manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PNI
  6. •
  7. Security System
  8. •
  9. PNI PG100 User manual

PNI PG100 User manual

Other PNI Security System manuals

PNI SafeHouse HS007LR User manual

PNI

PNI SafeHouse HS007LR User manual

PNI House AHD1250 User manual

PNI

PNI House AHD1250 User manual

PNI SAFE HOUSE PG600 User manual

PNI

PNI SAFE HOUSE PG600 User manual

PNI SmartHome SM400 User manual

PNI

PNI SmartHome SM400 User manual

PNI HOUSE WiFi650 User manual

PNI

PNI HOUSE WiFi650 User manual

PNI SafeHouse HS008 User manual

PNI

PNI SafeHouse HS008 User manual

PNI S004 User manual

PNI

PNI S004 User manual

PNI PG600LR User manual

PNI

PNI PG600LR User manual

PNI SafeHome PT700 User manual

PNI

PNI SafeHome PT700 User manual

PNI SafeHouse HS600 User manual

PNI

PNI SafeHouse HS600 User manual

PNI SafeHouse HS007 User manual

PNI

PNI SafeHouse HS007 User manual

PNI A014 User manual

PNI

PNI A014 User manual

PNI SafeHouse HS650 User manual

PNI

PNI SafeHouse HS650 User manual

PNI House WiFi550 User manual

PNI

PNI House WiFi550 User manual

PNI House WiFi550 User manual

PNI

PNI House WiFi550 User manual

PNI SafeHouse HS007LR User manual

PNI

PNI SafeHouse HS007LR User manual

PNI House PTZ1350 User manual

PNI

PNI House PTZ1350 User manual

PNI IP590 User manual

PNI

PNI IP590 User manual

PNI House WiFi 400 User manual

PNI

PNI House WiFi 400 User manual

PNI HOUSE IP516 User manual

PNI

PNI HOUSE IP516 User manual

PNI HOUSE PTZ1300 User manual

PNI

PNI HOUSE PTZ1300 User manual

PNI IPMAX POE FIVE User manual

PNI

PNI IPMAX POE FIVE User manual

PNI PG2710 User manual

PNI

PNI PG2710 User manual

PNI SafeHouse HS550 User manual

PNI

PNI SafeHouse HS550 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Security GSM Alarm System
USER MANUAL
4 wired and 6 wireless defense zones;
Can preset and store 6 voice phones and 3 message phones;
Remote two-way intercom;
Telephone (mobile phone) remote control programming;
SMS remote control preset & arm/disarm the main panel;
SMS alarm content can be changed;
10 groups of timely arm and disarm;
10 groups reply to timely control the home appliances open or close;
Can connect wireless siren(Option)
10-second automatic message recording;
Built-in intelligent English message;
Alarm locking memory and information clear for easy checking;
One-key-control function: Out Arm, Home Arm, Remote Arm;
Wireless intelligent learning encoding and comply additional accessories;
Arm, disarm, monitor and intercom by remote calling the alarm unit;
Real-time, delay, 24 hours, bypass defense zones programming function;
Built in NI-HI rechargeable battery is available to provide power supply nearly 5hours automatically after
power off;
AC and DC dual use are available for 24-hours-a-day normal guard;
Main unit anti-tamper and low-voltage detecting function.
1 System Introduction
Wireless GSM intelligent anti-theft electronic alarm system is an innovative wireless mobile intelligent
warner integrating GSM digital signal processing techniques and imported STC microprocessor, and a variety
of technologies including digital voice announcer, English SMS, learning code, etc.
In addition, this alarm system is highly automatic, giving automatic voice or SMS alert in the event of
emergency without intensive manual settings required. Features of stability, reliability, safety, and humanizing
control enable it to be widely used for alert in shops, convenience stores, offices, villa as well as residential
communities
Gate magnetism installation
Use the random equipped double-side tape to stick a magnetic stripe on the door and affix the gate magnetic
emission box on the doorframe. Pay attention to put the magnetic strip close to the side with indicator lights of
the emission box during installation, assuring proper alignment and the smaller distance the better.
Infrared detector installation
The principle of infrared detectors is to sense people’s movement through sensing infrared signals generated
by bodies and the detection range is usually 5-12 meters. Infrared sensor should be installed about 2.2
meters away from ground. Aim straight at the detection ranges. Moreover, the infrared detector can be only
installed in the room, without facing the sunshine, windows and other places where temperature is easy to
change, because the installed location may influence the detection range and accuracy.
2 Technical Parameter
3 Factory default
Programming password: 8888 Remote Control: Enabled
Operation Password: 0000 Ringing Times: Once
Siren Duration: 300 seconds Timing Setting: Disable
Wired defence zone Disable Delay Setting Disable
Power Output Out Zone model real-time
Input Voltage: DC9V~12V
Standby Current: <55mA
Alarm Current: <450mA
Wireless Frequency: 315/433.92MHz, 2262/4.7MΩ
GSM Frequency: 900/1800/1900MHz
Backup Battery: NI-HIAAA*6 DC7.4V
Alarm Loudness: 110dB
Out DC12V,1A
4 Installation
Main Unit Installation
