Seca 763 User manual

16
English
1. Congratulations!
Your purchase of this integrated measure-
ment station seca 763 means you have a
high-precision and sturdy electronic body
height and body weight measuring instru-
ment. seca has been putting its experi-
ence at the service of health for over 150
years now, and as market leader in many
countries of the world, is always setting
new standards with its innovative develop-
ments for weighing and measuring.
The integrated seca 763 measurment
station is primarily used in accordance
with national regulations in hospitals, doc-
tor's practices and health care centers.
The integration of electronic scales and
electronic height measurement in one
deivce means the seca 763 is particularly
suitable where weighing and measuring
must be carried out where little space is
available. The data measured can be con-
verted at the push of a button into a Body
Mass Index. The telescoping design used
for the height measurement unit as well as
the retractable head slide allows the de-
vice to be easily moved on the built-in cas-
tors.
The sturdy design and intelligent power
management system ensure a long period
of maintenance-free service so that the
device can be used for years to come. Op-
eration is easy with two large displays al-
lowing weight and height to be read out
simultaneously.
2. Safety
Before using the device, please take some time to read the following safety instructions.
•Follow the safety instructions in the in-
struction manual.
•Keep the operating manual and the
declaration of conformity contained
therein in a safe place.
•Never drop the deivce or expose it to
strong shocks.
•Have repairs carried out exclusively by
authorised persons.
•After moving the device, place it care-
fully back in the position for use.
•After using the height measurement
unit fold the head slide down. This
avoids the hazard of injury.
•Be sure to use only the seca AC adap-
tor supplied. Before plugging the AC
adaptor into a socket, check that the
mains voltage indicated on the AC
adaptor matches local mains voltage.
•When using the device with an AC
adaptor, be sure that the power supply
cable does not pose any danger of trip-
ping or entanglement.
•Be sure to have the device maintained
regularly (see "Maintenance").
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 17
3. Before you start…
Unpacking
Remove the packaging and place the
based on a solid,
even surface.
The equipment supplied includes:
• Base of scales
•Column with integrated height meas-
urement and display head
• Protective cover for column
• SW 3 Allen spanner
• SW 5 Allen spanner
• 2 screws
• seca AC adaptor
•Operating instructions with a declara-
tion of conformity
Mounting the column
–Place the protective cover onto the col-
umn.
–Place the column in to the notch so that
the folding head slide is pointing down
toward the platform.
–Screw the column from beneath onto
the weighing platform.
–If needed, carefully place the scales on
the side to tighten the screws.
–As shown in the illustration, connect the
power supply cable on the bottom of
the weighing platform.
–Insert the plug of the display cable in
the jack on the bottom of the weighing
platform.
– Fasten the cable in the cable guide.
–Now put the device back in an upright
position.
–Slide the column cover all the way
down until it locks into place on the
weighing platform.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

18
Power supply
The power supply must come from the
supplied AC adaptor.
The connector for the AC adaptor is locat-
ed under the rod.
Please only use the power supply unit
supplied with the product or power supply
units from the seca accessories range.
Before plugging into the socket, check
whether the mains voltage details on the
power supply unit match those of the local
voltage supply.
Please use only the mains unit supplied or mains units from the seca range of
accessories. Before plugging the unit into the socket, check whether the mains
voltage marked on the mains unit matches local mains voltage.
4. Setting up and aligning the scales
– Place the scales on a level surface.
–Align the scales by removing the foot
screws. The scales must stand secure-
ly on the floor on all four feet.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 19
5. Operation
Controls and displays
The controls and display are in the display part.
Switching the device on and off
Press button briefly →switch between kg and lbs
hold down →switch between kg and sts
In the function menu →Raise the value
Press button briefly →Active/deactivate hold function
hold down →Set the display to zero, activate/deactivate TARE
In the function menu →Lower the value
Activate BMI function, confirm
Toggling the unit of height measurement between cm and inch
Setting the height measurement to zero for relative measurements
Pushing button to mark the valid height measurement value
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

