2N EASYGATE UMTS User manual

ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

Dearcustomer,
Let uscongratulateyou on having purchased the EasyGateUMTSDatasystem. This
newproducthasbeendeveloped andmanufacturedtoprovide the maximumutility
value,qualityand reliability.Wehope you willbe fullysatisfied withthisUMTS/GSM
gatewayforalong time.Therefore,useyourEasyGateUMTSDataforpurposesithas
beendesignedandmanufacturedfor,inaccordanceherewith.
The manufacturerreservesthe righttomodifythe productinordertoimproveits
qualities.
Safety Precautions
DonotswitchonEasyGateUMTSDatainthevicinityofmedicalapparatusesto
avoidinterference.Theminimumdistanceofthe antenna and pacemakers
shouldbe 0.5m.
Donot switchonEasyGateUMTSDataaboardof aplane.
DonotswitchonEasyGateUMTSDatanearpetrolstations,chemicalfacilitiesor
siteswhereexplosivesareused.
Anymobiletelephone useprohibition basedon RFenergyradiation appliesto
EasyGateUMTSDatatoo.
EasyGateUMTSDatamaydisturbthe functionof TVsets,radiosetsandPCs.
Warning!EasyGateUMTSDatacontainscomponentsthatcan be swallowed by
small children (USIMcard, antenna,etc.).
The voltagevalue mentioned onthe adaptermaynotbe exceeded.If you
connectEasyGateUMTSDatatoanotherpowersupply,makesurethatthe
voltage valueisinthe acceptablerange.
When yourEasyGateUMTSDatacomestothe end ofitsoperationallife,
disposeofitinaccordancewithapplicableregulations.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

UserManualVersions
VersionAmendmentstoEarlierVersions
1.00 •The UserManualappliestoEasyGateUMTSDataFWVersion 2.20K
Upgrade
The manufacturercontinuouslymeetscustomerrequirementsbyimproving the
firmware.Forthe latestEasyGateUMTSDataprocessorfirmware,programming tool
and UserManualsee www.2n.cz.Foradetailed description oftheEasyGateUMTS
Datafirmwareupgraderefertothe sectiondevoted tothe PCprogramming tool.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

PackingList
An EasyGateUMTSData deliverycontainsthefollowingitems:
Item Numberof
Pieces
EasyGateUMTSData 1 pc
Antenna fordirect connection 1pc 1)
MagneticAntenna withcoaxcable 1pc 1)
Supplyadapter 1pc
Telephone cable 1pc
PC-connection USB cable 1pc
PC-connection serialcable(onlyforgatewayupgradeand
programming) 1pc
Dowels 2pcs
Bolts 2pc
CD-ROMwithUserManualand software 1 pc 2)
Quick Installation Guide +mountingpattern 1pc
Warrantycertificate 1pc
Notes:
1)The deliveryincludesan antenna tobe connected directlytothe EasyGate
UMTSDataSMAconnector.Anantennawithacableshouldbe used when
UMTS/GSMsignalispoororincaseof interferencewithotherdevices.
2)Enclosed software:
•EasyGateUMTSDataPCManager
•UserManualinpdf format
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

