DT4041C DUAL TRUSS CONTAINER SHELTER
MAIN SPECIFICATIONS :
Overall assembled size : W12 x L12 x H4.5 (m) / W40 x L39.37 x H15 (ft)
Width : 12 m / 39.37ft
Length : 12 m / 39.37ft
Ridge peak height : 4.5 m / 15ft + container height
Shoulder wall clearance height : 1.05m / 3.4ft

www.tmgindustrial.com 2/32 TOLL FREE:1-877-761-2819
PRIOR TO ASSEMBLY
Please read the instructions carefully before installation. It is very important to follow your local safety
regulations and industry standards during installation. Regulations may include but are not limited to:
Safety helmets, protective eyewear, and clothing
Safety harnesses for all elevated workers
Proper ladder, cage, and safety operation
Check all components and parts before installation. All parts are marked with a part number, please refer to the
parts list to make sure you have all parts.
Choose a day with low or no wind to install, assembly is hard in heavy wind. Do not make any alterations to the structure.
Do not hang any weights on the frame during installation, including parts. We are not responsible for any damages or
injuries caused by inappropriate installation, unauthorized modifications or extreme weather.
This building is not intended for human occupancy.
It is recommended to tape or add foam/rubber on the frame where joints connect and where it touches the cover. This
will help extend the life span of the cover.
Read the following item list carefully and count the number of items to ensure that all parts are included prior to setup.
INSTALLATION STEPS
REVIEW THE WHOLE STRUCTURE AND CHOOSE THE PROPER INSTALLATION SITE
Choose a solid flat level ground area to set up the building. Do not install the building on soft ground, wetland, uneven
surfaces, sloped surfaces, or on top of structures that are not rated to hold its weight.
We strongly recommend that you put the containers on hard foundations before installing the shelter.
Be aware of the surrounding area. Do not set up the building near snowdrifts, open flames or exposed electrical wires. Do
not keep heat sources near the fabric cover. Keep the building surroundings clear at all times.
Check the parts list below to make sure all parts are received prior to assembly.

www.tmgindustrial.com 3/32 TOLL FREE:1-877-761-2819
TMG-DT4041C PART LIST
PARTS
CODE PICTURE DESCRIPTION LENGTH QTY
1
Peak arch tube
(for 3 middle trusses ) L2509mm 3
1A Peak arch tube
(for front and rear truss) L2509mm 2
2
Upper rafter tube
(middle truss) L1996mm 6
2A Upper rafter tube
(front and rear truss) L1996mm 4
3 Lower rafter tube
(for middle truss) L2898mm 6
3A Lower rafter tube
(for front and rear truss) L2898mm 4
4
Sidewall tube
(middle truss) L2555mm 6
4A Sidewall tube
(for front and rear truss) L2555mm 4
5 Roofpurlin
(horizontal tube) φ58x3040mm 28
6 Baseplates for middle truss W200xL340mm 6
6L Baseplate for front and rear truss left
corners W200xL340mm 2
6R Baseplate for front and rear truss
rightcorners W200xL340mm 2
7 Top cover tension tube
(for both bottom sides)
φ32x1993mm
φ32x500mm
12
2
8 Ridge steel tension cables
(front and rear trusses) φ8x3500mm 24

www.tmgindustrial.com
9
10
11
12
13
14
15
16
17
18
www.tmgindustrial.com
4/32
TOLL FREE:1
Cable connection plate
W90xL90mm
Ratchets
Tie down straps
(for #10 and front and rear arches)
W38xL800mm
Hex bolt and nuts
M1
Self locking bolt and nuts
M10
Tension tube end water plug
φ
Plastic hose
(in grooves at both ends of #17) φ
25
Connector (for connection #15)
φ
Roof fabric tarp cover
Scratch resistant tape
TOLL FREE:1
-877-761-2819
W90xL90mm
28
3T 34
W38xL800mm
34
M1
2x30mm 160
M10
x80mm 35
φ
32mm 4
25
x4000mm 10
φ
25mm 8
1
L10m 2

www.tmgindustrial.com 5/32 TOLL FREE:1-877-761-2819
STEP 1 : REVIEW THE WHOLE STRUCTURE AND CHOOSE THE PROPER INSTALLATION SI.
NO.
PART QTY
6 6
6L 2
6R 2

