V2 CITY11 User manual

ENGLISH
- 7 -
IMPORTANT REMARKS
For any installation problem please contact our Customer Service
atthenumber+39-0172.812411operatingMondaytoFriday
from8:30to12:30andfrom14:00to18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
mPlease read this instruction manual very carefully
before installing and programming your control unit.
• Thisinstructionmanualisonlyforqualiedtechnicians,who
specialize in installations and automations.
• Thecontentsofthisinstructionmanualdonotconcerntheend
user.
• Everyprogrammingand/oreverymaintenanceserviceshould
be done only by qualied technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinerysafety.electricalequipment
ofmachines,part1:generalrules)
EN 12445 (Safeuseofautomatedlockingdevices,test
methods)
EN 12453 (Safeuseofautomatedlockingdevices,
requirements)
• Theinstallermustprovideforadevice(es.magnetotermical
switch)ensuringtheomnipolarsectioningoftheequipment
fromthepowersupply.Thestandardsrequireaseparationof
thecontactsofatleast3mmineachpole(EN60335-1).
• Aftermakingconnectionsontheterminalboard,useone
hoseclamptoxdangerousvoltagewiresneartheterminal
boardandanotherhoseclamptoxsafetylowvoltagewires
usedforaccessoriesconnection;thisway,incaseofaccidental
detachmentofaconductingwire,dangerousvoltagepartswill
notcomeintocontactwithsafetylowvoltageones.
• TheplasticcasehasanIP55insulation;toconnectexibleor
rigidpipes,usepipettingshavingthesameinsulationlevel.
• Installationrequiresmechanicalandelectricalskills,thereforeit
shallbecarriedoutbyqualiedpersonnelonly,whocanissue
theComplianceCerticateconcerningthewholeinstallation
(EECMachineDirective2006/42/CEE,AnnexIIA).
• Theautomatedvehiculargatesshallcomplywiththefollowing
rules:EN13241-1,EN12453,EN12445aswellasanylocal
ruleinforce.
• Alsotheautomationupstreamelectricsystemshallcomplywith
thelawsandrulesinforceandbecarriedoutworkmanlike.
• Thedoorthrustforceadjustmentshallbemeasuredbymeans
ofapropertoolandadjustedaccordingtothemax.limits,
whichEN12453allows.
• Connecttheearthingleadofthemotorstotheelectricitygrid
earth system.
• Observeallnecessaryprecautions(e.g.anti-staticbracelet)for
handlingpartssensitivetoelectrostaticdischarges.
DECLARATION OF CONFORMITY
V2S.p.A.herebydeclarethatCITY11productsconformtothe
essentialrequirementsestablishedinthefollowingdirectives:
• 2004/108/CEE(EMCDirectiveinaccordancewithstandards
EN61000-6-2,EN61000-6-3+EN50336)
• 2006/95/CEE(LowVoltageDirectiveinaccordancewith
standardsEN60335-1+EN60335-2-103)
• 99/05/CEE(RadioDirectiveinaccordancewithstandard
EN301489-3)
• DirectiveROHS22011/65/CE
Racconigi,12/01/2010
V2S.p.A.legalrepresentative.egaledellaV2S.p.A.
Cosimo De Falco
TECHNICAL SPECIFICATIONS
Powersupply 230V/50Hz 120V/60Hz
Maxmotorsload 700W 700W
Maxaccessoriesload24V 10W 10W
Workingtemperature -20 ÷ +60 °C -20 ÷ +60 °C
Protectionfuse F1 = 5A delayed F1 = 8A delayed
Dimensions 170 x 185 x 70 mm
Weight 1200g
Protection IP55

ENGLISH
- 8 -
DESCRIPTION OF THE CONTROL UNIT
TheCITY11controlunitisaninnovativeV2productguaranteeing
safetyandreliabilityforswinggateautomation.
TheCITY11designhasbeenaimedatcreatingaproductwhich
adaptstosuitallneeds,thusobtaininganextremelyversatile
controlunitsatisfyingallthenecessaryrequirementsfora
functionalandefcientinstallation.
• 230V-50Hzor120V-60Hzpowersupplies,dependingonthe
model,for2singlephasemotors(700Wglobal).