CONTENTS
1. EASYGATEUMTSDATAPURPOSE..................................................................................5
1.1. BASIC FUNCTIONS...................................................................................................................... 5
1.2. ADVANTAGESOF EASYGATE UMTS DATA USE............................................................................ 5
2. INSTALLATION....................................................................................................................6
2.1. PROPER LOCATION.................................................................................................................... 6
2.2. EXTERNAL ANTENNA CONNECTION ............................................................................................. 7
2.3. USIMCARD INSTALLATION......................................................................................................... 7
2.4. CONNECTORDESCRIPTION......................................................................................................... 8
2.5. TELEPHONE LINE CONNECTION................................................................................................... 8
2.6. POWER SUPPLY CONNECTION.................................................................................................... 8
2.7. PC CONNECTION....................................................................................................................... 8
3. EASYGATEUMTSDATASTATUSINDICATION...............................................................9
3.1. INDICATION LEDS...................................................................................................................... 9
3.2. TELEPHONE LINE TONES ............................................................................................................ 9
4. USIMCARD PINPROTECTION........................................................................................11
4.1. PIN ENTERING BY PCMANAGER ............................................................................................... 11
4.2. PIN ENTERING VIA TELEPHONE LINE......................................................................................... 11
4.3. AUTOMATIC PIN ENTERING....................................................................................................... 11
5. VOICEFUNCTION.............................................................................................................12
5.1. OUTGOING CALL...................................................................................................................... 12
5.2. INCOMING CALL ....................................................................................................................... 12
5.3. AUTOMATIC CALL ("BABY CALL")............................................................................................... 13
5.4. TARIFF PULSES 16 OR 12 KHZ.................................................................................................. 13
5.5. CONFIGURATIONOFNETWORKSERVICES .................................................................................. 13
5.6. CALL FORWARDING .................................................................................................................. 14
5.7. CALL WAITING.......................................................................................................................... 15
5.8. CALL HOLD .............................................................................................................................. 15
6. USBINTERFACE...............................................................................................................17
6.1. USB INTERFACEDRIVERSINSTALATION..................................................................................... 17
6.2. CONNECTIONSETTINGSAND START........................................................................................... 17
6.3. COMBINATIONOF USB TRAFFICWITHVOICECALLS .................................................................... 17
7. COM–SERIALINTERFACE.............................................................................................17
7.1. PROGRAMMING........................................................................................................................ 18
8. EASYGATEUMTSDATAPARAMETERPROGRAMMING..............................................19
8.1. TELEPHONE LINEBASED PROGRAMMING................................................................................... 19
8.2. PC BASED PROGRAMMING........................................................................................................ 20
8.3. PARAMETER TABLES................................................................................................................ 23
9. TROUBLESHOOTING........................................................................................................35
10. LISTOFABBREVIATIONS................................................................................................36
TECHNICALPARAMETERS–UMTSEASYGATE:................................................................37
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

5
1.EasyGate UMTS Data purpose
1.1.BasicFunctions
•The primarypurposeof EasyGateUMTSDataistotransmit voicebetween aUMTS
orGSMnetworkand an attached FXO-interfaceterminal(PBX,telephone,
answering machine,etc.).
•You can establishfastinternet HSDPA connectionorGPRSconnection.
•You can send an SMStoapre-programmed numberusing theSMSsending input.
•EasyGateUMTSData can’testablishdata/faxconnections!
1.2.AdvantagesofEasyGate UMTSDataUse
•Call costcutting –byforwarding UMTS/GSMcallstoEasyGateUMTSDatayou save
alot on PSTN–UMTS/GSMcalls.
•Easyinstallation –EasyGateUMTSDataisdesigned forimmediateusewithout
programming.
•Yougetall youneedinthedelivery –yourEasyGateUMTSDatadeliverycontains
all you need tooperatethe system(the powersupplyadapter,telephone cable,PC
serialcableand CD-ROMwithsoftware).
•Solutionforsites withouttelephonelines –suchasmountainchalets,exhibitions,
conferences, etc.
•CLIP -EasyGateUMTSDataisequipped withthe FSK-based CLIPfeature,soifa
terminalcapableof receiving the CLIPisused you knowthe caller‘snumber.
•Fastinternetconnection –EasyGateusesHSDPAforinternetconnection (max
speed 7.2Mbit/s).HSDPA connection and voicecallscan runsimultaneouslyon
gateway
•SMSsendinginput –simplysend an SMStoapre-programmed numberbyclosing
the contact. Recommended foreasysupervision, simplesecuring, etc.
•Radiationhazardminimization –you arenotexposed toadirecteffectofthe
antenna RFelectromagneticfieldwhiletelephoning asopposed tomobiletelephones.
•Full UMTS/GSMcoverage –UMTS2100MHzand GSM850/900/1800/1900MHz.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

