J.P. SELECTA, s.a. Cod. 80131 Rev 0 06/04/01 J.P. SELECTA, s.a. Cod. 80131 Rev 0 06/04/01 J.P. SELECTA, s.a. Cod. 80131 Rev 0 06/04/01
Tel.:93 770 08 77 Fax.: 93 770 23 62 e-mail: [email protected] Tel.:93 770 08 77 Fax.: 93 770 23 62 e-mail: [email protected] Tel.:93 770 08 77 Fax.: 93 770 23 62 e-mail: [email protected]
J.P. SELECTA, s.a.u
MECHERO / BURNER
J-3000
Código / Code:
1001134
RESOLUCIÓN DE PROBLEMAS
PARÁMETROS TÉCNICOS
J.P. SELECTA, s.a.u
Autovía A2 Km 585.1
08630 ABRERA (Barcelona)
SPAIN
Tel.:93 770 08 77
Fax.: 93 770 23 62
e-mail: [email protected]
Nº Problema Causa Solución
1 Sin llama
El gas se ha salido o no hay
suciente
Rellénelo
No hay llama una vez rellenado Espere 10 minutos o ajuste el
interruptor si fuera necesario
El nivel ajustable está demasiado
cerca del AMARILLO
Ajuste la palanca a AZUL
El tubo pierde Sustituya el accesorio
2 Llama demasiado larga Hay mucho gas Gire la tecla "-" hasta la
posición normal
3
Llama demasiado corta Hay poco gas Gire la tecla "+" hasta la
posición normal
Presión del aire demasiado baja o el
gas se ha volatilizado
Caliéntelo con las manos
No hay suciente gas en el tanque Rellénelo
4
Llama alargada y
redondeada
Accesorio bloqueado Sustituya el accesorio
Ajustar palanca a AMARILLO La palanca ajustable está
demasiado cerca de AZUL
Este mechero solo puede ser reparado por un servicio técnico
Tamaño producto base: 141,5x67x69
Peso bruto 323,6kg
Aplicar a presión de gas 0.36x0.42Mpa
Tiempo combustión 40-50 min
Temperatura de llama 1300ºC
Cambio de llama La llama mínima es de
20mm, la máxima de
55mm, bajo los 22ºC de la
temperatura ambiente
Capacidad tanque gas 8.5g
J.P. SELECTA, s.a.u. Cod. 80353 Rev 0 Set/2017 J.P. SELECTA, s.a.u. Cod. 80353 Rev 0 Set/2017
Tel.: 93 7700877 Fax: 93 7702362 e-mail:[email protected] Tel.: 93 7700877 Fax: 93 7702362 e-mail:[email protected] Tel.: 93 7700877 Fax: 93 7702362 e-mail:[email protected]
J.P. SELECTA, s.a.u. Cod. 80353 Rev 0 Set/2017
FUNCIONAMIENTO:
ENCENDIDO (Fig.1)
La palanca ajustable debe estar levantada. Pulse el
interrutor para encender. Cuando deje de pulsar, se
apagará.
SUSTITUCIÓN DE LA BATERIA (Fig.2)
Especicaciones de la batería LR6: 5 1.5V
Tal y como se muestra en la imagen, abra la tapa, sus-
tituya la batería según la posición original, y encienda
el mechero.
Nota: Tenga cuidado de no invertir la polaridad.
AJUSTE DE LA LLAMA (Fig.3)
Cuando la llama esté encendida, necesitará ajustarla:
AZUL cuando necesite una llama más larga y AMA-
RILLO con una llama más corta.
TAMAÑO DEL AJUSTE
Este mechero puede ajustarse según los requeri-
mientos de las diferentes situaciones de los trabajos
o del fuego.
"+" o "-" denotan el tamaño de la llama. Si la llama es
demasiado grande, puede ajustarse sin que sea me-
