manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VeEX
  6. •
  7. Test Equipment
  8. •
  9. VeEX DS3 BERT User manual

VeEX DS3 BERT User manual

This manual suits for next models

1

Other VeEX Test Equipment manuals

VeEX VePAL TX300 User manual

VeEX

VeEX VePAL TX300 User manual

VeEX VePAL TX300 User manual

VeEX

VeEX VePAL TX300 User manual

VeEX LX100 Guide

VeEX

VeEX LX100 Guide

VeEX UX400 User manual

VeEX

VeEX UX400 User manual

VeEX MTTplus User manual

VeEX

VeEX MTTplus User manual

VeEX MTX150 Series User manual

VeEX

VeEX MTX150 Series User manual

VeEX Fiber Scope Inspector User manual

VeEX

VeEX Fiber Scope Inspector User manual

VeEX VePAL TX300 User manual

VeEX

VeEX VePAL TX300 User manual

VeEX FX120 User manual

VeEX

VeEX FX120 User manual

VeEX WiFi Air Expert Series User manual

VeEX

VeEX WiFi Air Expert Series User manual

VeEX V-SAM VePAL V300 User manual

VeEX

VeEX V-SAM VePAL V300 User manual

VeEX VePAL TX300M User manual

VeEX

VeEX VePAL TX300M User manual

VeEX FX30 User manual

VeEX

VeEX FX30 User manual

VeEX CX380C User manual

VeEX

VeEX CX380C User manual

VeEX NET-BOX User manual

VeEX

VeEX NET-BOX User manual

VeEX VePAL TX320s User manual

VeEX

VeEX VePAL TX320s User manual

VeEX TX300s User manual

VeEX

VeEX TX300s User manual

VeEX VePAL TX300 User manual

VeEX

VeEX VePAL TX300 User manual

VeEX OTDR FX150+ Series User manual

VeEX

VeEX OTDR FX150+ Series User manual

VeEX MX100 Series Guide

VeEX

VeEX MX100 Series Guide

VeEX MTTplus User manual

VeEX

VeEX MTTplus User manual

VeEX RXT-6200 User manual

VeEX

VeEX RXT-6200 User manual

VeEX MPX100 User manual

VeEX

VeEX MPX100 User manual

VeEX MTT-14B User manual

VeEX

VeEX MTT-14B User manual

Popular Test Equipment manuals by other brands

Ambit P.F. Series instruction manual

Ambit

Ambit P.F. Series instruction manual

Megger BMM500 Series user guide

Megger

Megger BMM500 Series user guide

RJG Lynx Sensor Tester operating instructions

RJG

RJG Lynx Sensor Tester operating instructions

Mark-10 TT02 Series user guide

Mark-10

Mark-10 TT02 Series user guide

Martel 3001 Operator's manual

Martel

Martel 3001 Operator's manual

ElproSys DiagProg4 instruction manual

ElproSys

ElproSys DiagProg4 instruction manual

Redtech TRAILERteck T05 user manual

Redtech

Redtech TRAILERteck T05 user manual

Venmar AVS Constructo 1.0 HRV user guide

Venmar

Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions SafetyPAT operating manual

Test Instrument Solutions

Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments HI 38078 instruction manual

Hanna Instruments

Hanna Instruments HI 38078 instruction manual

Kistler 5495C Series instruction manual

Kistler

Kistler 5495C Series instruction manual

Waygate Technologies DM5E Basic quick start guide

Waygate Technologies

Waygate Technologies DM5E Basic quick start guide

StoneL DeviceNet CK464002A manual

StoneL

StoneL DeviceNet CK464002A manual

Seica RAPID 220 Site preparation guide

Seica

Seica RAPID 220 Site preparation guide

Kingfisher KI7400 Series Training manual

Kingfisher

Kingfisher KI7400 Series Training manual

Kurth Electronic CCTS-03 operating manual

Kurth Electronic

Kurth Electronic CCTS-03 operating manual

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Verification Experts
Quick Reference Guide
VePAL TX300
DS3 BERT
TRANSPORT
VePAL TX300
Quick Reference Guide
DS3 BERT
OTN/10GE/SDH/
PDH test ports
10/100/1000Base-T and
1000Base-X test ports Navigation
Control
Field Replaceable Smart
Li-Ion Battery
7” Color
Touch Screen
Quick Keys
DC
Input
Ethernet
USB
TX300 Test Set
VePAL TX300
Quick Reference Guide
DS3 BERT
The Home menu can be accessed at anytime during operation
by pressing the Home key on the rubber keypad. The screen is
divided into three presentation areas:
Left
Middle
Right
Home Menu
LEDs: Displays soft LEDs associated with Errors
and Alarms
Tools: IP connection status, Advanced IP features
(Net Wiz, WiFi Wiz, VoIP, and IPTV applications),
Fiber Scope, ReVeal EZ Connect
Utilities: Applications (Help, Settings, Files) which
are common to all VePAL handheld test sets
Test Applications specic to the test set (DS1, DS3,
SONET, Ethernet, Fiber Channel, 3.072G Testing,
Advanced Mode)
Start/Stop
Err Inj/Alarm: Tap to insert an error or alarm
Alarm/Err: Pull down menu with buttons for alarm
generation and error injection
DS3 Loop: Activate the loopback



