ACME Libre User manual


CONTENTS
1. Safety Instructions ......................................................................................... 2
2. Technical Specifications ................................................................................. 4
3 Control Panel .................................................................................................. 6
4. Color/Gobo and Lamp.................................................................................... 7
4.1 Color/Gobo .............................................................................................. 7
4.2 Light Source ............................................................................................. 8
4.3 Change The Lamp..................................................................................... 8
4.4 Lamp Replacement Warning .................................................................. 10
5. How To Set The Unit..................................................................................... 10
5.1 Main Function........................................................................................ 10
5.2 Home Position Adjustment .................................................................... 18
6. Control By Universal DMX Controller ........................................................... 21
6.1 DMX512 Connection.............................................................................. 21
6.2 Address Setting ...................................................................................... 22
6.3 DMX512 Configuration........................................................................... 22
7. Error Information......................................................................................... 30
8. Troubleshooting........................................................................................... 33
9. Fixture Cleaning........................................................................................... 34
1E

1. Safety Instructions
WARNING
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer will
not accept liability for any resulting defects or problems.
Unpack and check carefully that there is no transportation damage before using the unit.
This product is for indoor use only. Use only in a dry location.
DO install and operate by qualified operator.
DO NOT allow children to operate the fixture.
Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces.
Be sure that no ventilation slots are blocked, otherwise the unit will be overheated.
Before operating, ensure that the voltage and frequency of power supply match the power
requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
Minimum ambient temperature TA: 0℃. Maximum ambient temperature TA: 40℃.
DO NOT connect the device to any dimmer pack.
During initial start-up some smoke or smell may arise. This is a normal process and does not
necessarily mean that the device is defective, and it will decrease gradually within 15 minutes.
Make sure there are no flammable materials close to the unit while operating to avoid fire
hazard.
Examine the power wires carefully; replace them immediately if there is any damage.
Unit’s surface temperature may reach up to 90℃. DO NOT touch the housing bare-handed
during its operation.
Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut
Please read the instruction carefully which includes important information about
the installation, usage and maintenance.
2E

off the mains power immediately.
DO NOT operate in dirty or dusty environment, do clean fixtures regularly.
DO NOT touch any wire during operation as there might be a hazard of electric shock.
Avoid power wires together twist other cables.
The minimum distance between light output and the illuminated surface must be more than 12
meters.
Disconnect mains power before fuse/lamp replacement or servicing.
Replace fuse/lamp only with the same type.
In the event of serious operating problem, stop using the unit immediately.
Never turn on and off the unit time after time.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
DO NOT open the unit as there are no user serviceable parts inside.
Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance center if
needed.
Disconnect the mains power if the fixture is has not been used for a long time.
DO use the original packing materials before transporting it again.
Hot lamp explosion hazard. DO NOT open the unit within 15 minutes after switching off.
DO replace the bulb once it is damaged, deformed or life-expired.
DO NOT look directly at the light while the bulb is on.
Never touch bulb with bare fingers, as it is very hot after using.
DO NOT start on the unit without bulb enclosure or when housing is damaged.
Installation:
The fixture should be mounted via its Omega Quick Release Clamp bracket. Always ensure that the
unit is firmly fixed to avoid vibration and slipping while operating and make sure that the structure
to which you are attaching the unit is secure and is able to support a weight of 10 times of the
fixtures weight. Always use a safety cable that can hold 12 times of the weight of the fixture when
installing.
The equipment must be installed by professionals. It must be installed in a place where is out of the
reach of people and no one can pass by or under it.
3E

2. Technical Specifications
Power Voltage:
AC 100~240V, 50/60Hz
Power Consumption:
555W
Light Source:
PHILIPS MSD Platinum 18 R LL
Color Temperature:
8000K
Zoom Range:
Beam Mode: 3°~7°
Spot Mode: 5°~32°
Wash Mode: 18°~23°
Movement:
Pan: 540°
Tilt: 270°
Pan/Tilt Resolution: 16bit
Dimmer/Shutter:
Smooth dimming from 0-100%; outstanding strobe effect with variable speed
Color wheel:
1 color wheel with 14 colors plus white, and rainbow effect
Gobo wheel:
1 static gobo wheel with 17 gobos plus open
1 rotating gobo wheel with 12 gobos plus open
Control:
DMX Channel: 19/21 Channels
Protocols: DMX512, RDM
Firmware Upgrade via DMX link or USB disk
4E