nor a 15mm o la llama se apagará automáticamente.
BLOQUEO DEL MECHERO (Fig.4)
Desbloquear el mechero (OFF) para su utilización.
Una vez nalizada su utilización diaria, bloquear de
nuevo el encendido (LOCK). Por seguridad comprobar
que el seguro esté bloqueado.
ADVERTENCIAS:
- La longitud de la llama no debe ser demasiado grande.
- El mechero no puede estar mucho tiempo encendido y no debe
colocarse boca abajo.
- Espere 10 minutos después de rellenarlo y no lo agite con fuerza.
- Mantener alejado de llamas, de la luz solar o de temperaturas
superiores a 40º.
- Mantener fuera del alcance de los niños.
- Mantener alejado de la cara y de la ropa.
LLENADO DEL GAS (Fig.6)
Girar el mechero y colocar la válvula del recargador en
la entrada del gas. Presionar durante unos segundos.
Mantener alejado del fuego durante el llenado y tampoco
encienda el mechero.
ADVERTENCIAS:
Este producto dispone de la función de auto-llenado. El gas se
podría derramar al llegar a la cantidad segura. Por favor, deje de
rellenarlo o el mechero podría funcionar de forma correcta e incluso
podría causar daños.
OPERATION:
HOW TO IGNITE (Fig.1)
The adjustable lever must be raised. Press the switch
to turn on. When you stop pressing, it will turn off.
REPLACING THE BATTERY (Fig.2)
Battery Specications LR6: 5 1.5V
As shown in the picture, open the cover, replace the
battery according to the original position, and turn on
the burner.
Note: Be careful not to reverse the polarity.
ADJUSTING THE FLAME (Fig.3)
When the ame is on, you will need to adjust it: BLUE
when you need a longer ame and YELLOW with a
shorter ame.
ADJUSTMENT SIZE
This lighter can be adjusted according to the require-
ments of different work situations or re.
"+" or "-" denote the size of the ame. If the ame is
too large, it can be adjusted without being less than
15mm or the ame will turn off automatically.
HOW TO LOCK (Fig.4)
Unlock the burner (OFF) for use. Once its daily use is
over, lock the ignition (LOCK) again. For safety check
that the lock is locked.
WARNINGS:
- The length of the ame should not be too large.
- The burner may not be on for a long time and should not be turned
upside down.
- Wait 10 minutes after relling and do not shake it vigorously.
- Keep away from ames, sunlight or temperatures above 40°C.
- Keep out of the reach of children.
- Keep away from face and clothing.
FILLING THE GAS (Fig.6)
Put the burner upside down and place the recharger
valve in the gas inlet. Press for a few seconds. Keep
away from re during lling and do not light the burner.
WARNINGS:
This product has a self-lling function. The gas could be spilled out
when reaching the safe quantity. Please stop relling it or the burner
could not work properly and could even cause damages.