  
VePAL TX300
Quick Reference Guide
DS3 BERT
Allows the user to set up the DS3 interfaces and associated test
parameters prior to running a test.
DS3 Tools Menu
DS3 Pulse Mask
FEAC Tasks
Round Trip Delay
DS3 Menu
DS3 Home Menu
Setup – congure
Interface,
Measurement and
General settings;
Framing, Line
code, Pattern,
Clock source and
Offset options are
also congured in
this screen
Results – view Summary, Analysis, Errors/Alarms, Histogram,
Graph, Signal, and Event Log
Alarm/Error – select the Alarms and Errors type/ow
Tools – Pulse Mask, View Rx Data, Round Trip Delay, ISDN,
VF Tasks
Proles – all have the ability to save proles
VePAL TX300
Quick Reference Guide
DS3 BERT
1. Connect to the DS3 test interface using the BNC connectors
2. Power on the unit
3. From the DS3 Home menu, tap on the Setup menu
4. Congure the Measurements and General settings
Conguration
5. Tap the Interface tab to set up the DS3 interfaces and
associated test parameters prior to running a test.
External Clock: The clock for the transmitter is derived from a 1.5Mbit/s
signal or 1.5MHz BITS clock present on the SMA connector and 1.5Mbit/s
signal present on the RX2 balanced or AUX BNC unbalanced.
Offset: The clock for the transmitter is derived from the internal clock
generator. It can change the offset while measurements are running. Use
numeric keys to increase/decrease the frequency shift up to 0.01 ppm.
Frequency offset: ±50 ppm with 1, 0.1, 0.01 ppm resolution.
Line Code: line code
opons are B3ZS or AMI
Clock Src: Internal,
External (SMA or 2nd RX
for balanced or AUX RX
for unbalanced), From
RX, Oset (±50 ppm)
Measurements:
Mode - xed duraon or
delayed start
Performance Analysis-
None, G.821, G.826, M.2100
Jier - ON or OFF
General: Audible Alarm
and Auto Save sengs
VePAL TX300
Quick Reference Guide
DS3 BERT
To configure fields that
require alpha or alpha-
nu m eri c en t r y, su ch
as Frequency Offset, a
configuration keypad
will appear when the
applicable eld is selected.
6. Tap to return to the previous menu.
7. Congure the Rate.
Tabs for the Timeslot
Selecon are Clear All
and Select All, or tap
the timeslot number
to select an individual
meslot.
Low Rate can be set to
DS3, DS1 or Fraconal
DS1 (Nx64 or Nx56)
DS3 Framing opons are
Unframed, M13, or C-BIT
DS1 Channel options
are 1 to 28; DS1 Framing
opons are Unframed,
D4 (SF), or ANSI T1.107
(ESF)
Conguration (cont’d)
VePAL TX300
Quick Reference Guide
DS3 BERT
8. Congure the Pattern.
9. Tap the Auto-cong button.
−A search for DS3 signals is performed to determine the
signal type, rate, framing, pattern.
INVERT: Inversion of PRBS polarity is also available. Inversion of xed
words is not permitted.
Use the paern drop
down box to select
the test paern. PRBS,
xed words and 32 bit
user dened paerns
are available.
Conguration (cont’d)
Tap . If the
search is successful, a
“Complete” result will
be displayed.
VePAL TX300
Quick Reference Guide
DS3 BERT
10. When the test is started, the screen automatically moves to
the Results, Summary screen.
−Results can be viewed by selecting the following tabs:
Summary, Analysis, Errors/Alarms, Histogram, Graph,
Signal, and Event Log
Summary screen: Provides an overview of any alarms, errors
or signal failures.
Analysis screen: ES, SES, AS, UAS are evaluated and a
Pass/Fail result is displayed in conjunction with path allocation
of between 0.1 and 100%.
Results
VePAL TX300
Quick Reference Guide
DS3 BERT
Errors/Alarms screen: The soft LEDs on screen are arranged
logically and depend on signal hierarchy, structure, payload and
framing selected. The soft LEDs have a tri-color function.
Results (cont’d)
Note: Tapping the individual soft LED will automatically link you to
the applicable results screen, which provides detailed information.
Green: No error or
alarm is present
Red: An error or
alarm condition
is detected and is
currently present
Yellow: Indicates a
history condion
VePAL TX300
Quick Reference Guide
DS3 BERT
Signal screen: Tap the Signal tab to bring up the Frequency
and Level results.
Results (cont’d)
FREQUENCY – the received signal frequency and offset is
measured and displayed.
−45M current: Indicates the frequency of the input signal
−Offset: Indicates the difference between the standard
rate and the rate of the input signal
−Min (ppm): Indicates the difference between the
standard rate and the minimum deviation detected in
the input signal
−Max (ppm): Indicates the difference between the
standard rate and the maximum deviation detected
in the input signal
LEVEL – measures the Peak and Peak-Peak voltage
values of the incoming signal.