• Outputfor12Velectriclock.
• Inputforkeyswitchorpush-button.
• Inputforsafetyphotocell.
• Inputforsafetyedge,capableofhandlingstandardedges
withswitchnormallyclosedandconductiverubberedgeswith
nominalresistanceof8.2kOhms.
• Pre-openingsafetydevicetesting.
• Dip-switchprogrammableoperationallogic.
• Adjustmentofmotorpowerandoperationtimebymeansofa
trimmer.
• Quickplug-inconnectorforinsertingaMRseriesreceiver.
• LEDmonitoringofinputs.
• Courtesylightoutput.
• IP55casing
INSTALLATION
Installationofthecontrolunit,thesafetydevicesandaccessories
mustbeperformedwiththepowersupplydisconnected.
POWER SUPPLY
Thecontrolunitmustbepoweredbymeansofa230V-50Hz
or120V-60Hzpowerline,dependingonthemodel,protected
byadifferentialmagnetothermalswitchincompliancewithlegal
regulations.
ConnectthepowercablestothecontrolunitLand Nterminals.
MOTORS
ThecontrolunitcancontroloneortwoasynchronousACmotors.
Ifthecontrolunitisusedtocontrolonlyonemotor,thenthis
mustbeconnectedtotheterminalsrelatingtomotor1.
Connectthecablesformotor1asfollows:
• OpeningcabletoterminalK3
• ClosingcabletoterminalK5
• CommonreturncabletoterminalK4
• Start-upcapacitorbetweenterminalsK3 and K5
Connectthecablesformotor2(ifpresent)asfollows:
• OpeningcabletoterminalK6
• ClosingcabletoterminalK8
• CommonreturncabletoterminalK7
• Start-upcapacitorbetweenterminalsK6 and K8
PHOTOCELLS
Thecontrolunithasa24VACpowersupplyforphotocellswith
switchnormallyclosed,andcanperformanoperationaltest
beforetostartingthegateopeningprocedure.
Thephotocellcanbeusedwithtwosettings:
1. Photocell always active:
Interventionofthephotocellduringopeningorclosingcauses
thegatetostop.Whenthephotocellrestores,thegatere-
opens completely.
2. Photocell NOT active during opening:
Interventionofthephotocellduringopeningisignored.
Interventionofthephotocellduringclosingcausesthegateto
re-open completely.
Independentlyofthesettingselected,whenthegateispaused
whileopening,thetimecountforanyautomaticre-closurewill
onlystartafterthephotocellrestores.
• Connectthephotocelltransmitterpowercablesbetween
terminals L8 (GND)andL9 (+)onthecontrolunit.
• Connectthephotocellreceiverpowercablesbetweenterminals
L8 (GND)andL7 (+)onthecontrolunit.
• ConnectthephotocellreceiveroutputbetweenterminalsL4
and L6 on the control unit.
SAFETY EDGES
Thecontrolunithasaninputforcontrollingsafetyedges;this
inputiscapableofcontrollingstandardedgeswithswitch
normallyclosedandconductiverubberedgeswithnominal
resistanceof8.2kOhms.
Edgescanbeusedwithtwosettings:
1. Edge always active:
Interventionoftheedgeduringopeningorclosingcauses
inversionofthedirectionofmovementinordertofreethe
bodythatcausedtheedgetointervene.Thegatestopsafter
approx. 3 seconds.
2. Edge NOT active during opening:
Interventionoftheedgeduringopeningisignored.
Interventionoftheedgeduringclosingcausesthegateto
re-open completely.
Independentlyofthesettingsselected,anysubsequentautomatic
re-closurewillbecancelled.
Standard edge with switch normally closed: connecttheedge
cablesbetweenterminalsL5 and L6 on the control unit.
InordertosatisfytherequirementsofstandardEN12978,it
isnecessarytoinstallsafetyedgeswithacontrolunitwhich
constantlymonitorscorrectoperation.Ifcontrolunitsareused
withtheoptionofrunningtestsbymeansofinterruptingthe
powersupply,connectthecontrolunitpowersupplycables
betweenterminalsL8(GND)andL9(+).