6
2.Installation
2.1.ProperLocation
•EasyGateUMTSDataisdesigned forverticalmountingon suspensionholes(use
the mounting pattern).Thisposition isthe bestforsignalreception becausea
verticalantenna isused.EasyGateUMTSDatacan be operatedinthe horizontal
positiontoo wherethe UMTSsignalisgood.
•Install EasyGateUMTSDatawithrespecttotheUMTSsignalstrength.
•PlaceEasyGateUMTSDataoutofrange ofsensitivedevicesand human bodiesfor
electromagneticinterferencereasons.
•Fortheallowed rangeofoperatingtemperaturesrefertothe“Technical
Parameters”.
•It isimpossibletooperateEasyGateUMTSDataon placesexposed todirectsolar
radiation ornearheat sources.
•EasyGateUMTSDataisdesigned forindooruse.It maynotbe exposed torain,
flowing water, condensed moisture, fog, etc.
•EasyGateUMTSDatamaynotbe exposed toaggressivegas,acidvapours,solvents,
etc.
•EasyGateUMTSDataisnotdesigned forenvironmentswithhigh vibrationssuchas
meansof transport, machine rooms, etc.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

7
2.2.External AntennaConnection
Screwthe antenna enclosed intothe SMAantenna connector.Tightenthe antenna
connectorgentlywithyourhand -neverusewrenches!
The antenna enclosed hasasufficientgainfortrouble-free operationinnormal
conditions.IftheUMTSsignalispoororyouwanttoplaceyourantenna separately
fromEasyGateUMTSData,you can usean antenna withan SMA-connector
terminated cable. Theantenna shouldbe mounted vertically.
The Antenna shallbelocatedwithinthe samebuildingasthemainequipment.
Forantennaand cableparameterssee the “TechnicalParameters“.
2.3.USIMCardInstallation
Usethe modernUSIMcardsdesignedforUMTSnetworks toavoidproblems
Open the USIMcardholderon EasyGateUMTSData’sbackside,inserttheUSIM
cardand closeit. Selecttherequired UMTSproviderand USIMcardservices,suchas
callforwarding,call barring,preferred networks,SMSservicecentre,etc.inyourmobile
phone beforeinsertingyourUSIMcardinEasyGateUMTSData.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

8
2.4.Connectordescription
USB interface
Telephone line
RJ12, 6/2
Powersupplyconnector
DC Jack 2,1mm
RS232C serialline
D-Sub 9pins
2.5.TelephoneLineConnection
2.5.1.PBXConnection
ConnectEasyGateUMTSDatatoafreeCO line ofyourPBX.ConfigureyourPBX in
suchamannerthat UMTS/GSMoutgoing callsarerouted toEasyGateUMTSData.
EasyGateUMTSDataisequipped withthe FSK-based CLIPfunction.If yourPBX is
abletoprocess the caller’sID, you areadvised toenablethisfunction.
2.5.2.TelephoneSet(AnsweringMachine, CoinTelephoneStation)Connection
You canconnectastandardtelephone,answering machine oranyotherFXO-interface
terminaltoEasyGateUMTSData.
EasyGateUMTSDataisequipped witthe FSK-based CLIPand soit isadvantageousto
connect aterminalthat isabletodisplaythe CLI.
2.6.PowerSupplyConnection
EasyGateUMTSDataisfed with10-16VDC.Whereasourceotherthan the included
powersupplyadapterisused,thevoltage range and polarityshownon the EasyGate
UMTSDatapowersupplyconnectorhavetobemaintained.
Donotactivatethe powersupplyuntil the antenna isconnected toEasyGateUMTS
Datatoavoidthe UMTSmoduledamage.
2.7.PCConnection
USB cableforPCconnection isincluded.You can useitforhigh speedinternetaccess
(using HSDPA),forGPRSaccess orforCSDconnection.Included serialcablecan be
used onlyforprogramming and firmwareupgrade ofEasyGateUMTSData.The serial
cableisamodemcablewhereall of the 9pinsare1:1interconnected –incaseyou wanted
touseanother,longercable.Makesurethatalongercableworks properlytoavoiderrors
at high transmission rates.
12 3 4
1
2
3
4
432
1
5
1 2 3 4
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

