GE Mentor EM User manual

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
04/03/2014
User's Manual Mentor EM Portable Equipment
Mentor EM
Portable Equipment
User’s Manual
103M0987 Rev. C

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
ii 04/03/2014
Mentor EM Portable Equipment User's Manual
Documentation no.: A586590/EB.0908
Published by GE Sensing & Inspection Technologies
Date: 04/03/2014 File: MentorEMUser_040314.indd
Printed in 2014
In order to further develop our products, we reserve the right to change data and designs without prior notice. All
rights reserved, particularly rights relating to duplication,
Dissemination and translation excepted. No part of this publication may be reproduced, processed or disseminated
in any form (e.g. through photocopying, microlming, electronic data processing and/or storage or other means)
without the prior written consent of GE Sensing & Inspection Technologies.
Website: http://www.geittechsupport.com
Phone: See listing of Global Tech Support at the end of this manual.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
iii
04/03/2014
User's Manual Mentor EM Portable Equipment
Table of Contents
Chapter 1: Introduction.................................................................................................................................................................................................................................... 1-1
Important Notice ................................................................................................................................................................................................................................... 1-2
Limited Service Warranty .................................................................................................................................................................................................................... 1-5
Safety Information ................................................................................................................................................................................................................................ 1-6
Compliance Information .................................................................................................................................................................................................................... 1-14
Chapter 2: Features........................................................................................................................................................................................................................................... 2-1
Mentor EM Instrument Overview ....................................................................................................................................................................................................... 2-2
Using this Manual.................................................................................................................................................................................................................................. 2-2
Powering On and Connecting to the Instrument ............................................................................................................................................................................ 2-3
Desktop Features .................................................................................................................................................................................................................................. 2-4
Chapter 3: Operation ........................................................................................................................................................................................................................................ 3-1
LaunchingWorkows ........................................................................................................................................................................................................................... 3-2
InstallingNewWorkows .................................................................................................................................................................................................................... 3-2
NavigatingwithinaWorkow............................................................................................................................................................................................................ 3-3
WorkowFeatures ................................................................................................................................................................................................................................ 3-4
EM Setup Menu and Changing Parameter Values .......................................................................................................................................................................... 3-5
Data Display Screens ............................................................................................................................................................................................................................ 3-6
Working with Gates............................................................................................................................................................................................................................... 3-7
Interpreting the LED Indicator Light ................................................................................................................................................................................................. 3-8
Using the Data Review Tool ............................................................................................................................................................................................................... 3-9
Changing the System Settings ......................................................................................................................................................................................................... 3-10
Working with Stored Files .................................................................................................................................................................................................................. 3-11
WiConnections.................................................................................................................................................................................................................................. 3-13
Bluetooth Connections ....................................................................................................................................................................................................................... 3-14
Using the Mentor EM Software.......................................................................................................................................................................................................... 3-15
AppendixA–EMParameterListingwithDenitions............................................................................................................................................................................ AP A-1
AppendixB–Specications....................................................................................................................................................................................................................... AP B-1

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
iv
04/03/2014
Mentor EM Portable Equipment User's Manual

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-1
04/03/2014
User's Manual Mentor EM Portable Equipment
Chapter 1:
Introduction

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-2 04/03/2014
Mentor EM Portable Equipment User's Manual
Important Notice
The following information must be read and understood by any user of GE
Inspection Technologies equipment. Failure to follow these instructions can lead
to errors in measurements or other test results. Decisions based on erroneous
results can, in turn, lead to property damage, personal injury or death. Any use
for medical applications or other purposes is not allowed.
General Warnings
Proper use of test equipment requires three essential elements:
• Selection of the correct test equipment.
• Knowledge of the specic “test application requirements.”
• Operator training.
The operating manual provides instruction in the basic set up and operation of
the testing equipment.
Operator Training
Operators must receive adequate training before using test equipment.
Operators must be trained in general testing procedures and in the set up and
performance required by a particular test.
More specic information about operator training, qualication, certication,
and test specications is available from various technical societies, industry
groups, and government agencies.
Safety Information
ATTENTION! This is an instrument for materials testing. Any use for medical
applications or other purposes is not allowed.
The instrument may only be used in industrial environments.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-3
04/03/2014
User's Manual Mentor EM Portable Equipment
Software
According to the current state of the art, software is never completely free from
errors.
Before using any software-controlled test equipment, please make sure that the
required functions operate perfectly in the intended combination.
Defects/Errors and Exceptional Stresses
If you have reason to believe that a safe operation of your instrument is no
longer possible, you have to disconnect the instrument from its AC Power
Adapter/Battery Charger, shut it down, and secure it against unintentional
reconnection.
A safe operation is no longer possible if:
• The instrument shows visible damages.
• The instrument no longer operates perfectly.
• Being subjected to heavy stresses during transportation
• After prolonged storage under adverse conditions like exceptional
temperatures and/or especially high air humidity, or corrosive environmental
conditions.
Service
Every effort has been made to provide you with a reliable product. However,
should service become necessary, GE Inspection Technologies has established
a number of Factory Trained Service Centers. For the location of the nearest
facility, refer to the end of this user manual.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-4 04/03/2014
Mentor EM Portable Equipment User's Manual
Batteries
Only batteries (Lithium-ion) recommended and supplied by GE Inspection
Technologies may be used for instrument operation.
NOTE:
Internal batteries may only be replaced by a factory trained service center.
Opening the instrument case in an attempt to access the batteries will void the
instrument’s warranty. An externally connected battery pack is available from
suppliers as described in this manual.
NOTE:
When the instrument reaches the end of its life, the Lithium-ion battery must
be removed. Then properly dispose of the instrument and of the Lithium-ion
battery.
Power plug
Class 1: For AC line powered equipment the power plug may only be inserted
into a grounding-type receptacle. Any disconnection or interruption of the
protective conductor may make the instrument unsafe. When connecting
equipment with other devices, the protective conductors shall be made
equipotential.
Class 2: Use only the power cord and AC Power Adapter/Battery Charger
supplied by GE Inspection Technologies for this instrument. Serious harm to the
instrument is highly likely if the incorrect power supply is used.
ChargerSpecications
AC input to charger specication: 100–240 VAC, 47–63 Hz
DC charge input specication: 12 VDC ± 5%, 72 W