Conductive rubber edge:connecttheedgecablesbetween
terminals L5 and L6 on the control unit.
mPLEASE NOTE: operational testing on edges is
reserved for standard edges (only if equipped with suitable
control units).
DO NOT enable testing if conductive rubber edges are used
or standard edges used without a suitable control unit for
controlling function.

ENGLISH
- 9 -
COURTESY LIGHT
Thisoutputhasanormally-opencleancontactrelaywhichcloses
forapprox.1secondatthestartofanopeningphase.
Thisswitchmaybeusedtoactivateacourtesylighttimer(max.
load:230V-4A).
PLEASE NOTE:Ifthereisnotimer,thecourtesylightcanbe
controlledusingchannel4ofreceiverMR:bistableortimer
programmablechannel(readtheinstructionsforthereceiverMR
thoroughly).
TheswitchisonterminalsK1 and K2.
BLINKER
Thecontrolunitprovidesfortheuseofa230V-40Wor
120V-40Wblinkerwithbuilt-inintermittence.
Connect the cables to terminals K9 and K10.
ELECTRIC LOCK
A12Velectriclockcanbemountedonthegatetoensureagood
closureoftheshutters.
Theelectriclockisactivatedforaxedtimeof1.5seconds.
Thelockadvancetimeisadjustablefrom0.2to0.5seconds
(dip-switch1)
ConnectthecablesoftheelectriclockbetweenterminalsL10 and
L11ofthecontrolunit.
START INPUT
TheSTARTinputispresetforconnectingdeviceswiththeswitch
normally open.
Functiondependsonthemodeofoperationsetbymeansofdip-
switch4.
Step mode
Subsequent Start command cause, in order:
openinggstop gclosure gstop
“Inversion” mode
Startduringopeningcausesclosure.
Startduringclosurecausesopening.
Startwiththegateopenalwaysresultsinclosure;the only case
wherethisdoesnotoccurimmediatelyiswhenautomaticclosure
isenabledandstartwhileopeningisnotaccepted:inthisspecic
case,startmakesthepausetimecountstartfromzero,after
whichthegatewillbere-closed.
InbothmodesitispossibletodisabletheStartcommandduring
gateopeningbymeansof
dip-switch3.
Connectthestartinputcontroldevicecablesbetweenterminals
L1 and L6 on the control unit.
PEDESTRIAN START
Withthegateclosed,thepedestrianstartcommandcausespartial
opening(approx.halfway)ofthegateleafconnectedtomotor1.
Subsequentpedestrianstartcommandswillfunctionaccordingto
steplogic.
Duringapedestriancycle,thestartcommandresultsinthe
completeopeningofbothgateleaves.
Connectthepedestrianstartinputcontroldevicecablesbetween
terminals L2 and L6 on the control unit.
STOP
TheSTOPinputisintendedfordeviceswiththeswitchnormally
closed.
TheSTOPcommandcausestheimmediatestopofthegate.
AsubsequentSTARTcommandactivatesthegateintheopposite
directionofmovement.
IftheSTOPcommandisgivenduringopeningorpause,then
therewillbenosubsequentautomaticre-closure.
Connectthestopinputcontroldevicecablesbetweenterminals
L3 and L6 on the control unit.
EXTERNAL ANTENNA
Itisrecommendedtheexternalantennabeusedinorderto
guaranteemaximumradiocapacity.
Connect the antenna hot pole to terminal A1ofthecontrolunit
andthebraidingtoterminalA2
PLUG-IN RECEIVER
Thecontrolunitissuitableforplugging-inanMRseriesreceiver.
mPLEASE NOTE: Pay the utmost attention to the
direction of insertion of plug-in modules.
TheMRreceivermodulehas4channels,eachwithanassociated
commandofthecontrolunit:
• CHANNEL1gSTART
• CHANNEL2gPEDESTRIANSTART
• CHANNEL3gSTOP
• CHANNEL4gCOURTESYLIGHTS
mPLEASE NOTE: Read the instructions supplied with the
MR receiver thoroughly for details on programming the 4
channels and the operational logic

ENGLISH
- 10 -
LOCK
1 2 3 4 5 6 7 8 9 10 11 12
RECEIVER
L1 L2
A1
POWER WORK PAUSE DELAY
A2
L3 L4 L5 L6 L7 L8 L9 L10 L11 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 N mains L
ANT
START
START STOP EDGE
overload
mains
START P. PHOTO
STOP
START P.
