
• Flow control
Spout Kit 269-1918 includes:
• Items marked with *
• (2) M4 x 12mm screws
Valve Control Module Kit 153-447 includes:
• Control Module
• Grounding Kit
• Dirt Filter
• 1/2'' NPS x 1/2'' NPS x 12'' hose included
• (4) Alkaline Batteries included
Flow Control
Installed in Spout Shank
269-1917*
Spout Gasket
269-1915*
Top Spacer
269-1916*
Top Gasket
269-1913
Insulator Spacer
269-1914
M4 x 25mm Screw
269-1911*
3-in-1 Washer
Shank Nuts*
8'' TRIM PLATE KIT
159-428 (optional)
BLACK
SENSOR
WIRE
Installation S53-315
3
Bradley • 215-1582 Rev. H; ECN 18-02-003 6/13/2018
Attach Faucet and Trim Plate to the Deck
1
SINK/COUNTER TOP
TRIM PLATE STUDS
ADRILL TWO 3/8'' (9.5mm)
DIA. HOLES. DRILL 1''
(25mm) DIA. HOLE.
BATTACH TRIM PLATE STUDS
AND SECURE TRIM PLATE TO
SINK USING METAL
WASHERS AND HEX NUTS.
Optional Trim Plate Removal
White Plastic Screw Spacers
Gasket and Faucet Spacers
Trim Plate
Long Trim Plate Screws
ARemove and discard Long
Trim Plate Screws and white
plastic screw spacers.
BAfter removing Trim Plate, re-attach
gaskets and faucet spacer using
shorter M4 x 12MM screws (supplied).
Do not re-install screw spacers.
Short Trim Plate Screws
4
6/13/2018 Bradley • 215-1582 Rev. H; ECN 18-02-003
3Connect the Valve Control Module
APLACE RUBBER
WASHER INTO WHITE
TOP NUT FITTING.
BHAND TIGHTEN VALVE
CONTROL MODULE TO
FAUCET SHANK.
2Attach Activation Hardware to Faucet Shank
3-in-1 Washer
BRASS MOUNTING NUT
SENSOR WIRE CONNECTION WASHER
BRASS MOUNTING NUT
AATTACH GROUNDING
HARDWARE TO SHANK
IN THE ORDER SHOWN.
BATTACH ACTIVATION
HARDWARE TO SHANK
IN THE ORDER SHOWN.
S53-315 Installation
Tab on 3-in-1 Washer must be
positioned 180 degrees opposite
tab on Sensor Connection Washer.
Installation S53-315
5
Bradley • 215-1582 Rev. H; ECN 18-02-003 06/13/2018
5Connect Sink Ground Wire
IMPORTANT
For applications without a Trim Plate,
cut off the Ring Terminal Side and
discard. The remaining portion of wire
can be taped to the Sink Ground Wire
using Electric Tape. For applications
using Trim Plate, refer to Step C.
SINK GROUNDING TAB WASHER
U-TAB CONNECTION
RING TERMINAL SIDE
SINK GROUND WIRE
ACONNECT SINK/DRAIN
GROUND WIRE TO
SINK GROUNDING
TAB WASHER.
CPLACE RING TERMINAL SIDE
ON ONE OF THE THREADED
STUDS AND FASTEN WITH
LOCK WASHER AND NUT.
BCONNECT THIS END OF SINK
GROUND WIRE TO ONE TAB ON
U-TAB CONNECTION.
DATTACH DRAIN
WIRE CLAMP TO
SINK DRAIN
Connect Sensor Wire
BLACK SENSOR WIRE
SENSOR WIRE CONNECTION WASHER
ACONNECT SENSOR WIRE TO
SENSOR WIRE CONNECTION
WASHER.
4
S53-315 Installation
6
6/13/2018 Bradley • 215-1582 Rev. H; ECN 18-02-003
Install and Connect Battery Pack
IMPORTANT
For Installations using Optional AC Power Source,
connect Power Source as shown in Step C.
VALVE CONTROL
MODULE POWER
CONNECTION BATTERY BOX CONNECTOR
(OR AC POWER CONNECTOR)
AREMOVE BATTERY
BOX COVER BY
UNSCREWING (2)
PHILLIPS SCREWS.
CCONNECT BATTERY BOX CONNECTOR (OR AC
POWER CONNECTOR) TO VALVE CONTROL
MODULE POWER CONNECTION.
B
SECURE BATTERY
COMPARTMENT
TO WALL USING
WALL ANCHORS
OR DOUBLE-SIDED
TAPE. INSERT (4)
D-CELL ALKALINE
BATTERIES AND
REPLACE COVER.
7
6Install Earth Ground Assembly
ACONNECT EARTH
GROUNDING CLAMP TO
COLD WATER SUPPLY
BETWEEN SHUT OFF
VALVE AND WALL PLATE.
BCONNECT EARTH
GROUNDING CONNECTOR
TO REMAINING TERMINAL
ON U-TAB CONNECTOR
IMPORTANT
Be sure to attach directly to the
Copper Pipe and not to the Shut
Off Valve.
Installation S53-315
7
Bradley • 215-1582 Rev. H; ECN 18-02-003 6/13/2018
Batteries not inserted correctly Remove cover from battery box and check that the batteries have been inserted to the
correct orientation and are making connection to the contacts. Refer to the battery icons
located on the base of the battery box tray.
Improper or poor connection
to power supply
Check that the connection from the battery box is fully inserted into the female connector
on the valve control box and assure the connector round thumbnut is fully fastened.
Faucet not working
(No flashing red indicator
located inside clear cover
of valve control box)
Low batteries If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries.
Water source valves turned off Open water source valves and check that there is water flow.
Sensor shorted to ground or
unit unable to calibrate
If red indicator is flashing once or multiple times every 4 seconds, there is a problem with
