Warning
Please read these instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
This system operates at Safety Extra Low Voltage (12V), via a transformer. Never connect the light fittings directly to the
mains without using a transformer. Ensure that the supplied transformer is used.
The mains plug must be situated indoors (e.g. house, garage, shed) in order to protect it from the elements.
Do not exceed the transformer load. Transformers may require a minimum load to operate.
Always disconnect the transformer from the mains when installing or maintaining this system.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
This product is rated at IP67. They are suitable for installation in very wet areas, but must not be permanently submerged.
The transformer must not be installed directly in the soil, but placed in a protective box.
Rated maximum surface temperature is 100 ºC.
The resistant to static loads is 5KN for 1 mintue. Do not let plants grow close to the lamp. This product is not suitable for
drive-over, carriageways, parkings, etc.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instruction for future reference.
Layout
Plan the desired layout of these fitting carefully, ensuring the cables will reach distances between the out door transformer, the
outdoor junction box and each light fitting..
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Avoid locating any cables in positions that would cause a trip hazard. Position cables and junction box away from areas where
they may be at risk from being cut, trapped or damaged.
The power supply is Double Insulated and does not require connection to an Earth circuit.
The LED units are Safety Extra Low Voltage and must not be earthed.
The mains plug must be situated indoors. The kit can be wired into an IP67 external terminal block. This must be carried out by
a competent and qualified electrician.
The transformer and junction box are rated at IP67 and can be positioned outdoors.
These fittings should not be installed/mounted in concrete.
This LED lighting kit is designed for indoor and outdoor installation for use in patios, in walls, on decking, step edges, in
pathways and in other areas of the garden.
1. Position the plug next to the indoor mains outlet socket that the system will connect to. Do not plug-in at this stage.
2. After deciding the layout of the light fittings, and the positon of the junction box, ensure the cables are long enough to
connect to the desired positions.
3. Drill the mounting holes for the light units taking care not to damage any pipes or mains cables beneath the mounting
surface. drill a 22mm clearance hole, Minimum hole depth is 35mm. It is always recommended to cut the hole slightly
smaller than the size specified, and then file the hole until the recessed unit fits snugly.
If not using the supplied plug then the product must be wired to an IP67 (or higher rated) terminal block
(recommended terminal block ref. 90131/90132).
Having correctly identified the wiring from your existing light fitting, connect to the approved outdoor rated external terminal
block in the following way:
Wiring
You have correctly identified the wires.
The connections are tight.
No loose strands have been left out of the
connection block.
Check that...
NEUTRAL
SWITCHED LIVE
BLUE (N)
BROWN (L)
SUPPLY LIGHT FITTING
30mm diameter LED
22mm diameter
mounting hole
(minimum 35mm depth)
4. Feed the plug and cable of each light unit through the mounting holes and push unit into the hole to secure.
5. Connect each LED light to the junction box ensuring each plug is fully screwed into the junction box sockets.
6. Ensure that all the LED heads are connected to IP67 junction box.
7. Connect the transformer cable into the end socket on the junction box.
8. Connect the transformer cable into the end socket on the junction box.
9. Plug the transformer into the mains socket and switch on to test.
The Kit contains:
1 x 12V IP67 inline transformer with 10 metres of cable
1 x Outdoor rated 10-way junction box
10 x LED light fittings each with 3 metres of cable attached & 3 pin plug