This manual suits for next models

1

Other J.P. SELECTA Laboratory Equipment manuals

J.P. SELECTA PRO-NITRO A User manual

J.P. SELECTA

J.P. SELECTA PRO-NITRO A User manual

J.P. SELECTA CENTRO-8 BL User manual

J.P. SELECTA

J.P. SELECTA CENTRO-8 BL User manual

J.P. SELECTA MICRO 8 User manual

J.P. SELECTA

J.P. SELECTA MICRO 8 User manual

J.P. SELECTA AUTESTER ST DRY PV-B print 18L User manual

J.P. SELECTA

J.P. SELECTA AUTESTER ST DRY PV-B print 18L User manual

J.P. SELECTA Vortex Vib User manual

J.P. SELECTA

J.P. SELECTA Vortex Vib User manual

J.P. SELECTA PRECISDIG 6001120 User manual

J.P. SELECTA

J.P. SELECTA PRECISDIG 6001120 User manual

J.P. SELECTA Digitronic-TFT 2005163 User manual

J.P. SELECTA

J.P. SELECTA Digitronic-TFT 2005163 User manual

J.P. SELECTA RE-605 User manual

J.P. SELECTA

J.P. SELECTA RE-605 User manual

J.P. SELECTA UNIVEBA 110C User manual

J.P. SELECTA

J.P. SELECTA UNIVEBA 110C User manual

J.P. SELECTA CONTERM 19L User manual

J.P. SELECTA

J.P. SELECTA CONTERM 19L User manual

J.P. SELECTA COMBIPLAC 3000156 User manual

J.P. SELECTA

J.P. SELECTA COMBIPLAC 3000156 User manual

J.P. SELECTA RS 3001-V User manual

J.P. SELECTA

J.P. SELECTA RS 3001-V User manual

J.P. SELECTA HPC PL-3 User manual

J.P. SELECTA

J.P. SELECTA HPC PL-3 User manual

J.P. SELECTA UV 2005 User manual

J.P. SELECTA

J.P. SELECTA UV 2005 User manual

J.P. SELECTA DIGITAL-S User manual

J.P. SELECTA

J.P. SELECTA DIGITAL-S User manual

J.P. SELECTA PRECISDIG 6001195 User manual

J.P. SELECTA

J.P. SELECTA PRECISDIG 6001195 User manual

J.P. SELECTA DRYGLASS User manual

J.P. SELECTA

J.P. SELECTA DRYGLASS User manual

J.P. SELECTA APL-54 User manual

J.P. SELECTA

J.P. SELECTA APL-54 User manual

J.P. SELECTA 7001490 User manual

J.P. SELECTA

J.P. SELECTA 7001490 User manual

J.P. SELECTA DE-1626 User manual

J.P. SELECTA

J.P. SELECTA DE-1626 User manual

J.P. SELECTA PRECISBIG 6001240 User manual

J.P. SELECTA

J.P. SELECTA PRECISBIG 6001240 User manual

J.P. SELECTA SE-100 User manual

J.P. SELECTA

J.P. SELECTA SE-100 User manual

J.P. SELECTA UNITRONIC-ORBITAL User manual

J.P. SELECTA

J.P. SELECTA UNITRONIC-ORBITAL User manual

J.P. SELECTA FRIGITERM TFT-10 User manual

J.P. SELECTA

J.P. SELECTA FRIGITERM TFT-10 User manual

Popular Laboratory Equipment manuals by other brands

Zeiss Axiocam 208 color instruction manual

Zeiss

Zeiss Axiocam 208 color instruction manual

MELAG Vacuklav 41 B+ Evolution user manual

MELAG

MELAG Vacuklav 41 B+ Evolution user manual

Beckman Coulter LH 780 instructions

Beckman Coulter

Beckman Coulter LH 780 instructions

Transition Networks SI-IES-1200-LRT user manual

Transition Networks

Transition Networks SI-IES-1200-LRT user manual

Grant Optima T100 operating manual

Grant

Grant Optima T100 operating manual

IKA WERKE IKAMAG RET control-visc operating instructions

IKA

IKA WERKE IKAMAG RET control-visc operating instructions

Merck Milli-Q EQ 7008 user manual

Merck

Merck Milli-Q EQ 7008 user manual

CEM EasyPrep Series manual

CEM

CEM EasyPrep Series manual

Huvitz Excelon CAB-4000 Operator's manual

Huvitz

Huvitz Excelon CAB-4000 Operator's manual

Altronix NetWay1 installation guide

Altronix

Altronix NetWay1 installation guide

Evertree Liva EBS Series user manual

Evertree

Evertree Liva EBS Series user manual

Ibi QS-710 Operator's manual

Ibi

Ibi QS-710 Operator's manual

Labnet Spectrafuge 6C user manual

Labnet

Labnet Spectrafuge 6C user manual

Thermo Scientific 5030i SHARP instruction manual

Thermo Scientific

Thermo Scientific 5030i SHARP instruction manual

MOGlabs MWM manual

MOGlabs

MOGlabs MWM manual

Metrohm 940 Professional IC Vario Series manual

Metrohm

Metrohm 940 Professional IC Vario Series manual

THORLABS FSAC user guide

THORLABS

THORLABS FSAC user guide

Thermo Scientific RC 12BP Plus instruction manual

Thermo Scientific

Thermo Scientific RC 12BP Plus instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.