PHOTO
(Photo / Edge Test)
EDGE
COM
24VAC - 3W
GND
OPEN
COM
CLOSE
OPEN
LAMP
Max 40W
NEUTRAL
PHASE
COM
CLOSE
24VAC
COURTESY
LIGHT
CONTACT
M1 M2
ELECTRICAL CONNECTION
A1 Antenna
A2 Antenna shield
L1 Openingcommandforastandardconnectiondevice
withswitchnormallyopen.
L2 Pedestrianopeningcommandforastandard
connectiondevicewithswitchnormallyopen.
L3 STOPcommand.N.C.switch
L4 Photocell.N.C.switch
L5 Edge.SwitchN.C.orresistiverubberedge
L6 Commandscommon(-)line
L7 - L8 24VACpoweroutputforphotocellsandother
accessories
L8 - L9 PowersupplyforfunctionaltestTXphotocell
L10 - L11 12V electric lock
K1 - K2 Courtesylighttimeractivationswitch
K3 Motor1open
K4 Motor1common
K5 Motor1close
K6 Motor2open
K7 Motor2common
K8 Motor2closed
K9 - K10 230V - 40W / 120V - 40W blinker
N230V/120Vpowersupply-neutral
L230V/120Vpowersupply-phase
mPLEASE NOTE: If not used, the normally closed
inputs (STOP, PHOTO, EDGE) must be jumpered with the
commands common line COM (-)

ENGLISH
- 11 -
CABLE GLAND ASSEMBLY
Thecasingcanaccept4cableglandsinthespecialeasy-break
housings.Thetypeofcableglandisindicatedinthegure.
mPLEASE NOTE:
• Removetheelectroniccircuitboardbeforedrillthecasing.
• Drillthecontainerusingasuitablysizedcutter,accordingtothe
dimensionsofthecablegland.
• Fixthecableglandsusingthespecialnuts.
PG9 - PG11
PG9 - PG11 - PG16
CONTROL UNIT INDICATORS (LEDs)
ThehighlightedboxesindicatethestateoftheLEDswhenthegateisresting.
ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
Thepowerandoperatingtimesmaybeadjustedbymeansof4
trimmers located on the control unit:
mPLEASE NOTE: it is recommended that operating times
be set with the slow down function disabled (DIP 5 OFF).
mWARNING: the adjustment of times has to be made
when the gate is still
POWER
MIN MAX
WORK 50”
18”
2”
2”
45”
PAUSE 150”
30”
2”
2”
90”
DELAY 90”
15”
0
0
45”
POWER:motorpower
WORK:motoroperatingtime
(2-50seconds)
PAUSE:pausetimebefore
automatic re-closure
(2-150seconds).
DELAY:timedelaybetweenthe
twogateleaves(0-90seconds).
LED ON OFF
START STARTinputclosed STARTinputopen
START P. STARTP.inputclosed STARTP.inputopen
STOP STOPinputclosed STOPinputopen
PHOTO PHOTOinputclosed PHOTOinputopen
EDGE Standard edge
EDGEinputclosed(edgenotpressed) EDGEinputopen(edgepressed)
Resistive rubber edge
EDGEinputclosed(edgepressed) EDGEinputopen(fault)
EdgeNOpressed:8K2betweenEDGEinputand
common(-)
mains Controlunitpowered-up ControlunitNOTpowered-up
overload Accessorypowersupplyoverload Accessorypowersupplywithinnormaloperationallimits

ENGLISH
- 12 -
DIP FUNCTION SETTING DESCRIPTION
1
Pre-ashing,
backlash,
electric lock
advance
ON Enabled
functions
Theashinglightlightsupfor3sec.beforethemotorsarestartedinopening.
After1secondofpre-ash,thebacklashisactivatedfor2seconds.
After0.5secondsofbacklashtheelectriclockisactivated
OFF -Preashingdisabled.Waterhammerdisabled.
