16. Internal Forced Lock
15. External Forced Lock
User Guide
RFID Key Tag / Fingerprint / PIN Code / Key
YDD724A
23. Master Mode
17. Alarm
18. 3 Minute Lock Out
19. Unlocking Door with Fake Code
Intrusion Alarm :
The alarm goes off when someone forces the door open.
For example, In case of an intrusion by opening a gap
in the door while the door is locked.
Broken Alarm(Breakage Alarm) :
The alarm goes off when the front part is
completely separated from the main set. For example,
forced removal of external product (front body).
Turn off Alarm
There is no limitation for
digits of Fake Pin Code.
Disable 3-minute Lock Out
All access mode from the external side are disabled for 3 minutes to deter
unauthorized access.
Press the Open/Close button.
Open the door with mechanical key.
Press button.
Enter the registered User Code.
Scan the registered fingerprint.
Press and hold the O/C Button for 5seconds.
Touch the registered RFID Key Tag.
20. Power supply
21. Emergency power supply for discharged batteries
One-on-one real life size
1.5V(LR6) Alkaline AA Battery
It may sustain 1 year if used 10 times
a day. (Users are advised to use
authentic Alkaline batteries.)
*
Kindly dispose used batteries.
•
Do not install the digital door lock in an outdoor environment.
•
Do not attempt to disassemble the digital door lock by your self.
By doing so, you may get an electronic shock and damage the product.
•
Do not use force with a tool onto the product.
•
Make sure to lock the door tight when you go out.
•
Do not use water and any type of solvent to clean the product such as
gasoline or benzene as they can cause damage to electronic circuit,
deterioration and or paint peel-off.
•
It is recommended to change User Code on a regular basis.
•
In manual lock mode, make sure to double check whether the door is
securely locked.
•
When External Forced lock is set and unlock the door, the alarm will be
activated.
•
Do not use rechargeable batteries. Only alkaline batteries are recommended.
•
Make sure to follow the above instructions to avoid any injuries.
•
It cannot be guaranteed in a special conditions & environment such as
water condensation, seaside.
•
Warranty will not cover- exposure to dampness, excessive heat,
excessive humidity and other extreme environmental conditions,
corrosion, damage beyond repair, rusting, unauthorised modifications,
unauthorised repairs, neglect, accident, alteration, acts of God,
spillage of liquid or food particles.
Master mode is a mode in which only the administrator can set the door lock and provide
access to other users. 100 users passwords, 100 users RFID key tags,100 users fingerprint and
individual registration and deletion of one-time passwords enable efficient management of visitors.
Change
Mode New Again
Switch to master mode (from normal mode)
PIN CODE
UPIN CODE
MPIN CODE
M
Change
Mode New Again
Switch to normal mode (from master mode)
PIN CODE
UPIN CODE
U
OR
Registr
-ation New Again
Master Pin Code Change
PIN CODE
M
PIN CODE
M
PIN CODE
M
Delete
OR
Registr
-ation
User Code
PIN CODE
U
UN
OR
UN
PIN CODE
M
Up to 100 Users
Only 1 User
Delete
OR
Registr
-ation
Fingerprint
UN
OR
UN
PIN CODE
M
Up to 100 Users
Delete
Registr
-ation
Onetime Code
OR
OR
PIN CODE
M
PIN CODE
M
PIN CODE
O
Only 1 User, Automatically deleted after use
Langu
-age
Setting
Language Change
OR
OR
OR
OR
OR
Delete
Delete all credentials
PIN CODE
M
PIN CODE
M
PIN CODE
M
Registr
-ation
Bluetooth Setting (Yale Access App)
PIN CODE
M
Delete
Registr
-ation
Remote Controller
OR
OR
PIN CODE
M
Up to 5 Users
UN
UN
Button
SET
Delete
Registr
-ation
Home Network Controller
OR
OR
PIN CODE
Mroller
Cont
PIN CODE
M
PIN CODE
M
Korean
Chinese
English
Taiwanese
8times
Set up a new device in the app
14 (Registration process)
1
High
Low
Mute
Volume Control
PIN CODE
M
OR
OR
OR
Disable
Enable
Automatic Lock
PIN CODE
M
Continue / Complete
Enable External Forced Lock : Fingerprint
Scan with registered fingerprint and hold the fingerprint area
until you hear 3 beep sounds.
Disable External Forced Lock
When the door is unlocked from outside based upon proper
authentication, the External forced lock will be released.
Palm touch Enter the
User PIN Code
Enter the
button for 5 Sec.
Enable External Forced Lock : User Code
※If you try to open a door with the manual thumb turn knob from inside when the Outside Forced Lock is set,
the alarm goes off.
※If the Inside Forced Lock is set, any attempt to open a door from outside whether it’s be a Fingerprint or
code won’t work.
Press Open/Close button
for 3 seconds until
you hear “pik” beep.
Method 1 :
Press Open/Close
button for 3 seconds
until you hear
“pik” beep.
Method 2 :
Turn manual
thumb turn knob.
Setting
‘ 3 ’
Seconds
Release
‘ 3 ’
Seconds
Turn it
OR
OR
ISL-1857-00-046
PLEASE READ INSTRUCTIONS BEFORE USE.
The functions and design of this product can be changed
without prior notice for performance and quality improvement.
Packaging of this product can be recycled.
User Slot Number should be 2 digits.
like ‘01’ … ‘99’ and ‘00’: Location of 100th user slot must be assigned "00" instead of "100".
※
22. Code Chart
Duplicate if necessary
PIN Code Management(Up to 100 Users.)
Do not install the digital door
lock in an outdoor environment.
24. Important notes
Do not attempt to disassemble
the digital door lock by yourself.
Do not spray water directly
or wipe with chemicals such as
benzene, gasoline or alcohol.
Do not use force with a tool
onto the product.
When using, remember that
someone else can see the
password.
Make sure the door is closed
properly when going out.
25. Safety and Warning
※Voice guidance :
Voice guidance features assist in easy navigation through various features.
※All registered passwords and other credentials will be deleted when mode is changed.
※Please install(register) the network module when you want to use a remote control or home network.
Part of ASSA ABLOY
You must replace all 4 batteries in the following cases:
* The Low Battery LED on keypad flickers red.
* When low battery notification message is played.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE
OF USED BATTERIES ACCORDING TO THE NATIONAL CODE OR RECYCLING PROGRAM.
Palm touch Palm touchEnter the user code
and fake code
Enter the Fake Code
and User code
OR
Enable External Forced Lock : RFID Key Tag
Contact RFID key tag on [RFID key tag reader] for 5 sec. until you
hear 3 beeps.
※In case of discharged batteries, please use 9V battery to supply power
Palm
touch
OR OR
Contact 9V
battery
Enter the User Code
and Plam touch
Contact
RFID Key Tag
Scan
fingerprint
Delete
OR
Registr
-ation
RFID Key Tag
UN
OR
UN
PIN CODE
M
Up to 100 Users