the installation and the sensor is shorted. To verify the control box is working correctly,
carefully disconnect the black sensor wire from the connection washer. With the wire
disconnected, touch the connector at the end of the black wire with your fingers. The
sensor should activate and water should come on. Let go of the connector and the water
should shut off. If the unit works as described above and it malfunctions when you
reconnect the black sensor wire to the spout assembly, then there is an error in the spout
and cover plate installation. If the faucet does not activate as described when touching the
sensor connector, then you have a grounding issue or there is a broken sensor wire (see
troubleshooting below).
Improper ground connection There is improper earth grounding if the faucet activates when you touch any of the steel
braided supply hoses, the brass fitting on the valve box, or the mixing valve. Verify that the
ground clamp has been installed and recheck the connections. Verify the clamp is tightly
fastened directly to the copper pipe for a proper ground connection. Reset the unit
following procedure below*.
Broken or corrupt sensor wire
or defective valve box
electronics.
If the connector has broken off of the black sensor wire or the valve box appears to be
defective please contact Bradley Technical Service. Do not attempt to repair the valve box
or sensor wire.
Faucet not working and
no water flows when
activated
(Red indicator is flashing)
Problem Cause Solution
Troubleshooting Guide
Poor sensor washer and wire
connection
Verify the brass nuts that fasten the connection washer are fully tightened. Reconnect the
sensor wire to the washer. Reset the unit following procedure below*.
Insufficient ground connection Verify that the earth ground clamp has been installed and recheck the connections. Verify
the clamp is tightly fastened directly to the copper pipe for a robust ground connection.
Reset the unit following procedure below*.
Intermittent cycling and/or
water runs on after
activation
Isolation parts are not installed
or not installed correctly.
If the faucet activates when you touch the sink, the unit installation is improper. Check that
isolation components are used and installed correctly. Verify the sink ground connection is
in place and installed properly.
Intermittent cycling and
/or faucet actuation is
overly sensitive
Drain grounding not
connected or assembled.
Check that the drain ground is assembled to the threaded portion of the metal drain ring
(not on the pipe) and is connected to the tab on the valve control box. Reset the unit
following procedure below*.
Water stays on or runs on
after you pull your hand
away
There is sensor short to ground
or unit is not calibrating.
Water stays on
Debris or particulate matter is
trapped in valve
Turn off water source valves. Remove aerator from end of the spout and examine for dirt
and particulates. Inspect and clean input dirt filter. Reinsert filter and turn water source
back on. Actuate faucet several times without the aerator installed to flush any debris from
the valve mechanism until dripping has ceased. Reinstall aerator.
Water is dripping from
spout when not actuated
Dial set to the "open" position
or not turned to the full "auto"
position
Turn the knob on the side of the valve control box fully to the "auto" position (until it hits
the stop) and actuate the faucet by placing your hand near the spout. Water should stop
running and unit will return to the normal idle operation mode once you remove your hand
from the spout.
Dial not turned to the full
"auto" position
Turn the knob on the side of the valve control box fully to the "auto" position (until it hits
the stop) and actuate the faucet several times by placing your hand near the spout. Water
should stop running or dripping and unit will return to the normal idle operation mode once
you remove your hand from the spout.
Reset the unit following procedure below*. If water continues to run, there is an error in the
installation and grounding scheme (see above).
* How to Reset the Unit: Disconnect power source for 10 seconds. The valve will close and the water will stop running. After 10 seconds, reconnect power
supply. Let unit recalibrate for another 20 seconds and verify faucet activation.