9
3.EasyGate UMTS Data StatusIndication
3.1.IndicationLEDs
Name Meaning
Powersupply
•Light =EasyGateUMTSDataispowered.
•Flashesoncein2s=HWerror, contact the manufacturer.
UMTS/GSM
network
•Light =registered toUMTS/GSM
•Flashesoncein1s=not registered, USIMcardinserted
•Flashesoncein3s=not registered, USIMcardnot
inserted
•Flashes4timesquickly=enteryourPIN
•Flashes8timesquickly=enteryourPUK
•Flashesquicklycontinuously=allfunctionsareblocked.
YourUSIMdoesn’t correspondtotheoperatorlock
Telephone line
•Nolight =standby
•Flashesquickly=seized line orringing
•Light =call
3.2.TelephoneLineTones
3.2.1.OperationalTones
EasyGateUMTSDatasendstonestothe telephone line toindicatethe linestatus.
Dial tone: continuousorMorseA:
•EasyGateUMTSDataisregistered toUMTS/GSMnetworkand readytoreceive
dialing.
Ringingtone:
•The called subscriber'stelephone isringing.
•The UMTS/GSMnetworktransmitsthistone.
Busytone:
§The busy tone istransmitted inanyof the following cases:
§The USIMcardhasnot been installed.
§EasyGateUMTSDataislogged-out.
§EasyGateUMTSDataislogged-intoaforeign networkbutroaming is
disabled.
§The called numberhastoo manydigits(morethan 30).
§The called numberisbarred.
§The called subscriberline isbusy.
§The called subscriberhashung up (disconnection).
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

10
Dialingendsignaling:
•Dialing receptionhasbeen terminated. Connectionisbeing established.
PINtone:
•Enterthe PINcode.
•Thistone istransmitted upon powerup if the PINhastobe enteredmanually.
PUK tone:
•Enterthe PUKcode.
•Thistone istransmitted upon repeated wrong PINentering attempts.USIMcardis
blocked.
3.2.2.ProgrammingModeTones
Tonesconfirming/refusing the valuesenteredaretransmitted during telephone line
based programming. Eachtonehasadifferent melody.
Confirmation:
•Confirmsthatthe servicepasswordorparameternumberentered iscorrectand
hasbeen accepted.
Refusal:
•Incorrect parameternumber;
•Incorrect parametervalue
•Transmitted when aparameteriscancelled witha .
Saving:
•Parametervalue entered iscorrect and hasbeen saved.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

11
4.USIMCard PINprotection
If aUSIMcardisPIN-protected andthe PINisnotprogrammed inEasyGateUMTS
Data, networkLEDindicatesthe stateand thePINtone istransmitted on telephoneline.
4.1.PINEnteringbyPCManager
Likeotherparameters,the PINcodecan beenteredusing aPCprogramming tool.
The PINwillbe entered automaticallyuponnext EasyGateUMTSDatapowerup.
4.2.PINEnteringviaTelephoneLine
ToenterthePINviaatelephone lineusing theDTMF:
1.Hookoff thetelephone, youcan hearthe PINtone.
2.Enterthe PINusing the DTMF;tocancelthe wrong PINhang up before
sending a .
3.Toconfirmentera .
4.If you hearthe busy tone inawhile(afewseconds), you haveentered the PIN
correctly. Hookon and wait forregisteringtothe UMTS/GSMnetwork.
5.If youhearthePINtone againinawhile,youhaveenteredawrongPIN.Re-
enterthePIN.
6.If you hearthe PUKtone inawhile,you haveentered awrong PINand the
USIMcardisblocked. Usethemobilephonetounblock theUSIMcard.
Acorrectlyentered PINisstoredinEasyGateUMTSData’smemoryasifyou had
programmed itusingthePCManager.ThePINwill be entered automaticallyupon the
next EasyGateUMTSDatapowerup.
4.3.AutomaticPINEntering
You need notenterthePINuponpowerup if it isstored inEasyGateUMTSData–it
isentered automatically.Thisfunction isconvenientincaseofpowerfailure;EasyGate
UMTSDataisoperableinashorttimeafterpowerrecoverywithoutanyinterventionby
the operating staff.
Caution! One PINentering option isexhausted bythe attempttoenterthe PN
automaticallyuponUSIMcardorPINchange.If wrong, the automaticallyenteredPINis
cleared fromthe internalmemorytoavoidanotherfalseattemptupon nextpoweron.
Therearestill twomanualPIN-enteringattemptsaftersuchunsuccessfulautomatic
entering.Topreventthe unsuccessfulautomaticPINentering,deleteorprogram
properlytheEasyGateUMTSDataPINusing the PCManagerinthe caseofUSIMcard
change.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

