Use
The KEMPER FROSTI®-PLUS is used
as a frost-proof outdoor tap.
Do not use the product for other
purposes than described above.
Any other uses constitute misuse.
Warnings
Be sure to read and follow the warn-
ings in the manual. Failing to do so
can lead to personal injury or material
damage!
Important warnings:
Warning! Highlights risks
that may result in injury,
material damage or contami-
nation of drinking water.
Note! Highlights risks that
may result in damage to the
plant or dysfunction.
Warning! The FROSTI must
be installed in accordance to
Water Regulations, schedule
2, paragraph 15. The level of
protection must be appropriate
to the fluid category.
Precautions
for preliminary installation
Drinking water installation
In order to prevent stagnation and
bacterial contamination in the supply,
it is recommended to loop the tap in
the drinking water system.
*For technical and hygienic reasons,
it is necessary to install the last
min. 100 mm and max. 10 x DN as
a functional individual supply line.
** The tap must be installed at least
250 mm above the maximum fluid
level.
Installation
Read the manual and follow the
instructions before installation!
Installation and maintenance must be
carried out by qualified plumbers.
Keep the manual for future reference!
The place of installation may not be
at risk of flooding.
Perform a leak test after installation
and before commissioning!
Priority must be given to the national
standards and provisions on sanitary
installations and accident prevention.
All dimension specifications are given
in mm.
Warranty
No warranty in case of:
- Non-compliance with the manual.
- Damage due to incorrect installation.
- Unauthorised modification of the product.
BS EN 1717
max.
min. 250**
min. 100**
DN