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-5
04/03/2014
User's Manual Mentor EM Portable Equipment
Limited Service Warranty
If, through our negligence, GE Inspection Technologies directly caused damage
to your equipment while the equipment is in the sole custody and control of
GE Inspection Technologies, we shall choose at our opinion either to repair
the damage or replace the damaged portion of the equipment at our own
expense, or to indemnify and hold you harmless for such physical damage to
the Equipment. The equipment shall be free of any claim of ownership by third
parties and when new, be free from defects in material and workmanship and
perform in accordance with the Product’s specications under normal use and
service.
EXCEPT FOR THE WARRANTY SET IN THIS PARAGRAPH, GE INSPECTION
TECHNOLOGIES EXPRESSLY DISCLAIMS ALL WARRANTIES AND REPRESENTAION
OF ANY KIND WITH RESPECT TO OUR SERVICES OR THE INFORMATION
CONTAINED IN ANY REPORTS THAT WE ISSUE TO YOU, WHETHER EXPRESSED OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, TITLE AND WARRANTIES
ARISING FROM COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE
USAGE.
This limited warranty shall not apply to any problems arising from (i) failure to
follow the product instructions or failure to perform preventive maintenance,
(ii) service, repair or modication by someone other than GE Inspection
Technologies or one of our authorized service representatives; or (iii) external
causes, such as accident, abuse, misuse, or problems with electrical power.
The use of unauthorized spare parts shall render the manufacturer’s warranty
null and void.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-6
04/03/2014
Mentor EM Portable Equipment User's Manual
Safety Information
Follow the safety instructions and exercise caution at all times to reduce the risk
of accidents, personal injury, and material damage.
NOTE:
This message indicates additional information.
DANGER!
Immediate danger: situation will cause death or serious injury if not averted.
WARNING!
This term indicates danger and the possibility of personal injury.
CAUTION
This term indicates that damage could occur to equipment.
WARNING!
Danger resulting from misuse!

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-7
04/03/2014
User's Manual Mentor EM Portable Equipment
WARNING!
Equipment to be operated by authorized personnel only.
Wear Personal Protective Equipment when there are risks of injury!
ELECTRICITY!
Potential death or serious injury may result from contact with electrically
charged components. An electric charge can build up in electronic components
and remain even after switching off and disconnecting the equipment from the
power supply.
WARNING!
Instruments containing wireless devices are designed for use in specic
countries. Instrument user is responsible for ensuring that the instrument’s
wireless devices are only used in countries for which they are intended.
WARNING!
Operation of some wireless devices on airlines is prohibited because their
signals could interfere with critical aircraft instruments.
WARNING!
The instrument contains a Lithium Ion battery and magnesium in its case.
Should the instrument be involved in a re, use an extinguisher approved for use
on electrical and ammable metal res. Water must not be used.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-8
04/03/2014
Mentor EM Portable Equipment User's Manual
CAUTION
There are no serviceable parts inside the instrument. Do not open the
instrument housing.
WARNING!
Surfaces on the rear of the instrument can become hot under normal operating
conditions.
WARNING!
Support stand can cause injury if allowed to close on ngers.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-9
04/03/2014
User's Manual Mentor EM Portable Equipment
Compliance Information
Instrument conforms to the following regulations:
EMC Directive 2004/108/EC
FCC Part 15, Subpart B, Class A
R&TTE Directive 1999/5/EC
Instrument carries the following agency markings:
Federal Communications Commission
European Commission
Wireless Module Approvals:
IEEE 802.11b/g/n
FCC Part 15, FCC ID: XF6-RS9110N1102
IC ID: 8407A-91101102
Bluetooth (BT) 2.1 + EDR
FCC Part 15, FCC ID: QOQWT32AE
IC ID: 5123A-BGTWT32AE