12
5.Voicefunction
Outgoing and incoming callestablishing proceduresforan analog telephoneare
describedforillustration.The proceduresarethe sameforthe EasyGateUMTSData-
PBX connection,justremembertoprogramcall routing toEasyGateUMTSData
properly.Check EasyGateUMTSData’sfunction byconnecting atelephone before.
SupposethataUSIMcardhasbeeninserted,the PINcode entered ornotrequired
the antenna connected and EasyGateUMTSDataregistered toUMTS/GSMnetwork–
the networkLEDispermanentlyon andyou can hearthe dialtone upon off-hook.
5.1.Outgoing Call
1.Hookoff thetelephone, youcan hearthe dialtone and the LineLEDstartsflashing.
2.Dialthe required UMTS/GSMsubscribernumber.SinceEasyGateUMTSData
receivestone dialing bydefault, selectthe DTMFmode.If yourtelephone transmits
pulsedialing only,programEasyGateUMTSDatatoreceivepulsedialing.The
delaybetween digitstobe dialed maynotexceed 5s(programmableparameter).The
numberisevaluated ascompleteand transmitted tothe networkafterthistimeout.
3.Ashortdelayfollowsthe last-dialed digitforEasyGateUMTSDatatoawaitfurther
dialing. Then, thedialing end issignaledand connection isestablished.
4.If the called subscriberisavailable,you can hearthe ringing tone.If not, you can
hearthebusy tone oranyofthe provider’smessages.
5.Whenthe called subscriberanswersthecall,acallisestablished.The Line LEDis
permanentlyonduringthe call.
6.Hang up toterminatethe call.The Line LEDgoesoff. If the called subscriberisthe
firsttohang up,you canhearthe busy toneand hang up.
5.2.Incoming Call
1.Ringing signalsan incoming call.TheLine LEDflashesduring ringing.If
programmed so, EasyGateUMTSDatatransmitsthe CLIPbyFSK between the first
and secondrings. Advanced telephonesetsareabletodisplaytheCLI.
2.Hookoff the phone toestablishthe call.TheLine LEDispermanentlyon during the
call.
3.Hang up toterminatethe call.The Line LEDgoesoff. If the called subscriberisthe
firsttohang up,you canhearthe busy toneand hang up.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

13
5.3.AutomaticCall("BabyCall")
If the BabyCall function isenabled,apre-programmed periodoftimeiscounted
downafteroff-hook.If you do notstartdialingwithinthistimeout, EasyGateUMTSData
signalsdialing endandstartsestablishingacalltothepre-programmed number
automatically–fromnowon EasyGateUMTSDatabehavesasifastandardoutgoing
callhad beenestablished. Anydialing during the BabyCalltimeout cancelsthisfunction
and astandardoutgoing callcan be made.
5.4.Tariffpulses16or12kHz
EasyGateUMTSDatahastariff pulsetransmitter.You can usetariff pulsesfor
outgoing callpricing.EasyGateUMTSDataofferpseudo tariff only–tariff metering
doesn’tcorrespond torealpriceofcall,tariff pulsesaretransmitted according to
programmed parametersand callduration.You mustprogramspecificparametersin
calltabletoset tariffmetering fordifferentprefixesof dialed numbers.
You can alsoprogramEasyGateUMTSDatatotransmittariffpulsesascall
connect/disconnectsignaling ifyourPBX cannotreceivetelephoneline polaritychange
signaling.
5.5.Configuration ofnetworkservices
EasyGateprovidessomeofnetworkservicestoimprovepossibilityofusage.The
configuration isdonebystandardStar-Hashcodesyou canknowfrommobilephones.
Toconfiguretheseservices:
1.Hookoff thetelephone, youcan hearthe dialtone.
2.Enterthe Star-Hashcode described below.
3.Wait forinformation tone. You maywait about3seconds.
4.Hookon.
Information tones:
Confirmation-OK:
•Confirmsthat the servicewasconfigured correctly.
Confirmation-bad:
•Servicewasnot correctlyconfigured
•Serviceisn’t activatedbyyourprovider
Confirmation-service activated:
•Confirmsthat the servicewasconfigured correctlyand theserviceisactivated.
Confirmation-service deactivated:
•Confirmsthat the servicewasconfigured correctlyand theserviceisdeactivated.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