www.tmgindustrial.com
STEP 2 : INSTALLATION OF FRON
T AND REAR TRUSSES
NO. PART
1A
2A
3A
www.tmgindustrial.com
6/32
TOLL FREE:1
T AND REAR TRUSSES
.
QTY
NO.
PART
1x2
4A
2x2
12
2X2
TOLL FREE:1
-877-761-2819
QTY
2x2
24x2

www.tmgindustrial.com
STEP 3 : STALLATION (3) MIDDLE
TRUSSES
NO. PART
1
2
3
www.tmgindustrial.com
7/32
TOLL FREE:1
TRUSSES
.
QTY
NO.
PART
1x3
4
2x3
12
2x3
TOLL FREE:1
-877-761-2819
QTY
2x3
24x3

www.tmgindustrial.com 8/32 TOLL FREE:1-877-761-2819
STEP 4 : WRAP (#18) AROUND THE SHARP POINTS OF THE JOINT TO AVOID FRICTION BETWEEN THE FABRIC AND
THE INTERFACE.
NO.
PART QTY
18 2

www.tmgindustrial.com
STEP 5 : PUT UP ALL TRUSSES.
NO. PART
5
8
9
www.tmgindustrial.com
9/32
TOLL FREE:1
QTY
NO.
PART
7
12
12
13
14
TOLL FREE:1
-877-761-2819
QTY
16
14

www.tmgindustrial.com
STEP 6 : TENSION CABLE INSTAL
LATION
INTERVAL.
NO. PART
5
8
9
www.tmgindustrial.com
10/32
TOLL FREE:1
LATION
. ALL CABLES ARE DIAGONALLY INSTALLED ON
EACH SIDE OF THE
QTY
NO.
PART
21
12
12
13
14
TOLL FREE:1
-877-761-2819
EACH SIDE OF THE
QTY
24
21

www.tmgindustrial.com
STEP 7 : INSTALL ROOF COVER.
NO.
17
www.tmgindustrial.com
11/32
TOLL FREE:1
PART QTY
1
TOLL FREE:1
-877-761-2819

www.tmgindustrial.com
STEP 8 : TENSION THE COVER
ON THE FRAME FROM SI
NO. PART
7
10
11
www.tmgindustrial.com
12/32
TOLL FREE:1
ON THE FRAME FROM SI
DE TO SIDE.
QTY
NO.
PART
2
14
34
15
34
16
TOLL FREE:1
-877-761-2819
PART
QTY
4
10
8

www.tmgindustrial.com 13/32 TOLL FREE:1-877-761-2819
DT40FW9 WITH MECHANICAL ROOL UP DOOR AND STEEL MANDOOR
MAIN SPECIFICATIONS :
Overall assembled size : W12 x H7.4 (m) / W39.37x H24.28 (ft)
Width : 12m / 39.37ft
Height : 7.1 m / 24.28ft
Front door:4.6x4.5(m)/15.09x14.76(ft)

www.tmgindustrial.com
PARTS
CODE
PICTURE
7A
7B
7D
9
9A
9B
9C
9D
10A
10B
10L
10R
11L
11R
11A
12
www.tmgindustrial.com
14/32
TOLL FREE:1
TMG-DT40FW9 PART LIST
DESCRIPTION
Baseplate
W150xL200mm
Baseplate
W150xL200mm
Baseplate of front door frame
W150xL200mm
Side vertical tube
Side door left tube
Side door right tube
Side door
W925xL2005mm
Side vertical tube
Lower vertical tube
Lower vertical tube
Front vertical door rail
(left side lower part)
Front vertical door rail
(right side lower part)
Front vertical door rail
(left side upper part)
Front vertical door rail
(right side upper part)
Middle vertical tube
Upper vertical tube
TOLL FREE:1
-877-761-2819
LENGTH QTY
W150xL200mm
1
W150xL200mm
3
W150xL200mm
2
L2925mm 1
L2027mm 1
L2027mm 1
W925xL2005mm
1
L2925mm 1
L2945mm 1
L2945mm 1
L2625mm 1
L2625mm 1
L2370mm 1
L2370mm 1
L2014mm 2
L1616mm 2

