manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxby Lighting
  6. •
  7. Lighting Equipment
  8. •
  9. Saxby Lighting Surge PIR Manual

Saxby Lighting Surge PIR Manual

This manual suits for next models

4

Other Saxby Lighting Lighting Equipment manuals

Saxby Lighting Louvre Photocell User manual

Saxby Lighting

Saxby Lighting Louvre Photocell User manual

Saxby Lighting Regen Manual

Saxby Lighting

Saxby Lighting Regen Manual

Saxby Lighting 48700 Manual

Saxby Lighting

Saxby Lighting 48700 Manual

Saxby Lighting 14008 User manual

Saxby Lighting

Saxby Lighting 14008 User manual

Saxby Lighting ALBA SOLAR POST PIR User manual

Saxby Lighting

Saxby Lighting ALBA SOLAR POST PIR User manual

Saxby Lighting 97818 User manual

Saxby Lighting

Saxby Lighting 97818 User manual

Saxby Lighting 78965 User manual

Saxby Lighting

Saxby Lighting 78965 User manual

Saxby Lighting Picco User manual

Saxby Lighting

Saxby Lighting Picco User manual

Saxby Lighting 1818PIR Manual

Saxby Lighting

Saxby Lighting 1818PIR Manual

Saxby Lighting 108750 User manual

Saxby Lighting

Saxby Lighting 108750 User manual

Saxby Lighting Icarus Twin Wall EL-40054 Manual

Saxby Lighting

Saxby Lighting Icarus Twin Wall EL-40054 Manual

Saxby Lighting 74824 Manual

Saxby Lighting

Saxby Lighting 74824 Manual

Saxby Lighting SHIELDPRO CCT 90376 User manual

Saxby Lighting

Saxby Lighting SHIELDPRO CCT 90376 User manual

Saxby Lighting OrionSMART User manual

Saxby Lighting

Saxby Lighting OrionSMART User manual

Saxby Lighting SIGHTPRO 108087 User manual

Saxby Lighting

Saxby Lighting SIGHTPRO 108087 User manual

Saxby Lighting Sight 3 in 1 Manual

Saxby Lighting

Saxby Lighting Sight 3 in 1 Manual

Saxby Lighting Odyssey Bollards ST501228 User manual

Saxby Lighting

Saxby Lighting Odyssey Bollards ST501228 User manual

Saxby Lighting 75145 Manual

Saxby Lighting

Saxby Lighting 75145 Manual

Saxby Lighting Tango User manual

Saxby Lighting

Saxby Lighting Tango User manual

Saxby Lighting 103253 User manual

Saxby Lighting

Saxby Lighting 103253 User manual

Saxby Lighting 43810 Manual

Saxby Lighting

Saxby Lighting 43810 Manual

Saxby Lighting Eris Manual

Saxby Lighting

Saxby Lighting Eris Manual

Saxby Lighting HeroPro CCT Microwave Emergency User manual

Saxby Lighting

Saxby Lighting HeroPro CCT Microwave Emergency User manual

Saxby Lighting Varone 55702 Manual

Saxby Lighting

Saxby Lighting Varone 55702 Manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Surge PIR
78963, 78965, 78967, 78969
Instruction leaflet
Care and Safety
PIR Adjustment
•You have correctly
identified the wires.
•The connections are tight.
•No loose strands have
been left out of the terminals.
Terminal block not included. Installation may require advice from a qualified person. Connect to an approved
outdoor rated terminal block, observing the wiring diagram here:
Wiring
Check that...
V3 06/08/2021
www.saxbylighting.com
EU Manufacturer: 1 Gnarrenburg, 27442
UK Manufacturer: BH17 7BY
Saxby Lighting
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
SUPPLY
NEUTRAL BLUE (N)
GREEN/YELLOW
BROWN(L)
EARTH
SWITCHED LIVE
LIGHT FITTING
Please read in full before test and keep for future reference take care not to over rotate the dials. They do not rotate through
360º for testing in daylight.
Infrared induction mode:
Infrared sensors into infrared sensing mode after first power on,
LUX gear can adjust the open ambient light of load sensors, when the knob
indicator rotation in sun position, the load will open during the day, When
rotation in moon position, the load only open at night.
TIME gear adjust the delay time of sensor work time, when the knob indicator
rotation in “+”position, the most delay time is 8min±2min, when rotation
in “-”position, the shortest delay time is 10sec±5sec.
SENS gear adjust the induction distance of sensor, when the knob
indicator rotation in “+”position, the distance is farthest, when rotation
in “-”position, the distance is shortest.
Manual override mode:
In sensor mode, turn off the power, then turn on within 2-3 seconds, switch to override
