Open the
menu Select the
menu name Select the set item Change the
set content
Close the menu
1st time: The menu returns to the set item.
2nd time: The menu returns to the menu name.
The selection and the change
of set content can be performed
by rotating the knob.
①Change the image speed.
The image speed becomes slow in order of [Speed1]→[Speed2]→・・・→
[Speed9].When [stop] is selected, the image stops.
②It rejects the interference with other echo sounder.
When [Strong] is selected, the effect of rejection is strong.
③It rejects the weak noise appeared on the display.
The greater the number is, the stronger the rejection becomes.
④It rejects the speck-like noise appeared on the entire image.
The greater the number is, the stronger the rejection becomes.
⑤Set the TVG.
The deep depth gain increase in order of [Weak]→[Medium]→[Strong].
⑥It sets the TX power.
⑦The reduction in sensitivity due to signal attenuation in Gain(TD)
use and so on can be corrected.
You can make numerical value bi
er at the time of lack of sensitivit
.
①It sets the quantity of movement of shift.
②It selects the kind of the zoom type.
③It sets the range of image
selected in ②.
④It sets the zoom starting position of
image set in ②.
⑤It selects the disp width.
⑥It presets the range.
Zoom
Zoom ran
e
Zoom start
djust
D.range
Display1
Display2
larm1
larm2
NAV
Image
System
Shift step 1m
Zoom type BTM.
Zoom range 10.0m
Zoom start 0m
Disp width Center
Range preset
Return
①
②
③
④
⑤
⑥
●Function of display range set menu
djust
D.range
Display1
Display2
larm1
larm2
NAV
Image
System
Image speed Speed5
IR Strong
Color rejection 0%
Noise rejection 0
TVG Medium
TX power
uto
Gain(TD)
①
②
③
④
⑤
⑥
●Function of Adjust Set Menu
Close the menu
●How to operate the menu
Return ⑦
Next
Next
●Preset of Range
Registration of the range can be easily changed with following operation. Preset the set value suitable for you purpose.
Press
Press
Rotate
Press Press Press
Rotate
Press
*Select by performing
either operation.
*Select by performing
either operation.
Press
50.0
100
160
300
500
5.0
10.0
20.0
uto shift
0093132704-03
uto range Range 5.0
Range