14
5.6.Call forwarding
Forforwarding activation you mustspecify<Telephonenumber>the callswillbe
forwarded to.You mayspecify<Calltype>,ifyouwanttoforwardspecifiedcalltype
only.You mayspecify<Delaytime>insecondsforforwardingif no answertoo.
Description of <Calltype>fieldcodes:
Voice:
Data:
Fax:
5.6.1.Call forwardingunconditional
If activated,incoming callswillbealways forwarded tothe configuredtelephone
number.
Activation forallcalltypes:
<Telephone number>
Activation forselected calltype:
<Telephone number> <Calltype>
Deactivation:
Statuscheck:
5.6.2.Call forwardingifbusy
If thisoptionisactivated, incoming callswillbeforwarded tothe configured telephone
numberif thereiscallinprogress on EasyGate.
Activation forallcalltypes:
<Telephone number>
Activation forselected calltype:
<Telephone number> <Calltype>
Deactivation:
Statuscheck:
5.6.3.Call forwardingifnoanswer
If activated,incoming callswillbe forwardedtothe configured telephone numberif
incoming callisn’tanswered during specifiedtimeout. Default timeout is20seconds.
Activation forallcalltypes:
<Telephone number>
Activation forselected calltype:
<Telephone number> <Calltype>
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

15
Activation forallcalltypesandspecified delaytime:
<Telephone number> <Delaytime>
Activation forselected calltypeand specified delaytime:
<Telephone number> <Calltype>
<Delaytime>
Deactivation:
Statuscheck:
5.6.4.Call forwardingifnotaccessible
If activated,incoming callswillbe forwardedtothe configured telephone numberif
yourEasyGateisnot accessibleintheGSMnetwork.
Activation forallcalltypes:
<Telephone number>
Activation forselected calltype:
<Telephone number> <Calltype>
Deactivation:
Statuscheck:
5.7.Call waiting
If the callwaitingisactivatedthe incoming callisn’trefuseifthereiscallinprogress
on EasyGate.If thereistheotherincoming callduring connected callitwillbe indicated
bytone. See 5.8. formultiplecallsmanagement.
Activation:
Deactivation:
Statuscheck:
5.8.Call hold
Check ifyournetworksupportsthe servicebeforeyou useit.
ThisservicerelatestoCallwaiting described in5.7.If thereiscallwaitingon the line,
you havemorepossibilitieswhattodo.Everyaction ismade byFLASHand DTMF
code:
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

16
Toterminateallheldcalls,orreject waiting calldial:
Toterminatingactivecalland accept the heldorwaiting calldial:
Toplacethe activecallonholdand acceptthe heldorwaiting call(switching
between twocalls)dial:
Toplaceallheldcallstoactivecallsand setupconferencecalldial:
Toconnectthe twocalls(activeand held)and disconnectthe EasyGatefromboth
callsdial:
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