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-10
04/03/2014
Mentor EM Portable Equipment User's Manual
NoticationsforWirelessModules:
• The modules are Class 1 and are exempt under sub “class 22, Wideband
Data Transmission Systems 2400 -2483.5 MHz”.
• The wireless modules utilize the 2.4 GHz band.
• The modules are designed to be embedded into general electric devices, and
are not designed for aircraft instruments, atom control, articial life support
and any other devices requiring extremely high reliability and quality.
• As the modules communicate via radio waves, it is strongly recommended
that conguration be performed regarding security, to prevent information
leakage to a third person.
• The modules are wireless modules for embedded use. Please understand the
functions and features of the modules, and test the nal product into which
the modules have been embedded. Also, as an EMC measurement of the
modules has not been performed, an EMC test and application must be per-
formed with the nal product into which the modules have been embedded.
• The modules may effect or be affected by any surrounding devices utilizing
the same bandwidth. Please investigate the environment in which the modu-
les will be operated before installing it.
• Disassembling or modifying the modules may lead to penalties based on
radio wave law.
• The modules are an embedded module that has its connectors and parts
exposed. Be careful to avoid electrostatic discharge, water contamination,
and powder or dust contamination.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-11
04/03/2014
User's Manual Mentor EM Portable Equipment
Canadian Notice for Wireless:
This equipment does not exceed the Class A limits for radio noise emissions as
described in the Radio Interference Regulations of the Canadian Department of
Communications.
Le present appareil numerique n’emet pas de bruits radioelectriques depassant
les limites applicables aux appareils
numeriques de la classe A prescrites dans le Reglement sur le brouillage radio-
electrique edicte par le ministere des
Communications du Canada.
FCC Notice for Wireless:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equip-
ment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
IMPORTANT: Under FCC rules, modications not expressly approved by the
manufacturer could void the user's authority to operate the equipment.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-12
04/03/2014
Mentor EM Portable Equipment User's Manual
Mexico Wireless Information:
La operación de este equipo está sujeta a las siguientes dos condiciones:
1) es posible que este equipo o dispositivo no cause interferencia perjudicial y
2) este equipo debe aceptar cualquier interferencia, incluyendo la que pueda causar su propia operación
no deseada.
Brazil Wireless Information:
“Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos
requisitos técnicos aplicados”
Para maiores informações, consulte o site da ANATEL www.anatel.gov.br
Taiwan Wireless NCC Information
低功率電波輻性電機管理辦法
第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號或使
用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。
第十四條低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發
現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。
前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍受合法通信
或工業、科學及醫療用電波輻射性電機設備之干擾。

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-13
04/03/2014
User's Manual Mentor EM Portable Equipment
Thailand Wireless NTC Information:
This telecommunication equipment conforms to NTC technical requirement
South Korea Wireless Information:

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-14
04/03/2014
Mentor EM Portable Equipment User's Manual
Disposal of packaging materials
Dispose of packaging material in accordance with legal requirements and local
regulations.
Environmental Compliance
GE Inspection Technologies is an active participant in Europe’s Waste Electrical
and Electronic Equipment (WEEE) take-back initiative, directive 2002/96/EC.
The equipment that you bought has required the extraction and
use of natural resources for its production. It may contain
hazardous substances that could impact health and the
environment. In order to avoid the dissemination of those
substances in our environment and to diminish the pressure on
the natural resources, we encourage you to use the appropriate
take-back systems. Those systems will reuse or recycle most of the materials of
your end life equipment in a sound way.
The crossed-out wheeled bin symbol invites you to use those systems. If you
need more information on the collection, reuse and recycling systems, please
contact your local or regional waste administration.
Visit www.ge.com/inspectiontechnologies for take-back instructions and more
information about this initiative.
Battery Disposal
This product contains a battery that cannot be disposed of as
unsorted municipal waste in the European Union. See the product
documentation for specic battery information. The battery is with
this symbol, which may include lettering to indicate cadmium (Cd),
lead (Pb), or mercury (Hg). For proper recycling return the battery
to your supplier or to a designated collection marked with this symbol, which may
include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling return the battery to our supplier or to a designated collection point.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-15
04/03/2014
User's Manual Mentor EM Portable Equipment
Maintenance
Inspecting and Cleaning the System
Inspect and clean the Mentor EM system before and after each use with the a
soft cloth and a 70% alcohol-to-water solution. If using the system in a dirty
environment, clean the components more frequently, as needed.
If damage is found, contact GE Inspection Technologies for return instructions and
an RMA (return material authorization) number.
Early detection of minor conditions can prevent costly repair.

Copyright by GE Sensing & Inspection Technologies 50 Industrial Park Road Lewistown, PA 17044
1-16
04/03/2014
Mentor EM Portable Equipment User's Manual
Table of contents
Other GE Test Equipment manuals

GE
GE Druck ADTS 542F Setup guide

GE
GE Druck DPI611 Operating and maintenance instructions

GE
GE Druck DPI 880 User manual

GE
GE ADTS542F User manual

GE
GE Druck DPI 841 User manual

GE
GE Druck DPI 610 User manual

GE
GE Druck ADTS 405 R Mk2 User manual

GE
GE Druck DPI612 User manual

GE
GE MicroVersaTrip TVTS1 User manual

GE
GE Druck DPI 610 User manual