mode and the light will stay lit. Turn off the light more than 10 seconds, the light will go
to sensor mode when it is turned on again.
LUX
TIME
SENS
PIR Specification
78963, 78965, 78967 and 78969 are fitted with
PIR motion sensor. The specification is as follows:
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Technical data
Please read these instructions carefully before commencing
any work.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
The external flexible cable or cord of this luminaire cannot
be replaced; if the cord is damaged, the luminaire must be
destroyed.
This product is not suitable for location in or near a marine
environment.
The entire unit gets hot whilst on for a period of time.
This product is supplied with 1 metres of H05RN-F outdoor
grade rubber sheathed cable - ready for connection to an
approved, outdoor rated terminal block which is not
supplied and must be obtained.
This is a floodlight product, and therefore should be
positioned where it will not cause a glare hazard.
Terminal block not included. Installation may require advice
from a qualified person.
This unit must be fitted by a competent and qualified
electrician.
Check the pack and make sure you have all of the parts listed.
To prevent electrocution switch off at mains supply before
installing or maintaining this fitting.
Ensure other persons cannot restore the electrical supply
without your knowledge.
Install in accordance with IEE Wiring regulations and current
Building Regulations.
Supply
Voltage:
Bulb
Type:
220-240V~, 50 Hz
78963 : 10W LED (SMD), 4000K
78965 : 20W LED (SMD), 4000K
78967 : 30W LED (SMD), 4000K
78969 : 50W LED (SMD), 4000K
The light source of this luminaire is not
replaceable; when the light source reaches its
end of life the whole luminaire shall be replaced.
Conformity with all relevant EC Directive
requirements.
Waste electrical products should not be
disposed of with household waste. Please
recycle where facilities exist.Check with your
Local Authority or local store for recycling advice.
This product is not suitable for dimming.
Layout
• The optimum height is between 1m-3m.
Lights can install on the ground and wall or brackets according to actual situation such as installation on the brackets with
hexagonal head screw fixed. And dig the hole on ground or wall with suitable expansion bolt (not provide) fixing according
to light's bracket if install on the ground or wall.
• Cables must be protected using suitable conduit or plastic trunking.
• The mains supply cable must have a minimum cross section area of 1.0mm2.
• Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the
junction box and the light fitting.
• Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
If replacing an existing fitting, make a careful note of the
connections.
Class I product, must be connected to earth.
Installation
•Drill and plug the wall at the marked positions.
•Fix the bracket to the wall using the screws and plugs (not provided). Take care to avoid damaging any
concealed wiring and pipes. The correct fixings should be used for brick or cavity walls.
• Hold the product in position and mark the location of the fixing holes. A minimum of two fixing points must be used.
Ensure the wall is capable of holding the weight of the product. The bracket can be removed from the fitting for
ease of installation.
•Wire as detailed wiring.
•Using the allen key (not supplied), loosen the bolts on the side, and adjust the fitting to the desired position.
Ensure that the cable is not snagged. Re-tighten the bolts.
IP
44
Conformity with all relevant UKCA Directive
requirements.
This product is rated at IP44.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the power needs to be isolated/switched off at the fuse board.
Power Source: 220-240VAC
Power Frequency: 50/60Hz
Rated Load: MAX. 50W
Detection Range: 120º
Detection Distance: 8±2m (<24ºC)(adjustable)
Time Setting: 10±5sec-8±2min. (adjustable)
Ambient Light: 2-2000Lux. (adjustable)
Detection Motion Speed: 0.6-1.5m/s
Working TemperaturePower: -10ºC--+45ºC
Working Humidity: <40%RH
Installation Height: 1-3m
induction area figure:
4m±2m
8m±2m
120º