Other manuals for Aerada 1200 Series

1

This manual suits for next models

1

Other Bradley Bathroom Fixture manuals

Bradley S19-310TW8 User manual

Bradley

Bradley S19-310TW8 User manual

Bradley S19-120T User manual

Bradley

Bradley S19-120T User manual

Bradley S19-310AC User manual

Bradley

Bradley S19-310AC User manual

Bradley Terreon Classic WF2500 Series User manual

Bradley

Bradley Terreon Classic WF2500 Series User manual

Bradley Express SS Series User manual

Bradley

Bradley Express SS Series User manual

Bradley Express EXD-3/WHTAS User manual

Bradley

Bradley Express EXD-3/WHTAS User manual

Bradley Terrazzo WF2613 User manual

Bradley

Bradley Terrazzo WF2613 User manual

Bradley 500 Series User manual

Bradley

Bradley 500 Series User manual

Bradley S19-304C2 User manual

Bradley

Bradley S19-304C2 User manual

Bradley Express SS Series User manual

Bradley

Bradley Express SS Series User manual

Bradley S19-120 User manual

Bradley

Bradley S19-120 User manual

Bradley S19-310AC User manual

Bradley

Bradley S19-310AC User manual

Bradley LUCENT Series User manual

Bradley

Bradley LUCENT Series User manual

Bradley S19-310SS User manual

Bradley

Bradley S19-310SS User manual

Bradley 500 Series User manual

Bradley

Bradley 500 Series User manual

Bradley WashBar Duo WBD1 User manual

Bradley

Bradley WashBar Duo WBD1 User manual

Bradley S19-315FPBF User manual

Bradley

Bradley S19-315FPBF User manual

Bradley SXWS9561 User manual

Bradley

Bradley SXWS9561 User manual

Bradley WS-3WMT User manual

Bradley

Bradley WS-3WMT User manual

Bradley 400 Series User manual

Bradley

Bradley 400 Series User manual

Bradley TouchTime 1C User manual

Bradley

Bradley TouchTime 1C User manual

Bradley S19-310UU User manual

Bradley

Bradley S19-310UU User manual

Bradley S19-270HD User manual

Bradley

Bradley S19-270HD User manual

Bradley E19-130 User manual

Bradley

Bradley E19-130 User manual

Popular Bathroom Fixture manuals by other brands

Zuchetti Z94281 PRE-INSTALLATION AND INSTALLATION MANUAL

Zuchetti

Zuchetti Z94281 PRE-INSTALLATION AND INSTALLATION MANUAL

HOESCH SenseEase Planning, installation and operating instructions

HOESCH

HOESCH SenseEase Planning, installation and operating instructions

Hansa HANSACLEAR 0455 0300 78 Mounting and operating instructions

Hansa

Hansa HANSACLEAR 0455 0300 78 Mounting and operating instructions

Signature Hardware 428473 Installation

Signature Hardware

Signature Hardware 428473 Installation

Pressalit MATRIX R4870 Mounting instruction

Pressalit

Pressalit MATRIX R4870 Mounting instruction

METHVEN MINIMALIST installation guide

METHVEN

METHVEN MINIMALIST installation guide

Glacier bay HD58303-3701 Use and care guide

Glacier bay

Glacier bay HD58303-3701 Use and care guide

Coastal Paragon NEO ANGLE w/Bi-fold manual

Coastal

Coastal Paragon NEO ANGLE w/Bi-fold manual

Radaway Modo New II Assembly instruction

Radaway

Radaway Modo New II Assembly instruction

Acquabella HERA Maintenance and installation manual

Acquabella

Acquabella HERA Maintenance and installation manual

Franke 7612210067099 Installation and operating instructions

Franke

Franke 7612210067099 Installation and operating instructions

agape PEAR C Assembly instructions

agape

agape PEAR C Assembly instructions

Allen + Roth 1142VA-60-201 manual

Allen + Roth

Allen + Roth 1142VA-60-201 manual

Gessi 54028 manual

Gessi

Gessi 54028 manual

INDA A04660 Mounting instructions

INDA

INDA A04660 Mounting instructions

Luxier SP20-CEC manual

Luxier

Luxier SP20-CEC manual

Ponte Giulio G12JDS06 instructions

Ponte Giulio

Ponte Giulio G12JDS06 instructions

Mora armatur Izzy 705600 Instruction

Mora armatur

Mora armatur Izzy 705600 Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.