Construction:
Display: LCD Color display
Date In/Out: 3-pin and 5-pin XLR
Power In/Out: Wire/Power Connector in/ out
Protection Rating: IP20
Features:
Linear motorized zoom
Motorized Focus
2 prisms: 8-facet prism+ 6-facet linear prism, rotatable in both directions and overlayable
Outstanding color macro effect
Independent frost effect
Integrated three features: beam, spot, and wash
Dimension/Weight:
435x344x607mm, 22.5kgs
17.1"x13.5"x23.9"in, 49.6lbs
5E

3 Control Panel
Wire Version:
POWERCON Version:
1. Display: To show the various menus and the selected function
2. Button:
MENU
To enter into move backward or leave the menu
UP
To go backward to move up in the menu
DOWN
To go forward to move down in the menu
ENTER
To perform the desired functions
3. BATTERY DISPLAY
4. DMX IN:
For DMX512 operation, use 3/5 XLR cable to link the unit and DMX controller
5. DMX OUT:
For DMX512 operation, use 3/5 XLR cable to link the next units
6E

6. POWER (POWERCON Version):
Use to connect to supply power
7. FUSE(T 10A):
Protect the unit from damage of over current
8. FIRMWARE UPGRADE:
To upgrade the unit firmware
9. POWER SWITCH:
Turn On/Off the power
10. POWER (Wire Version):
To connect to the mains supply
4. Color/Gobo and Lamp
4.1 Color/Gobo
DANGER!
Install the color wheel/gobo wheels with the device switched off only.
Unplug from mains before changing the color wheel/gobo wheels!
CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be
opened!
7E

4.2 Light Source
PHILIPS MSD Platinum 18 R LL
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful
to the eyes and skin. The high luminance of the arc can cause severe damage to the
retina if you take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX controller)
and let the unit run at least five minutes to cool down before switching off the mains
supply. Never handle the lamp or luminary when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do not
use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.
4.3 Change The Lamp
Attention: The entire light path and lens of the luminaire must be thoroughly cleaned before
changing the bulb.
In the Work Mode, the lamp life is 1500 hours; when the Work Mode and the Sleep Mode are used
alternately, the lamp life is between 1500 and 6000 hours according to the ratio of lamp use time; in
the Sleep Mode, the lamp life is 6000 hours. Do not use the bulb beyond its lifetime, otherwise it
may damage the luminaire. Check the Lamp Use Time regularly. When the lamp replacement
warning appears, we strongly recommend that you replace the bulb. After replacing the bulb, the
use hours of the bulb must be cleared and reset.
To replace the lamp:
1. Ensure that the fixture is detached from power and has cooled down completely. It is a good
idea to allow the fixture to run for 10 minutes after the lamp has been turned off, so that the
cooling fans have time to works.
2. Loosen the screws on the head of the fixture and open the fixture head covers.
8E

3. Loosen the screw that holds the lamp in place. Unplug the leads of the lamp and lift the lamp
out of its recess, disconnect the lamp and connect a new lamp that must be the same type with
the old one. And then place the new lamp into the lamp recess.
Finally reinstall the head cover, fastening it securely before reapplying power.
Warning:
The installing direction of lamp:
9E

4.4 Lamp Replacement Warning
When the lamp reaches 300 hours before its service time, the display will flash the message
“Replace Lamp Soon” for up to 5 minutes. During this period, the fixture will still work normally.
When the lamp reaches its service time, the display will flash the message “Replace Lamp Now”
for up to 10 minutes. After 10 minutes, the fixture will return to normal operation.
When the lamp is continuously used overtime, the display will flash the message “Lamp
Timeout Use, Replace Lamp Now” for up to 10 minutes. After 10 minutes, the fixture will return
to normal operation.
Attention: Damages caused by the failure to replace the bulb in time are not subject to warranty.
5. How To Set The Unit
5.1 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until
the required function is shown on the monitor. Select the function by the ENTER button. Use the
UP/DOWN button to choose the submenu, press the ENTER button to store and automatically
return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit menu mode.
The main functions are shown below:
10E

11E

DMX Settings
To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select
DMX Address, DMX Channel Mode, No DMX Status or View DMX Value.
DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the
address from 1to 494/492, press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
DMX Channel Mode
To select DMX Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to
select Mode1 (19) or Mode2 (21), press the ENTER button to store. Press the MENU button back to
the last menu or let the unit idle 30 seconds to exit menu mode.
No DMX Status
To select No DMX Status, press the ENTER button to confirm. Use the UP/DOWN button to select
Blackout (fixture blacks out if DMX signal stops) or Hold (fixture continues to obey the last
command it received Via DMX if DMX signal stops), press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN button to view
the DMX channel value. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select
Pan Invert, Tilt Invert, Color Invert or P/T Feedback.
12E