Be careful to keep it away from large metal objects or household appliances which may cause high frequency
interference, as well as barriers such as reinforced concrete walls and fire doors.
SIM Card Installation
Step 1: Push out the SIM card socket as the open direction.
Step 2: Fit the GSM card into the card socket properly.
Step 3: Push the card socket as close direction until it is fit firmly.
5 Main Unit Settings
Prompt Message
Function Operation Instructions Notes
Short “beep” Key-press prompt
Beep Long “beep” Confirm prompt
Four short “beep” Error prompt
“Beep” continue SIM card is not fit or power on for the first time
Defence zone
indicator Always on Alarm lock
Flickering Disarm status, this defence zone is triggered
Arm indicator Fast flickering Arm status
Slow flickering Settings status/At home status
Always on Alarming status
GSM
indicator Always on GSM failure
Flickering Weak GSM signal or no signal
Slow flickering GSM normal
Power-on for the First Time
Following the method of installation, install the SIM card of main unit, make wired connection and fit the
GSM antenna properly in order. Then plug the power adapter. At that time, all the indicators of 6 defence
zones and 2 function indicators on the main unit flicker once and the buzzer emits a long “beep”; then the
main unit starts to search the GSM network with “beep” continuing(The time to search network is about 8
seconds to 55 seconds). Until the network is normal, “beep” stops, the power indicator is always on and the
main unit is in the status of disarm.
At last, slide the switch of backup battery to [ON] with nippers or a small screwdriver.
Factory Reset
First switch off the backup battery and cut off the power supply, press and hold the button [Set] on the top
of unit,then turn on the power adapter; 3 seconds later, the buzzer emits a long “beep” and all the LED
indicators go on but go off instantly; at last you can release the button. That's mean all its settings cleared and
return to its factory settings successfully.
Voice Record
In the status of disarm, press [Set] for 3 times, the main unit emits a long “beep”, and [Arm] indicator
flickers (once a second), then recording starts: recording at 30cm away from the main unit, with standard of
moderate voice; 10 seconds later, recording stops automatically and [Arm] indicator goes out.
Enter Setting
In the status of disarm, press and hold [Set]; 3 seconds later, the main unit emits a long “beep”, [Arm]
indicator flickers and the main unit enters the setting status.
In the status of settings, as long as keeping the status of setting ([Arm] indicator flickers), you can program
different settings repeatedly. During setting, however, if you stop setting operation for over 30 seconds, the
main unit will exit from setting mode automatically and return to the status of disarm.
Exit Setting
After setting is finished, all the indicators of the defence zones is off but only [Arm] indicator flickers; press
[Set] for 3 seconds,the main unit exits from setting. [Arm] indicator goes off, the main unit returns to the status
of disarm.
Code Pairing by Remote Control
Code Pairing of Remote Control
In the status of disarm, enter settings and press [Set] once again, the main unit emits a short “beep” and
all the indicators of the defence zone are always on, which indicate that the unit enters remote control code
pairing status; take a remote control required for code pairing and press any key on it to emit a wireless signal
to main unit; after the main unit receive the signal, it emit a beep and all the indicators of defence zone go out,
which indicate the remote control succeeds in code pairing.
Cautions: the main unit can provide code pairing for at most 8 remote controls. Code pairing for all remote
controls is the same.
Delete Remote Control
In the status of disarm, enter settings and press [Set] once again, the main unit emits a long “beep” and all
the indicators of the defence zone are always on, and then it enters remote control code pairing status; press
and hold [Set] for 3 seconds, the main unit emits a long “beep” and all the indicators of the defence zone go
out. Remote control paired successfully.
Cautions: when deleting remote control, all the remote controls would be deleted.
Code Pairing of defence zone
Code Pairing of defence zone
In the status of disarm, enter settings, press [Set] once again to enter the remote control code pairing
status; press [Set] once again and the indicator of defence zone 1 goes on; then, take a sensor required for
code pairing and trigger an alarm to emit a wireless signal to the main unit; after the main unit receives this
signal, it emits a long “beep” and the indicator of defence zone 1 goes out, which indicate code pairing in
defence zone 1 is paired successfully.
Cautions: in the status of disarm, enter settings, skip code pairing of remote control and continue to press
[Set], and then the indicators of the defence zone go on one by one; select a defence zone to perform code