www.tmgindustrial.com
13
14A
14B
15A
15B
16A
17
18
18A
18B
19
20
21
23A
23B
23C
23D
www.tmgindustrial.com
15/32
TOLL FREE:1
Upper vertical tube
Bottom tension bar
Front door hand winch crossing tube
Transverse tube
Side door upper tube
Middle transverse tube
Upper transverse tube
Upper transverse tube
Front roll up door dropping tubes (to
connect #18B)
Front roll up door dropping tubes (to
connect #18A)
Upper transverse tube
Support tube
Expansion bolts
16x150mmφ
Wire rope for front door hand winch
Right pulley system for front door
Left pulley system for front door
Roll up door hand winch
TOLL FREE:1
-877-761-2819
L2146mm 1
L1590mm 3
L1635mm 1
L1781mm 2
L1642mm 1
L1635mm 2
L2500mm 1
L2920mm 2
L2356mm 7
L2359mm 7
L2666mm 1
L2985mm 3
16x150mmφ
16
15m 1
L150mm 1
L150mm 1
(1200 lb) 1

www.tmgindustrial.com
24C
24D
25
25A
25B
25C
27
29
29A
30
33
34
34A
38
www.tmgindustrial.com
16/32
TOLL FREE:1
Front vertical door rail connection plate
Front vertical door rail end plate (floatable
to keep door rail straight)
Tube clamps
Tapping screw
Pressing plate
Pressing plate
Hex bolt and nuts
Hex bolt and nuts
Hex bolt and nuts
Tube end water plug
Braided rope
Front truss fabric cover panel
W12.1xL7.6m
Front roll up door cover panel
W4560xL5170mm
Front fabric tarp secure pin
TOLL FREE:1
-877-761-2819
L240mm 2
L220mm 2
φ58 19
#12x25mm 68
L2000mm 6
L1000mm 1
M10x50mm 19
M8x90mm 29
M10x70mm 26
φ32 6
100m 1
W12.1xL7.6m
1
W4560xL5170mm
1
L200m 1

www.tmgindustrial.com
STEP 1 :
REVIEW THE WHOLE STRUCTURE AND CHOOSE THE PROPER INSTALLATION SI
Place the containers making sure they are parallel and the correct width apart
equal. Baseplates
must be bolted firmly
Installation diagram of expansion bolt.
NO.
PART
7A
7B
www.tmgindustrial.com
17/32
TOLL FREE:1
REVIEW THE WHOLE STRUCTURE AND CHOOSE THE PROPER INSTALLATION SI
TE.
Place the containers making sure they are parallel and the correct width apart
the diagonal X and Y must be
must be bolted firmly
with expansion bolts,
It is concrete expansion bolt.
Installation diagram of expansion bolt.
QTY
NO.
PART
1
7D
3
21
TOLL FREE:1
-877-761-2819
TE.
the diagonal X and Y must be
It is concrete expansion bolt.
QTY
2
12

www.tmgindustrial.com 18/32 TOLL FREE:1-877-761-2819
STEP 2 : FRONT TRUSS TO COMPLETE.

www.tmgindustrial.com
NO.
PART
9
9A
9B
9C
9D
10A
10B
10L
10R
11L
11R
11A
12
13
14A
14B
15A
www.tmgindustrial.com
19/32
TOLL FREE:1
QTY
NO. PART
1
15B
1
16A
1
17
1
18
1
19
1
21
1
23B
1
23C
1
24C
1
24D
1
25
2
25A
2
27
1
29
3
29A
1
30
2
TOLL FREE:1
-877-761-2819
QTY
1
2
1
2
1
4
1
1
2
2
13
10
13
29
24
6
Table of contents
Other TMG Shelter manuals

TMG
TMG TMG-ST4081E User manual

TMG
TMG PRO Series User manual

TMG
TMG ST3080V-1.0 User manual

TMG
TMG TMG-LCP16 User manual

TMG
TMG TMG-DT5040CG User manual

TMG
TMG TMG-DT40FW8 User manual

TMG
TMG TMG-MS2119 User manual

TMG
TMG TMG-ST2031V User manual

TMG
TMG TMG-DT3063-PRO User manual

TMG
TMG TMG-ST3080E-1.0 User manual
Popular Shelter manuals by other brands

Gazebo penguin
Gazebo penguin SAS11X12FF instruction manual

ABRIS MONDIAL
ABRIS MONDIAL MINI SINGLE SLOPE WALKWAY instructions

X-METAL
X-METAL 13457 Assembly instructions

In the Garage
In the Garage Ultimate Car Shield instructions

Game Day Gear
Game Day Gear SKY 110130 quick start guide

Inkema
Inkema ABRE instruction manual