manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxby Lighting
  6. •
  7. Lighting Equipment
  8. •
  9. Saxby Lighting Louvre Photocell User manual

Saxby Lighting Louvre Photocell User manual

This manual suits for next models

1

Other Saxby Lighting Lighting Equipment manuals

Saxby Lighting Icarus Twin Wall EL-40054 Manual

Saxby Lighting

Saxby Lighting Icarus Twin Wall EL-40054 Manual

Saxby Lighting Odyssey 78667 User manual

Saxby Lighting

Saxby Lighting Odyssey 78667 User manual

Saxby Lighting 51994 Manual

Saxby Lighting

Saxby Lighting 51994 Manual

Saxby Lighting Lucca Wall 67176 Manual

Saxby Lighting

Saxby Lighting Lucca Wall 67176 Manual

Saxby Lighting 10430 Manual

Saxby Lighting

Saxby Lighting 10430 Manual

Saxby Lighting Reeve Connect Batten Series Manual

Saxby Lighting

Saxby Lighting Reeve Connect Batten Series Manual

Saxby Lighting Varone 55702 Manual

Saxby Lighting

Saxby Lighting Varone 55702 Manual

Saxby Lighting Severus CCT User manual

Saxby Lighting

Saxby Lighting Severus CCT User manual

Saxby Lighting Regen Manual

Saxby Lighting

Saxby Lighting Regen Manual

Saxby Lighting 76768 Manual

Saxby Lighting

Saxby Lighting 76768 Manual

Saxby Lighting 97818 User manual

Saxby Lighting

Saxby Lighting 97818 User manual

Saxby Lighting Lucca Mini User manual

Saxby Lighting

Saxby Lighting Lucca Mini User manual

Saxby Lighting Odyssey Bollards ST501228 User manual

Saxby Lighting

Saxby Lighting Odyssey Bollards ST501228 User manual

Saxby Lighting 13929 User manual

Saxby Lighting

Saxby Lighting 13929 User manual

Saxby Lighting 67360 User manual

Saxby Lighting

Saxby Lighting 67360 User manual

Saxby Lighting Hero CCT User manual

Saxby Lighting

Saxby Lighting Hero CCT User manual

Saxby Lighting ALBA SOLAR POST PIR User manual

Saxby Lighting

Saxby Lighting ALBA SOLAR POST PIR User manual

Saxby Lighting E27 LED GLS Manual

Saxby Lighting

Saxby Lighting E27 LED GLS Manual

Saxby Lighting Sight Plus 72638 Manual

Saxby Lighting

Saxby Lighting Sight Plus 72638 Manual

Saxby Lighting Tango User manual

Saxby Lighting

Saxby Lighting Tango User manual

Saxby Lighting Sight Twin Spot Manual

Saxby Lighting

Saxby Lighting Sight Twin Spot Manual

Saxby Lighting 1818PIR Manual

Saxby Lighting

Saxby Lighting 1818PIR Manual

Saxby Lighting Aqualine Kit Manual

Saxby Lighting

Saxby Lighting Aqualine Kit Manual

Saxby Lighting 13801 User manual

Saxby Lighting

Saxby Lighting 13801 User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.saxbylighting.com
Instruction manual
97853
Louvre Photocell
Technical data
220-240V~, 50Hz
Supply
Voltage:
Bulb
Type:
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
This product is rated at IP44
IP
44
1 x Max. 60W E27 GLS (required)
This is a Class 1 product and must be earthed.
Allow 10 minutes to cool before replacing, adjusting or cleaning.
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Care and Safety
Replace Cracked Shade
The bulb source is protected by the shade. The shade must be replaced immediately
should it become cracked or damaged. This fitting must not be used without the shade
in place.
V1 09/07/2021
EU Manufacturer: 1 Gnarrenburg, 27442
UK Manufacturer: BH17 7BY
Conformity with all relevant UKCA Directive requirements.
Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Installation
This is a Class 1 product and must be earthed.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
This product is not suitable for location in or near a marine environment. The product will not withstand long periods of
immersion in water.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
This light fitting should be connected to a circuit with a 30mA RCD fitted. If replacing an existing fitting, make a careful note
of the connections.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
Please read these instructions carefully before commencing any work. This unit must be fitted by a competent and qualified
electrician. Check the pack and make sure you have all the parts listed. Install in accordance with the IEE Wiring regulations
and current Building Regulations.
Cables must be protected using suitable conduit or plastic trunking.
The mains supply cable must have a minimum cross sectional area of 1.0mm2.
We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber sheathed cable.
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction boxes
(not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
The product must be mounted onto a concrete base or paving slab. It should not be directly installed in the soil.
This product is designed for domestic and light industrial use, It should not be used to support other
objects or used as a replacement for concrete or metal pillars.
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the junction box
and the light fitting.
Layout
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
1) Position the supplied right angle Jbolts as shown in the below diagram.
Use the base of the unit for alignment.
2) Position the conduit or plastic trunking so that the cable comes up that the
centre point of the bollard. Ensure that the cables do not snag.
3) Double check that the fixings line up with the holes in the base of
the fitting before concreting into position, and allow to set.
• Refet to below diagram to complete the base installation
• Pull the terminal block from inside of the tube, Connected the incoming mains
as per the wiring diagram. then push the terminal block up into of the tube.
• Fit the bulb, unscrew the shade and insert the bulb.
• Fit the fitting to the base by the washers and dome nuts, tighten dome nuts to secure.
Fitting
Supplied Fixings
Conduit
Concrete Base
• Screw the shade back in place.
• Replace fuse or circuit breaker and
switch on. Your light is now ready for use.
Having correctly identified the wiring from your existing light fitting, pull the mains wire through the conduit and connect to the
terminal block in the following way:
Wiring
You have to correctly identified the wires.
The connections are tight.
No loose strands have been left out of
the connection block.
Check that...
SUPPLY
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
LIGHTFITTING
BLUE (N)
BROWN (L)
GREEN/YELLOW