Pan Invert
To select Pan Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal) or Yes (pan invert), press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
Tilt Invert
To select Tilt Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal) or Yes (tilt invert), press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
Color Invert
To select Color Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal) or Yes (color invert), press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
P/T Feedback
To select P/T Feedback, press the ENTER button to confirm. Use the UP/DOWN button to select No
(Pan or tilt’s position will not feedback while out of step) or Yes (Feedback while pan/tilt out of step),
press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle
30 seconds to exit menu mode.
Lamp Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select
Lamp On/Off or State/Power on.
Lamp On/Off
To select Lamp On/Off, press the ENTER button to confirm. Use the UP/DOWN button to select Off
(lamp off) or On (lamp on), press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
13E

State/Power On
To select State/Power On, press the ENTER button to confirm. Use the UP/DOWN button to select
Off (Lamp off while power on) or On (Lamp on while power on), press the ENTER button to store.
Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Display Settings
Enter menu mode, select Display Settings, press the ENTER button to confirm, use the UP/DOWN
button to select Display Invert, Backlight Intensity or Temperature Unit.
Display Invert
Select Display Invert, press the ENTER button to confirm, present mode will blink on the display, use
the UP/DOWN button to select No (normal display) or Yes (invert display), press the ENTER button
to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
Backlight Intensity
Select Backlight Intensity, press the ENTER button to confirm, present mode will blink on the
display, use the UP/DOWN button to adjust backlight intensity from 001 (dark) to 010 (bright), press
the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
Temperature Unit
Select Temperature Unit, press the ENTER button to confirm, present mode will blink on the display,
use the UP/DOWN button to select
℃
or
℉
, press the ENTER button to store. Press the MENU
button back to the last menu or let the unit idle 30 seconds to exit menu mode.
F ixture Test
Enter menu mode, select F ixture Test, press the ENTER button to confirm, use the UP/DOWN
button to select Auto Test or Manual Test
14E

Auto Test
Select Auto Test, press the ENTER button to confirm, the unit will run built-in programs to
automatically test pan, tilt, color, gobo, gobo rotation, prism, prism rotation, dimmer, shutter, zoom,
focus, frost, and etc. Press the MENU button back to the last menu or exit menu mode after auto
test.
Manual Test
Select Manual Test, press the ENTER button to confirm, the present channel will show on the
display, use the UP/DOWN button to select channel, press the ENTER button to confirm, then use
the UP and DOWN button to adjust the value, press the ENTER button to store, the fixture will run
as the channel value indicates. Press the MENU button back to the last menu or exit menu mode
idling 30 seconds.
(All channels value will become 0 after exiting Manual Test menu)
Fixture Information
Enter menu mode, select Fixture Information, press the ENTER button to confirm, use the
UP/DOWN button to select Fixture Use Time, Lamp Use Hour, Lamp Time Reset, Temperature,
Fan State, USB Upgrade File, Firmware Version, RDM UID or Error Logs.
Fixture Use Time
Select Fixture Use Time, press the ENTER button to confirm, fixture use time will show on the
display, press the MENU button to exit.
Lamp Use Hour
Select Lamp Use Hour, press the ENTER button to confirm, present mode will blink on the display,
use the UP/DOWN button to set the password 050, press the ENTER button to confirm and lamp
use time in Work Mode, Sleep Mode or Sleep Ratio can be viewed, press the ENTER button to
confirm. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu
mode.
15E