20
Correct weighing
–Press the Start key with no load on the
scale.
se(a, 8.8.8.8.8. and 0.0 appear consec-
utively in the display. The scale is then
automatically set to zero and ready to
use.
–If necessary, change over the weight
display (see "Switching the weight dis-
play").
–Stand on the scales and remain
motionless.
–Read the weighing result off the digital
display.
–If a weight of more than 250 kg or
550 lbs is placed on the scales, then
St0P appears in the display.
–To switch off the scales, press the Start
button again.
Switching the weight display
The weight display can be switched between kilogrammes (kg) and pounds (lbs) or bet-
ween kilogrammes (kg) and stones (sts).
–Switch on the scale using the green
START key. Weight is initially displayed
in the last setting selected.
–To switch the weight display between
kilogrammes and pounds, press the
kg/lbs/sts key.
– The kg or lbs display lights up.
– To switch weight display between
pounds and stones, hold down the
kg/lbs/sts key for approx. 2 seconds.
– The lbs or sts display lights up.
Switching off the device
– To switch off the scales, press the Start button again.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 21
Taring weight display (TARE)
The TARE function is useful if an additional weight should not be considered while weigh-
ing.
Proceed as follows:
–Press the Start key with no load on the
scale.
–First, place the additional weight onto
the scales and activate the TARE func-
tion by pressing the HOLD/TARE but-
ton.
The display is reset to zero. 0.0 appears
in the display. The note “NET” appears.
–Now place the patient onto the scales
with the previously weighed additional
weight.
The scales show the weight of the pa-
tient without the additional weight. You
can now perform as many weighing
operations as you like.
–Deactivate the TARE function by press-
ing the button again; this puts the
scales back into the normal weighing
mode, the tare value (the additional
weight value) is deleted.
–The tare value is likewise erased when
the scales are switched off.
Store weight value (HOLD)
You can also continue displaying the weight determined once the load has been removed.
This makes it possible to look after a patient first, before having to note the weight:
–Press the HOLD/TARE button while
the scales have a weight on it.
–“HOLD” appears in the digital display.
The weight remains stored in the dis-
play until the Hold function is automati-
cally switched off.
–The triangle with the exclamation mark
indicates that this frozen display is an
additional facility which is not subject to
calibration.
–The HOLD function can be switched off
by pressing the HOLD/TARE key
again.0.0 appears in the display if the
scales have no load, otherwise the cur-
rent weight is shown. The “HOLD” dis-
play vanishes.
Note: The HOLD and TARE functions can also be used simultaneously.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

22
Height measurements
–Press the START button on the display
housing to switch on the device.
First appears in the height display.
The unit selected before switching off the
device is active and is marked by an ar-
row.
–If required, switch the unit of height
measurement (see “Toggling unit of
height measurement”).
–Raise the head slide up and push the
head slide up far enough for the person
whose height is being measured to
easily stand under it.
–Ask the person being measured to
place his back against the height rod.
Make sure the person's posture is up-
right and head is straight.
–Now push the head slide down until it
rests on the person's head.
– Read off the height on the display.
Toggling unit of height measurement
The display can toggle between "cm" and "ins" (inches).
–Switch the device on. The height read-
out is displayed in the most recent unit
selected.
–To switch the unit displayed press the
cm/ins button.
–An arrow lights up next to the cm or
ins display.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 23
Relative measurements
The height rod can be set to zero at any position. This function allows extremities to be
measured.
–Press the ZERO button in order to set
the height rod to zero at its current po-
sition.
ZERO SET is highlighted in the display.
All lengths are now measured starting
from this zero set point. Any measure-
ment below this zero point will cause re-
sults to be displayed with a minus sign.
–Press the ZERO button again if you
want to start measuring from absolute
zero again.
Body Mass Index (BMI)
The Body Mass Index compares body size with body weight while also allowing more pre-
cise information to be determined for ideal body weight according to Broca. A tolerance
range is given which is considered ideal for health.
By using the integrated measurement station seca 763 you can have the Body Mass In-
dex calculated directly from the size measured and the measured weight. Please follow
these steps.
–Press the Start key with no load on the
scale.
se(a, 8.8.8.8.8. and 0.0 appear consec-
utively in the display. The scale is then
automatically set to zero and ready to
use.
– Now measure height as described.
After you have determined that the pa-
tient is standing up straight and the
head slide is correctly positioned, then
please push the DATA VALID button.
This marks the height measurement as
a valid value for the Body Mass Index
calculation.
– Push the head slide back up.
–Now read the weight value in the
weight display.
–Press the FUNC key. The measured
height which is marked as valid now
appears in the display. Push the kg/
lbs/sts buttons (raise the value) or
HOLD/TARE (lower the value) if you
want to correct the height, for example
to compensate for shoe heel height.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

