Translation of the Original Operating Manual
V-BIO Combi / V-BIO Combi2D Biogas Equipment
2.2.4 Intended use
The solids dispenser V-Mix Combi / Combi 2D is intended exclusively for collecting and dispensing silage
and other renewable raw materials and may only be operated in combination with the designated storage
container.
The specific weight of those materials may not exceed 500 kg per m³.
The solids dispenser must be set up outside of potentially explosive areas (EX Zones).
The incomplete Solids dispenser machine must not be put into operation until it has been incorporated
into the overall system and the CE conformity of the overall system has been established.
Any other use above and beyond this will be regarded as misuse and is prohibited. Bernard van
Lengerich Maschinenfabrik GmbH & Co. KG cannot be held liable for any damage resulting therefrom.
Intended use also comprises:
Use within the performance limits specified in the chapter 3 "Technical data".
Use as intended and described in the installation instructions and the operating manual.
Observing all information and regulations specified in the installation instructions and the operating
manual as well as all accompanying documents.
Adhering to the inspection and maintenance intervals that are mandatory or listed in the assembly
and operating manual including all accompanying documents.
Ensuring that all activities are performed by trained specialty personnel only.
Ensuring that all spare parts used comply with specifications.
Ensuring that no retrofitting or use of third-party accessories takes place without our consent.
2.2.5 Misuse
Misuse includes the following types of use in particular:
Use for products other than the ones specified in the order.
The use of products with altered product characteristics.
Conveying hard/solid materials such as rocks, metal objects, etc. that will result in damage to or
failure of the incomplete machine.
Operation, maintenance and repairs of the incomplete machine by individuals other than authorized
and trained personnel.
The operation of the solids dispenser unit without a valid CE mark on the overall system.
Operation inside an EX Zone.
Please observe the following for fault-free operation of the dispenser:
Make the substrate conveyable with a maximum stalk length of 100mm
Structure-free material -decomposed, messy, or wet solid manure. Make turkey manure or simi-
lar types of waste, grain strip waste, etc. without structure conveyable by adding structured ma-
terial, such as corn or grass silage, straw, etc.
Avoid foreign objects (stones, wood, bale twine, and nets).
Check the dosing augers repeatedly for wear and damage.
Check the auger blade continuously and re-sharpen or replace as necessary.
Observe the maximum fill weight and height for the dispenser . Loss of warranty.
Reduce the fill quantity when working with stiff materials (solid manure, long-straw grass silage,
etc.).