Lamp Time Reset
Select Lamp Time Reset, press the ENTER button to set the passcode 050 to reset lamp time, press
the MENU button to exit.
Temperature
Select Temperature, press the ENTER button to confirm, fixture temperature will show on the
display, press the MENU button to exit.
Fan State
Select Fan State, press the ENTER button to confirm, fan state will show on the display, press the
ENTER button to confirm, use the UP/DOWN button to select Base Fan1, Base Fan2, Lamp Fan1,
Lamp Fan2, Lamp Fan3, Head Fan1, Head Fan2 or Head Fan3, press the ENTER button to confirm.
Press the MENU button back to the last menu or exit menu mode idling 30 seconds.
USB Upgrade File
Select USB Upgrade File, press the ENTER button to confirm, USB upgrade file will show on the
display, press the MENU button back to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on the
display, press the MENU button back to exit.
RDM UID
Select RDM UID, press the ENTER button to confirm, RDM UID will show on the display, press the
MENU button back to exit.
Error Logs
Select Error Logs, press the ENTER button to confirm, use the UP/DOWN button to select Fixture
Errors or Reset Error Log, press the ENTER button to confirm. Select Reset Error Log, press the
ENTER button to confirm, use the UP/DOWN button to select No or Yes, press the ENTER button to
confirm. Select Yes, press the ENTER button to confirm, use the UP/DOWN button to set the
password 050 to reset error log. Press the MENU button back to the last menu or exit menu mode
16E

idling 30 seconds.
Reset Functions
Enter menu mode, select Reset Functions, press the ENTER button to confirm, use the UP/DOWN
button to select Pan/Tilt Reset, Effect Reset or All Reset.
Pan/Tilt Reset
Select Pan/Tilt Reset, press the ENTER button to confirm, use the UP/DOWN button to select No or
Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle 30 seconds to exit menu mode.
Effect Reset
Select Effect Reset, press the ENTER button to confirm, use the UP/DOWN button to select No or
Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle 30 seconds to exit menu mode.
All Reset
Select All Reset, press the ENTER button to confirm, use the UP/DOWN button to select No or Yes,
press ENTER button to store. Press the MENU button to exit.
Special Functions
Factory Restore
Select Factory Restore,press the ENTER button to confirm, use the UP/DOWN button to select No
(normal) or Yes (the fixture will reset to factory settings), press ENTER button to store. Press the
MENU button to exit.
17E

RDM FUNCTIONS
Select the MANUFACTURER menu to display the manufacturer of the fixture.
Select the SOFTWARE VERSION menu and the program version number of the fixture will be
displayed.
Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
Select the DEVICE LABEL menu to change the model of the fixture.
Select the DMX PERSONALITY menu to set the channel mode of the fixture (19/21 channel).
Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the
fixture.
Select the DEVICE HOURS menu to display the running time of the fixture.
Select the LAMP HOURS menu to display the running time of the lamp.
Select the LAMP STATE menu to turn on/off the lamp.
Select the PAN INVERT menu and the fixture will run the pan invert mode.
Select the TILT INVERT menu and the fixture will run the tilt invert mode.
Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be displayed. When
WARM RESET is selected, the fixture will start a warm reset, and exit when COLD RESET is selected.
5.2 Home Position Adjustment
Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into
offset mode to adjust the home position. Select the function by the ENTER button. Use the
UP/DOWN button to choose the submenu, press the ENTER button to store and automatically
return to the last menu. Press MENU button to exit.
18E

Pan—pan home position adjustment
Enter offset mode, Select Pan, press the ENTER button to confirm, the present position will blink on
the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button
to store. Press the MENU button to exit.
Tilt—Tilt home position adjustment
Enter offset mode, Select Tilt, press the ENTER button to confirm, the present position will blink on
the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button
to store. Press the MENU button to exit.
Color—Color home position adjustment
Enter offset mode, Select Color, press the ENTER button to confirm, the present position will blink
on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER
button to store. Press the MENU button to exit.
Gobo —Gobo home position adjustment
Enter offset mode, Select Gobo, press the ENTER button to confirm, the present position will blink
on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER
button to store. Press the MENU button to exit.
19E
Table of contents
Other ACME Lighting Equipment manuals

ACME
ACME ANIMA C User manual

ACME
ACME SABER HYBRID PRO User manual

ACME
ACME V Inground VI-10QW User manual

ACME
ACME COMET User manual

ACME
ACME TRACK 10 User manual

ACME
ACME MP-12FC User manual

ACME
ACME BIG BANG User manual

ACME
ACME LED-256D-10W User manual

ACME
ACME DIABOLO 500 User manual

ACME
ACME LED-900 A User manual

ACME
ACME RAYZOR HYBRID User manual

ACME
ACME IM-250 SP User manual

ACME
ACME LIGHT PANEL 1000 User manual

ACME
ACME Xperior 700SZ Spot User manual

ACME
ACME IL-2420 II User manual

ACME
ACME Thunderstruck LP-2304 User manual

ACME
ACME BOOTES User manual

ACME
ACME Spider FC User manual

ACME
ACME ASTRO LED-256D User manual

ACME
ACME Thunder User manual