24
–Push the FUNC button again The BMI
function is now activated.
–Now the patient should try to stand as
still as possible.
–Read the BMI on the LED and compare
it with the categories under "Evaluating
Body Mass Index“.
–To return to normal weighing mode,
press the FUNC key.
–To switch off the scales, press the Start
button again.
Note:
The Body Mass Index is correctly calculated even when you have not selected
metric display units.
Evaluating Body Mass Index for adults:
Compare the value determined with the categories quoted below which correspond to
those used by WHO, 2000.
• BMI below 18.5:
Warning, this patient weighs too little. There could be a tendency to anorexia. An in-
crease in weight is recommended to improve well-being and performance. If in doubt,
consult a specialist.
• BMI between 18.5 and 24.9:
The patient is of a normal weight. He can stay as he his.
• BMI between 25 and 30 (pre-obese):
The patient is slightly to moderately overweight. The patient should lose weight if a pre-
vious illness exists (such as diabetes, high blood pressure, gout, lipid disorders).
• BMI over 30:
Weight reduction is essential. Metabolism, cardiovascular system and bones are all un-
der strain. A consistent diet, plenty of exercise and behavioural training are all recom-
mended. If in doubt, consult a specialist.
6. Care and cleaning
When needed, clean the device with a household cleaning agent or other common disin-
fectant. Follow the manufacturer’s instructions.
Under no circumstances use abrasive or acid cleaners, white spirit, benzene or the like
for cleaning. Such substances can damage the high-quality surfaces.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 25
7. What to do if …
… no weight or height readout appears?
– Is the device switched on?
–Is the plug between the power supply connector in the rod and base properly connect-
ed?
– Is the plug contact of the AC adaptor properly connected on the device rod?
– Is the plug contact for connecting the display and the base properly connected?
… 0.0 does not appear before weighing?
–Press the start button again – there must not be any load on the scales – and only its
feet should be in contact with the floor.
… one segment is illuminated constantly or not at all?
– The relevant segment has a fault. Inform Servicing.
… St0P appears in the weight display?
– Maximum load has been exceeded.
… the weight display is blinking?
–If you have just activated the Hold or Tare function, please wait until the scales have
detected a steady weight value. The display will then stop flashing.
–If there has been no activation of a function beforehand, remove the load from the
scales and wait until 0.0 is displayed, then weigh again.
… the display appears?
–The ambient temperature of the device is too high or too low. Place the device where
the ambient temperature is between +10 ˚C and +40 ˚C. Wait about 15 minutes until
the device has adjusted to the ambient temperature and weigh again.
… the display and a number appear?
–Use the Start button to switch off the device and start again. After this the device will
function normally.
–If this is not the case, disconnect the power supply by briefly unplugging the AC adap-
tor. If this measure is equally unsuccessful, inform the Service department.
… appears in the height display?
–Slide the head slide up or down quite a ways. This will make the head slide pass a mark
which can be evaluated and the system can now calculate the position correctly again.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

26
… the head stop slides down and does not stay in the required position?
–Place the scale carefully on its side so
that the base of the scale is accessible.
Insert the Allen key supplied in the rec-
tangular hole on the end of the measu-
ring rod as shown in the illustration and
tighten up the screw for the measuring
rod guide clockwise.
The measuring rod with the head stop
should remain freely mobile, but not be
able to slide down on its own.
Then stand the scale upright again.
8. Servicing
Your seca scale leaves the factory with an accuracy greater than ± 0,15 %. To ensure that
this accuracy is maintained, the product must be carefully set up and regularly maintained.
Depending on the frequency of use, we recommend servicing every 3 to 5 years. Please
ensure that a qualified service agent is used. If in doubt, contact seca Customer Service for
further information.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

Model 763 27
9. Technical data
10. Spare parts
Device dimensions
Width: 360 mm / 14.2 ins
Height: 1320 +10 mm / 52 +0.4 ins
Depth: 686 mm / 27 ins
Weight approx 20.5 kg
Temperature range +10 to +40 °C
Insulated equipment, Protection Class II:
medical electrical equipment type B
Colour white/black
Maximum load 250 kg / 550 lbs / 39 sts
Graduations 50 g / 0.1 lbs
Precision better than ±0.15% / ±100g
Height measurement
Precision Tolerance of ±2 mm
Reproducibility ±1 mm
Measurement range 110 - 200 cm / 43 - 79 ins
Resolution 1 mm / 0.05 ins
RS232 adapter kit with print port Order no. 460-00-00-004
Model-specific power unit
Designation:
Plug-type AC adaptor 230 V~/50 Hz/12 V=/130 mA
Order no. 68-32-10-252
Designation:
Switchmode power adapter,
100-240V~ / 50-60Hz / 12V= / 0.5A Order no. 68-32-10-265
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer

28
11. Disposal
Disposing of the device
Do not dispose of the device in
domestic waste. The device must
be disposed of properly as elec-
tronic waste.
Follow the national regulations which ap-
ply in your case. For further information,
contact our service department at:
12. Warranty
A two-year warranty from date of delivery
applies to defects attributable to poor ma-
terials or workmanship. All moveable parts
- batteries, cables, AC adaptors, re-
chargeable batteries etc. - are excluded.
Defects which come under warranty will
be made good for the customer at no
charge on production of the receipt. No
further claims can be entertained. The
costs of transport in both directions will be
borne by the customer should the equip-
ment be located anywhere other than the
customer’s premises. Warranty claims for
damage during transport can only be en-
forced if the complete original packaging
was used in transit and the goods con-
tained are secured and fixed into position
in their original condition. All the packaging
should therefore be retained.
A claim under warranty will not be hon-
oured if the equipment is opened by per-
sons not expressly authorised by seca to
do so.
We would ask our customers abroad to
contact their local sales agent in the event
of a warranty matter.
www.scaleman.com is your Authorized Seca Dealer
www.balances.com is your Authorized Seca Dealer
Other manuals for 763
2
Table of contents
Other Seca Scale manuals