pairing and the indicator of this defence zone goes on. Repeat the code pairing operation in the paragraph
above for all other defence zone.
Code pairing for the defence zone on main unit can be overwrote automatically, which means only the last
code pairing is valid. Therefore, code pairing can only be performed for one sensor in a defence zone; in case
the number of sensors required is more than that of the defence zone, you can edit the address code and
digital code of the sensors of same type to be the same exactly. By doing so, you just need to perform code
pairing for one sensor, and then other sensors with the same codes can work normally. In alarm, it will
indicate the same defence zone.
Delete Code Pairing
In the status of disarm, enter settings and skip code pairing of the remote control; press [Set] once again,
then the indicator for defence zone 1 goes on; then, long press [Set], three seconds later the main unit emits
a long “beep”, and the indicator of defence zone 1 goes out. Code pairing for defence zone 1 is deleted
successfully.
Wireless keyboard
Into the set, jump to zone 6 yards again click on the [set], all the zone lights, began to learn the wireless
keyboard, remote control with learning to learn.
6 Remote Control Programming
All the programming of the main unit are completed by key operations on a phone or send SMS
commands, which shall dial GSM card number of main unit first.
In the status of disarm, after GSM network is checked to be normal, dial the SIM card number by mobile
phone (or fixed phone), the main unit will answer automatically and give a voice prompt “Please enter the
password”; then you can enter the correct programming password (factory default: 8888); after that, the main
unit emits a long “beep”, and the [Arm] indicator flickers, indicating that the main unit enters remote control
programming.
Function Instructions
Function Operation Instructions Notes
Enter Programming Enter [password] Long “beep”
Exit Settings Hang up directly Short “Beep”
Change Password [*]+1+ [New operating Password]
+[ New Programming Password]
+[*]
Factory default: 0000
Factory default: 8888
Set Phone # + (1~6) +phone numbe + # 1-6 group voice calls
Message Receiving Phone
Number # + (7-9) +phone numbe + # SMS phone
Delete Phone Number # +(1~9)+#
Siren set # +0+A+B+C+ #
Setting time *+2+AABB+* “AA”Hour, “BB”Minute
Timer Arming *+3+AABB+C+* “C”:0,Disable
Timer disarm *+4+AABB+C+* “C”:1-9, Enabled
Timer switch *+5+AABB+C+1/0+*
Delay Setting *+6+A+B+C*
Wired zones set *+7+ABCD(1/0)+*
defence zone Programming *+8+A+B+C+*
Alarm message *+9+A+(0-9)+*
Output Settings *+0+(0-9)+1/0+*
SMS Instructions
Function Operation Instructions Notes
Custom SMS [Programming password] +[1-9] +
[content of the message]
Function settings [Programming password]
+[Instruction]
Arming [Programming password] +[“SF”] For example:8888SF
Disarm [Programming password] +[“CF”]
Intelligent defenses [Programming password] +[“BF”]
Check status [Programming password]
+[“STATUS”]
Open the output [Programming password] +[“ON”]
Close Output [Programming password] +[“OFF”]
SMS query [Programming password] +[1-9]
Query time [Programming password]
+[“TIME”]
By phone or wireless keyboard or SMS, enter the following command operation alarm system
Change Password
*1×××× ×××× *
Illustration: “X” indicates the new password; for example, change the factory default (0000) of operating
password into the new password: 1234. change the factory default (8888) of programming password into the
new password: 8765.
Input:*112348765*
SMS Command: 8888*112348765*
Cautions: the operation password and the programming password can not be set to the same number.
Phone Setting
Voice Call
When it is set to alert through voice call, the main unit can send warning voice message to 6 phone
numbers, (for example: defence zone 5, balcony alarm, this is……) . Telephone number 1-6.
Message Receiving Phone Number
When it is set to alert through message, the main unit will send alarm SMS to three phone numbers, (for
example: defence zone 5, balcony alarm). Telephone number 7-9.
Phone Number Settings:
# 1 ××…×× #
# 2 ××…×× #
…
# 8 ××…×× #
# 9 ××…×× #
Delete Phone Number:
# 1 #
# 2 #
…
# 9 #
Illustration: “X” indicates the set voice alarm-receiving phone number; set 0755-12345678 to be the second
voice call number.
Input:#2075512345678#
SMS Command: 8888#2075512345678#
Illustration: “X” indicates the set message-receiving phone number; set 13812345678 to be the first
message-receiving phone number.
Input:#713812345678#
SMS Command: 8888#713812345678#
Delete the third group of voice call number.
Input:#3#
SMS Command: 888853#
defence zone Programming
*8ABC*
Notes: “A” indicates the number of defence zone; “B” indicates the type of defence zone; “C” indicates if the
siren sounds.
A: Number of defence zone: [1~6] corresponds to defence zone 1 to defence zone 6 respectively. [7~0](0 as
