Chapter Title Page
1 INTRODUCTION ...............................................................1-1
1.1 Intended purpose of the ICC 200 ................................................ 1-1
1.2 Explanation of the safety instructions ......................................... 1-1
2 INITIALOPERATION.........................................................2-1
3 RISKSAND SAFETY
OF HIGH-FREQUENCY SURGERY..................................3-1
3.1 Unintentional thermal tissue damage .......................................... 3-1
3.1.1 - due to HF leakage currents ....................................................... 3-1
3.1.2 - due to unintentional activation of an HF generator .................. 3-2
3.1.3 - due to inappropriate application ............................................... 3-3
3.1.4 - due to inappropriate or nonapplication of
the neutral electrode .................................................................... 3-3
3.1.5 - due to unsuitable and/or faulty accessories............................... 3-4
3.1.6 - due to inattentiveness................................................................ 3-5
3.1.7 - due to an output error................................................................ 3-5
3.1.8 - due to the ignition of flammable liquids,
gases and/or vapors ..................................................................... 3-5
3.1.9 Unintentional burns due to hot electrodes................................... 3-6
3.2 Electric shock .............................................................................. 3-6
3.3 Stimulation of nerves and muscles .............................................. 3-6
3.4 Cardiac pacemaker ...................................................................... 3-7
3.5 Danger of explosion .................................................................... 3-7
3.6 Interference with other electronic equipment ............................. 3-7
3.7 Portable and mobile communication equipment HF .................. 3-7
4 DESCRIPTION OF THE HIGH-FREQUENCY
SURGICAL UNIT ...............................................................4-1
4.1 General description ..................................................................... 4-1
4.2 Description of the controls .......................................................... 4-3
1 Power switch .......................................................................................... 4-3
2 AUTO CUT function field ..................................................................... 4-4
3 AUTO COAG function field .................................................................. 4-5
4 Connecting socket for neutral electrodes ............................................... 4-6
5 Connecting socket for monopolar cutting or coagulation instruments ... 4-6
6 Connecting socket for bipolar coagulation instruments......................... 4-7
7 Safety field ............................................................................................. 4-7
8 Connecting socket for a dual-pedal footswitch...................................... 4-7
9 Terminal for potential equalization ........................................................ 4-7
10 Volume of the acoustic signal ................................................................ 4-7
11 Loudspeaker for the acoustic signals ..................................................... 4-7
12 Power connection ................................................................................... 4-7
13 Power fuses ............................................................................................ 4-7
4.3 Description of the safety features ........................................................... 4-8
5 TECHNICALDATA, SIGNALS, DIAGRAMS .....................5-1
5.1 Technical data.............................................................................. 5-1
5.2 Visual and acoustic signals.......................................................... 5-4
5.3 Diagrams ..................................................................................... 5-5