17
6.USBinterface
You can useHSDPA orGPRSinternetaccess orCSDconnection when connecting
YourEasyGateUMTSDATAwithPCviaUSBinterface.
6.1.USBinterfacedriversinstalation
It isneededtoinstallUSB modemdriversforproperlyfunction ofUSB interface.
When the gatewayisconnected withPCforthefirst timethe Windowsoperating system
willfind automaticallythe newhardware.Choosethe Find driversinPCoption and set
the drivers’directorypath.Themodemdriversareon included CD indirectory
Data\EasyGate\Modemdriver.FirstYou need tounzipthe file 3GUSB Modem
Drivers.zip on Yourharddrive.Choosetoinstalldriversanywaywhen warning “driver’s
manufacturerisunknown”or“the driverisnotsigned”appears.You shouldinstall
driversforthe following devices:
-Telit HSDPA USB Modem
-Telit Diagnostics Interface
-Telit AuxiliaryPort
All thisdevicescan be found inwindowsdevicemanager(inModemssection and
Ports(COMand LPT)section).If the Windowsfunction ofautomaticallyhardware
changesfinding isdisabled open Windowsdevicemanager,findnewhardwarewithout
drivers(marked withorange exclamation mark),click on itwithrightmousebutton and
chooseinstall driveroptions.Followthe instructionsuptoinstalldriversforallthree
interfaces.
6.2.Connectionsettingsandstart
Forinternetconnection createnewtelephone modemconnectionsusing Telit
HSDPA USB modem.Set up the modemusinginformation fromYourmobileoperator.
6.3.CombinationofUSBtrafficwithvoicecalls
WhenusingHSDPA internetaccess thevoicecallsarenot affected.You can usethe
gatewayforHSDPA connectionand voicecallsatthesametime.When using GPRS
connection the gatewayisnotaccessibleforincoming calls,outgoing callsinterruptthe
GPRSconnection. AftercallendstheGPRSconnection isrenewed.
7.COM–SerialInterface
The completeserialinterfaceRS-232Con a9-pinconnectorisidenticalwithany
externalmodem.
The transmissionrateis115200bps.Donotchange it.(EasyGateUMTSData
doesn’tsupportsautobauding.).Thetransmission setup mustbe 8bits,no parityand
one STOPbit (8N1).
EasyGateUMTSData’scentralprocessorusesthesameinterfaceforestablishing
callsand soitmusthavethepossibilitytoblock an externalserialinterface-all PCSW
mustprovide transmissionhardwareflowcontrol(HWhandshaking).COMcanbe used
forEasyGateUMTSDataprogramming
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

18
7.1.Programming
Install the EasyGateUMTSDataPCManagersoftwareavailableon the included CD-
ROMintoyourPC.
The programisdesigned forEasyGateUMTSDataparameterprogramming.It can
read configurationdatafromthe memoryand storetheminEasyGateUMTSData.
Moreover,allparameterscan besaved inyourPCfileforbackup orsaving intoanother
EasyGateUMTSDatasystem.
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

19
8.EasyGate UMTS Data ParameterProgramming
All EasyGateUMTSDataparametershavesuchdefault valuesthat meetmost users’
demandsand neednotbe changed.Tochange EasyGateUMTSDataparametersin
spiteof that, you caneither:
•UseaPCwiththe PCManagerinstalled.All functionssupported byEasyGate
UMTSDatacan be setusing thePC.
•Orusethe DTMFprogramming on atelephone line.Notallfunctionscanbe setin
thisway.
8.1.TelephoneLinebasedProgramming
1.Hookoff thetelephone,you canhearthedialtone orthe busy tone,andtheLine
LEDstartsflashing.
2.Entertheservicepassword(12345bydefault, can be changed)withtheDTMF;to
cancelawrong passwordhang up beforesendingthe character.
3.Toconfirmpasswordentera .
4.If you haveentered acorrectpassword,you heartheconfirmation tone.Ifnot, the
dialednumbermaybe senttothe networkasacall.Topreventthis,hang upwhen
you do not hearthe confirmation tone.
5.EasyGateUMTSDatashallremaininthe programming mode untilhang-up.
6.Enterthe numberofthe parametertobe programmed and press a .If the
parameternumberiscorrect,you can heartheconfirmationtone,ifnot,you getthe
refusaltone andcan re-entertheparameternumber.
7.When the parameternumberisconfirmed,enterthe allowed parametervalue and
press a .If the parametervalue isintheallowed range,youcan hearthe saving
tone,ifnot, you getthe refusaltone.You canenteranotherparameternumberin
eithercase.
Numericparametersareprogrammed using numbersinunitsincluded inthe
parameterdescription. ForYES/NO parametersuse forYES and forNO.
Tocancelanyprogramming step intheprogramming mode,press a .Having
done so,you can hearthe refusaltone and can enteranewparameternumber.
Parametersaresaved when the savingtone istransmitted.Hang up toquit
programming.
Example:
Passwordentering,OK
Transmissionvolumeparameter,OK
Settomediumlevel,saved
Non-existent parameternumber,refusal
ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM
Table of contents
Other 2N Gateway manuals