10)Correspond to the cable zone L1-L4.
B: Type of defence zone: [0] Delete zone, [1] real-time, [2] Intelligent defense area,[3] Emergency zone [4]
multi-checked defense area, [5] delay-alarm defense area,[6] repeat triggered defense area
C: Type of siren: [0] sound-off, [1] sound-on
Illustration: set the defence zone 1 to Emergency zone ,alarm sound.
Input:*8131*
SMS Command: 8888*8131*
Intelligent defense area:After selecting an area as intelligent defense one, the defense area is not effective
(it is still effective under the normal defense area), which is suitable when hosts at home, because indoor
infrared alarm function is canceled, while the gate magnetisms on the door and window are still in a state of
monitoring.
Multi-checked defense area: Under the situation of defense or intelligent defense, if two or more detectors
that set up multi-checked are all triggered within 30 seconds, the main engine will give an alarm. Therefore,
based on this pattern, none of the infrared detectors will misinform the events.
Delay alarm defense area: When the defense area is triggered and need alarm, the main engine can delay
the alarm (the concrete delay time is determined by the “Setting up alarm delay”); moreover, the warning
behavior can be canceled during delayed time.
Repeat triggered defense areas: When the detector is triggered once, the system will not alarm
immediately. Only when it is triggered again within 5-30 seconds after the first trigger, the system will alarm.
■
Operating Siren
#0ABC#
Notes: “A” indicates if the siren emits a prompt when enabling and disarm by remote control: [0] sound on, [1]
sound-off.
“B” Alarm ringing time, "B" host after the alarm sounded the alarm time,Value between 0-9 minutes,0
indicates that the host is not ringing.
“C "alarm sound in the size of, Value between 0-9, 0 is not ring the alarm, 1-9 that sound an alarm.
Illustration: Alarm will sound when the remote control, Siren sound five minutes off, Siren sound level 9
Input:#0159#
SMS Command: 8888#0159#
■
Power Output Set
*0AB*
Notes: “A” 0-9 stands for the control state of 12V power supply and selections as below:
0=not output 12V.1=output 12V in the state of Disarm, while close output under other states.
2 or 3=output 12V in the state of Arming,
4 or 5=output 12V in the state of “Intelligent defenses”,
6 or 7= output 12V in the state of Arming or “Intelligent defenses”,
8=output 12V in the state of alarming.
9=keep outputting 12V.
B” Alarm ringing time, "B" host after the alarm sounded the alarm time,Value between 0-9 minutes,0
indicates that the host is not ringing.
■Clock Setting
*2AA BB *
“AA” indicates: the 2 digits of the present hour.
“BB”indicates: the 2 digits of the present minute.
For example: set the time as 19:18
Operating method: *21918*
SMS Command: 8888*21918*
■Timing Setting
1. Timely Arm
*3AA BB C*
“AA”indicates: the hour of the setting time
“BB”indicates: the minute of the setting time
“C” indicates: Storage location and unset,1-5 group is periodically set,6-9 group is a temporary set,0 is
cancel all settings
For example:Auto arm every day 17:40,Stored in the Group 1
Operating method:*317401*
SMS Command: 8888*317401
2. Timely Disarm
*4AA BB C*
“AA”indicates: the hour of the setting time
“BB” indicates: the minute of the setting time
“C” indicates: Storage location and unset,1-5 group is periodically set,6-9 group is a temporary set,0 is
cancel all settings
For example: 8:00 auto disarm, disarm canceled after this setting,Stored in the Group 9
Operating method:*408009*
SMS Command: 8888*408009*
3. Timing switch power supply
*5AA BB CD*
“AA” indicates: the hour of the setting time
“BB” indicates: the minute of the setting time
“C” indicates: Storage location and unset,1-5 group is periodically set,6-9 group is a temporary set,0 is
cancel all settings
“D” indicates: Power output or close output,1= Power output,0=Close output
For example: Power output every day 12:30,Stored in the Group 5
Operating method:*5123051*
SMS Command: 8888*5123051*
For example: 13:00 Close output, turn off the output to cancel the setting after,Stored in the Group 9
Operating method:*5130050*
SMS Command: 8888*5130050*
■Telephone set rings, fortified delay and alarm delay setting
*6ABC*
"A" call to set the host, the host receive ring many times, value 0-9,0 not answer the phone. “0” means no
remote setup.
"B" Arming delay, Values between 0-9,0 to cancel the delay. Each value is equal to 10 seconds
"C" alarm delay, Values between 0-9,0 to cancel the delay. Each value is equal to 10 seconds
For example: Ring nine times to answer, arming delay 50 seconds, Delay zone alarm delay time of 10
seconds
Operating method:*6951*
SMS Command: 8888*6951*
■Set up wired defense area
*7ABCD*
ABCD sequence corresponding to the cable zone L1, L2, L3, L4, the value is "1" or "0", "1" refers to the
default wired normally open zone, "0" refers to the default zone wired normally closed.
Close wired zones*7*
■SMS related operations