0.3secondsofelectriclockadvance
2Automatic closure
ON Enabled ThegateisclosedautomaticallyaftertheperiodoftimesetbythePAUSE
trimmer
OFF Disabled Oncompletionoftheopeningstep,thegateremainsopen.Itisnecessaryto
instructclosurewithanotherSTARTcommand
3Startduring
opening
ON Not accepted AnySTARTcommandissuedduringopeningisignored
OFF Accepted AnySTARTcommandissuedduringopeningisaccepted
4Operationallogic
ON Inversion Startduringopeningcausesclosure.
Startduringclosurecausesopening.
OFF Step Commandssubsequenttostartingcause,inorder:
open gstop gclose gstop...
5Slowdownand
nal push
ON Enabled Attheendofeachopeningandclosingphasethemotorsslowdown
for2seconds.Thenalpushlastsfor1second
OFF Disabled
6Startoff ON Disabled Atthestartofeachopeningandclosingstep,themotorsarestartedat
maximumpower
OFF Enabled
7Anti-slip
ON Disabled ThetimeusedforopeningorclosurewillalwaysbethevaluesetbytheWORK
trimmer,evenifthepreviousoperationhasbeeninterruptedbeforetheexpiry
ofsuchtime.
OFF Enabled Whenanopening(orclosing)operationisinterruptedbeforeexpiryofthe
settime(forexampleduetotheinterventionofoneofthesafetydevicesor
duetoastartcommand),thedurationofthesubsequentclosing(oropening)
operationwillnotbethatsetbytheWORKtrimmer,butwillbeequaltothe
timeeffectivelyelapsed,plusashortsupplementaltimeinordertocompensate
fortheinertiaofthegate.
8Photocell
ON Alwaysactive Interventionofthephotocellduringopeningorclosingcausesthegateto
stop.Whenthephotocellrestores,thegatere-openscompletely.
OFF NOTactiveduring
opening
Interventionofthephotocellduringopeningisignored.Interventionofthe
photocellduringclosingcausesthegatetore-opencompletely.
9Photocell test
ON Enabled Thecontrolunitperformsaphotocelloperationaltestbeforestartingeach
openingorclosingoperation.Ifthephotocellsarenotoperatingcorrectly,the
gatedoesnotbegintomoveandthelightashesforapprox.8seconds.
PLEASE NOTE: connect the photocell TX correctly
OFF Disabled
10 Safetyedgetype
ON Conductive rubber
edge
Selectthisoptionifusingconductiverubberedgeswithnominalresistanceof
8K2.
OFF Standard or optical
edge
Selectthisoptionifusingstandardedgeswithswitchnormallyclosedor
opticaledges.
11 Safetyedge
ON Alwaysactive Interventionoftheedgeduringopeningorclosingcausesinversionofthe
directionofmovementinordertofreethebodythatcausedtheedgeto
intervene.Thegatewillbestoppedafterapprox.3seconds.
OFF NOTactiveduring
opening
Interventionoftheedgeduringopeningisignored.Interventionoftheedge
duringclosingcausesthegatetobere-openedcompletely.
12 Safetyedgetest
ON Enabled Thecontrolunitperformsanoperationaltestontheedgesbeforestarting
eachopeningorclosingoperation.Iftheedgesarenotoperatingcorrectly,the
gatedoesnotbegintomoveandthelightashesforapprox.8seconds.
DO NOT enable testing if conductive rubber edges are used or standard
edges are used without a suitable control unit for controlling function.
OFF Disabled
PROGRAMMING THE OPERATIONAL LOGIC
Itispossibleforthecontrolunittouseseveraldifferentoperationallogicstates,bysimplymovingthedip-switcheslocatedonthecard.
Thefunctionsassociatedwitheachindividualdip-switcharelistedbelow.

FRANÇAIS
- 13 -
CONSEILS IMPORTANTS
Pourtoutprécisiontechniqueouproblèmed’installationV2
disposed’unServiceClientsàVotredispositiondulundiau
vendredi de 8:30 à 12:30 et de 14:00 heures à 18:00 heures. au
numéro +39-0172.812411
V2 S.p.A. se réserve le droit d’apporter d’éventuelles
modications au produit sans préavis; elle décline en outre
toute responsabilité pour tous types de dommages aux
personnes ou aux choses dus à une utilisation imporopre ou
à une mauvaise installation.
mAvant de proceder avec l’installation et la
programmation, lire attentivement les notices.
• Cemanueld’instructionestdestinéàdestechniciensqualiés
dans le domain des automatismes.
• Aucunedesinformationscontenuesdanscelivretpourraêtre
utile pour le particulier.
• Tousoperationsdemaintenanceouprogramationdoiventêtre
faitesàtraversdetechniciensqualiés.
L’AUTOMATION DOIT ÊTRE RÉALISÉE CONFORMÉMENT AUX
DISPOSITIFS NORMATIFS EUROPÉENS EN VIGUEUR
EN 60204-1 (Sécurité de la machinerie. Équipement
électriquedesmachines,partie1:réglesgénérales).
EN 12445 (Sécuritédansl’utilisationdefermetures
automatisées,méthodesd’essai).
EN 12453 (Sécuritédansl’utilisationdefermetures
automatisées,conditionsrequises).
• L’installateurdoitpourvoiràl’installationd’undispositif
(ex.interrupteurmagnétothermique)quiassurelacoupure
omnipolairedel’équipementduréseaud’alimentation.
Lanormerequiertuneséparationdescontactsd’aumoins
3mmpourchaquepôle(EN60335-1).
• Quandonaeffectuélesbranchementsàlaborniere,ilfaut
mettre des bandes sur les conducteurs à tension qui se
trouvent en proximité de la borniere et sur les conducteurs
pourlebranchementdespartiesexternes(accessoires).
Decettemaniere,encasdedétachementd’unconducteur,on
évite que les partie en tension puissent aller en contact avec les
partiesàfaibletensiondesécurité.
• Pourlaconnexiondetubesrigidesouexiblesutiliserdes
raccordementspossédantleIP55niveaudeprotection.
• L’installationrequiertdescompétencesenmatièred’électricité
etmécaniques;doitêtrefaiteexclusivementpartechniciens
qualiésenmesurededélivrerl’attestationdeconformitépour
l’installation(Directive2006/42/CEE,-IIA).
• Ilestobligatoireseconformerauxnormessuivantespour
fermeturesvéhiculairesautomatisées:EN13241-1,EN12453,
EN 12445 et à toutes éventuelles prescriptions nationales.
• Mêmel’installationélectriqueouonbranchel’automatisme
doitrépondreauxnormesenvigueuretêtrefaitàrèglesde
l’art.
• Larégulationdelaforcedepousséeduvantaildoitêtre
mesuréeavecoutilspécialetrégléeselonlesvaleursmaxi
admis par la norme EN 12453.
• Brancherlecâbledeterredesmoteursàl’installationdemiseà
laterreduréseaud’alimentation.
• Précautionsnécessairesàprendre(parexemplebrassard
antistatique)pourmanipulerlespartiessensiblesauxdécharges
électrostatiques.
DÉCLARATION DE CONFORMITÉ
V2S.p.A.déclarequelesproduitsCITY11sontconformentaux
qualités requises essentielles xées par les directives suivantes :
• 2004/108/CEE(DirectiveEMCsuivantlesnormes
EN61000-6-2,EN61000-6-3+EN50336)
• 2006/95/CEE(DirectiveBassetensionsuivantlesnormes
EN60335-1+EN60335-2-103)
• 99/05/CEE(DirectiveRadiosuivantlesnormesEN301489-3)
• DirectiveRoHS22011/65/CE
Racconigi,12/01/2010
LereprésentantdûmenthabilitéV2S.p.A.
Cosimo De Falco
CARACTÉRISTIQUES TECHNIQUES
Alimentation 230V/50Hz 120V/60Hz
Chargemaxmoteur 700W 700W
Chargemaxaccessoires
24V
10W 10W
Températuredetravail -20 ÷ +60 °C -20 ÷ +60 °C
Fusible de protection F1 = 5A delayed F1 = 8A delayed
Dimensions 170 x 185 x 70 mm
Poids 1200g
Protection IP55